ABSTRACT
Abstract Background: Central line-associated bloodstream infections (CLABSIs) are among the most epidemiologically relevant health care-associated infections. The aseptic non-touch technique (ANTT) is a standardized practice used to prevent CLABSIs. In a pediatric hospital, the overall CLABSI rate was 1.92/1000 catheter days (CD). However, in one unit, the rate was 5.7/1000 CD. Methods: Nurses were trained in ANTT. For the implementation, plan-do-study-act (PDSA) cycles were completed. Adherence monitoring of the ANTT and epidemiological surveillance were performed. Results: ANTT adherence of 95% was achieved after 6 PDSA cycles. Hand hygiene and general cleaning reached 100% adherence. Port disinfection and material collection had the lowest adherence rates, with 76.2% and 84.7%, respectively. The CLABSI rate decreased from 5.7 to 1.26/1000 CD. Conclusion: The implementation of ANTT helped reduce the CLABSI rate. Training and continuous monitoring are key to maintaining ANTT adherence.
Resumen Introducción: Las infecciones relacionadas con catéteres venosos centrales son unas de las infecciones asociadas a la atención de salud con mayor relevancia epidemiológica. La técnica aséptica «no tocar¼ es una práctica estandarizada que se utiliza para prevenir estas infecciones. En un hospital pediátrico, la tasa de infecciones relacionadas con catéteres venosos centrales fue de 1.92/1000 días de catéter. Sin embargo, en una de las unidades la tasa fue de 5.7/1000 días de catéter. Método: Se capacitaron enfermeras en la técnica aséptica «no tocar¼. Para la implementación se cumplieron ciclos de planificar-hacer-estudiar-actuar (PHEA). Se realizaron seguimiento de la adherencia a la técnica y vigilancia epidemiológica. Resultados: Se logró una adherencia a la técnica aséptica «no tocar¼ del 95% después de seis ciclos. La higiene de manos y la limpieza general alcanzaron un 100% de cumplimiento. La desinfección de los puertos y la recolección de material alcanzaron la menor adherencia, con un 76.2% y un 84.7%, respectivamente. La tasa de infecciones relacionadas con catéteres venosos centrales disminuyó de 5.7 a 1.26 por 1000 días de catéter. Conclusiones: La implementación de la técnica aséptica «no tocar¼ ayudó en la reducción de infecciones relacionadas con catéteres venosos centrales. La capacitación y el seguimiento continuo son clave para mantener el cumplimiento de la técnica.
ABSTRACT
Resumo Objetivo Avaliar o efeito de uma intervenção educativa para enfermeiros para aumentar o conhecimento e as habilidades práticas de manejo de dispositivos de acesso vascular totalmente implantados. Métodos Estudo quase-experimental realizado em um hospital universitário. A intervenção incluiu exposição a um manual de procedimentos seguida de treinamento teórico-prático sete dias depois. Oitenta e um enfermeiros foram avaliados no início do estudo, após autoexposição ao manual e após receberem treinamento teórico-prático. Os participantes foram avaliados quanto ao seu conhecimento e habilidades práticas no gerenciamento de dispositivos de acesso vascular totalmente implantados. Estatísticas descritivas foram realizadas para todas as variáveis. O teste t pareado foi utilizado para examinar se a pontuação média mudou desde a linha de base até a primeira e segunda avaliações de conhecimento, acesso, desacesso e manutenção do cateter. O nível de significância foi definido como 0,05. Resultados Os aumentos médios nas pontuações após a exposição dos enfermeiros ao manual foram de 18,2 pontos para conhecimento, com 16,5 pontos para técnica de acesso, 15,5 para técnica de desacesso e 24,2 para técnica de manutenção do cateter. Após o treinamento teórico-prático, observamos aumento médio de 4,2 pontos para acesso, com 3,9 para desacesso e 4,2 para manutenção do cateter. Conclusão A intervenção educativa para enfermeiros aumentou os escores médios de conhecimentos e habilidades práticas. Ao final da intervenção, 75% dos enfermeiros atingiram pelo menos 33 pontos de 38 para conhecimento e 77%, 77% e 78% obtiveram escores perfeitos para acesso, desacesso e manutenção, respectivamente. A intervenção educativa foi eficaz na melhoria do conhecimento e das habilidades práticas para manejo de dispositivos de acesso vascular totalmente implantados.
Resumen Objetivo Evaluar el efecto de una intervención educativa para enfermeros para aumentar los conocimientos y las habilidades prácticas de manejo de dispositivos de acceso vascular totalmente implantados. Métodos Estudio cuasi experimental realizado en un hospital universitario. La intervención incluyó la exposición a un manual de procedimientos, seguida de una capacitación teórico-práctica siete días después. Se evaluó a 81 enfermeros al comienzo del estudio, después de la autoexposición al manual y después de recibir la capacitación teórico-práctica. Los participantes fueron evaluados respecto a sus conocimientos y habilidades prácticas en la gestión de dispositivos de acceso vascular totalmente implantados. Se realizaron estadísticas descriptivas para todas las variables. Se utilizó el test-t pareado para examinar si el puntaje promedio cambió desde la línea basal hasta la primera y segunda evaluación de conocimientos, acceso, desacceso y mantenimiento del catéter. El nivel de significación fue definido como 0,05. Resultados El aumento promedio de los puntajes después de la exposición de los enfermeros al manual fue de 18,2 puntos en el conocimiento, con 16,5 puntos en la técnica de acceso, 15,5 en la técnica de desacceso y 24,2 en la técnica de mantenimiento del catéter. Después de la capacitación teórico-práctica, observamos un aumento promedio de 4,2 en el acceso, 3,9 en el desacceso y 4,2 en el mantenimiento del catéter. Conclusión La intervención educativa para enfermeros aumentó el puntaje promedio de conocimientos y habilidades prácticas. Al final de la intervención, el 75 % de los enfermeros alcanzó por lo menos 33 puntos de 38 en el conocimiento y el 77 % obtuvo puntaje perfecto en el acceso y en el desacceso y el 78 % en el mantenimiento. La intervención educativa fue eficaz en la mejora de los conocimientos y habilidades prácticas para el manejo de dispositivos de acceso vascular totalmente implantados.
Abstract Objective To evaluate the effect of an educational intervention for nurses to increase knowledge and practical skills of management of totally implanted vascular access devices. Methods A quasi-experimental study conducted in a teaching hospital. The intervention included exposure to a manual of procedures followed by a theoretical-practical training seven days later. Eighty-one nurses were evaluated at baseline, after self-exposure to the manual, and after receiving the theoretical-practical training. Participants were evaluated on their knowledge and practical skills of totally implanted vascular access device management. Descriptive statistics were performed for all variables. Paired t test was used to examine whether the mean score changed from the baseline to first and second assessments of knowledge, access, de-access and maintenance of catheter. Significance level was set to 0.05. Results Mean increases in scores after nurses were exposed to the manual were: 18.2 points for knowledge, 16.5 points for access technique, 15.5 for de-access technique, and 24.2 for catheter maintenance technique. After the theoretical-practical training, we observed a mean increase of 4.2 points for access, 3.9 for de-access and 4.2 for catheter maintenance. Conclusion The educational intervention for nurses increased mean scores of knowledge and practical skills. At the end of the intervention, 75% of the nurses reached at least 33 points out of 38 for knowledge, and 77%, 77%, and 78% had perfect scores for access, de-access, and maintenance, respectively. The educational intervention was effective in improving knowledge and practical skills for management of totally implanted vascular access devices.
ABSTRACT
Objective: to analyze the effectiveness of peripherally inserted central catheter insertion techniques in preventing the occurrence of complications related to this device in newborns. Method: a paired and network systematic literature review and meta-analysis, with its search carried out in seven databases and in the Grey Literature, including randomized and non-randomized clinical trials. The risk of bias was assessed using the Cochrane Risk of Bias 2 and Risk of Bias In Non-randomized Studies of Interventions tools. Certainty of the evidence was assessed by means of the Grading of Recommendations Assessment, Development and Evaluation. A meta-analysis was carried out with the aid of the R statistical program. Results: eight studies with 1,126 newborns were included and six insertion techniques were identified: intracavitary electrocardiogram; intracavitary electrocardiogram associated with ultrasound; ultrasound; formula; anatomical landmark; and modified anatomical landmark. Five techniques significantly decreased primary tip malpositioning when compared to the control ( p <0.05). Intracavitary electrocardiogram significantly and more effectively reduced arrhythmias, general complications and phlebitis; the technique that used a formula also reduced general complications. Infection, infiltration, secondary tip malpositioning, catheter rupture, thrombosis, occlusion and catheter-associated skin lesion were not significantly preventable events. Conclusion: intracavitary electrocardiogram and use of the formula were the most effective techniques in reducing complications.
Objetivo: analizar la efectividad de las técnicas de inserción de catéter central de inserción periférica en la prevención de la aparición de complicaciones asociadas con este dispositivo en recién nacidos. Método: revisión sistemática de la literatura y metaanálisis pareado y en red, la búsqueda se realizó en siete bases de datos y en la literatura gris, se incluyeron ensayos clínicos aleatorizados y no aleatorizados. El riesgo de sesgo se evaluó mediante las herramientas Cochrane Risk of Bias 2 y Risk of Bias In Non-randomized Studies of Interventions . La certeza de la evidencia a través de la Grading of Recommendations Assessment, Development and Evaluation . Se realizó un metaanálisis con ayuda del programa estadístico R. Resultados: se incluyeron ocho estudios, con 1126 recién nacidos, y se identificaron seis técnicas de inserción: electrocardiograma intracavitario, electrocardiograma intracavitario asociado a ultrasonido, ultrasonido, fórmula, punto anatómico de referencia y punto anatómico de referencia modificado. Cinco técnicas redujeron significativamente el mal posicionamiento primario de la punta en comparación con el control (p<0,05). El electrocardiograma intracavitario redujo de manera significativa y más efectiva las arritmias, las complicaciones generales y la flebitis; la técnica que utilizó una fórmula también redujo las complicaciones generales. La infección, la infiltración, el mal posicionamiento secundario de la punta, la rotura del catéter, la trombosis, la oclusión y las lesiones de la piel asociadas con el catéter son eventos que no se revinieron significativamente. Conclusión: el electrocardiograma intracavitario y el uso de la fórmula fueron las técnicas más efectivas para reducir las complicaciones.
Objetivo: analisar a efetividade das técnicas de inserção de cateter central de inserção periférica na prevenção da ocorrência de complicações relacionadas a este dispositivo em recém-nascidos. Método: revisão sistemática da literatura e metanálise pareada e em rede, com busca realizada em sete bases de dados e na literatura cinzenta, inclusão de ensaios clínicos aleatorizados e não aleatorizados. O risco de viés foi avaliado pelas ferramentas da Cochrane Risk of Bias 2 e o Risk of Bias In Non-randomised Studies of Interventions. A certeza da evidência pelo Grading of Recommendations Assessment, Development and Evaluation. Realizou-se metanálise com auxílio do programa estatístico R. Resultados: oito estudos, com 1126 recém-nascidos, foram incluídos e seis técnicas de inserção identificadas: eletrocardiograma intracavitário, eletrocardiograma intracavitário associado à ultrassonografia, ultrassonografia, fórmula, marco de referência anatômico e marco de referência anatômico modificado. Cinco técnicas diminuíram significativamente o mau posicionamento primário da ponta quando comparadas com o controle ( p <0,05). O eletrocardiograma intracavitário diminuiu arritmias, complicações gerais e flebite de forma significativa e mais efetiva; a técnica que utilizou uma fórmula também reduziu complicações gerais. Infecção, infiltração, mau posicionamento secundário da ponta, ruptura do cateter, trombose, oclusão e lesão de pele associada ao cateter não foram eventos prevenidos significativamente. Conclusão: eletrocardiograma intracavitário e uso da fórmula foram as técnicas mais efetivas na redução de complicações.
Subject(s)
Humans , Infant, Newborn , Catheterization, Peripheral , Intensive Care Units, Neonatal , Treatment Failure , Neonatal Nursing , Central Venous CathetersABSTRACT
Introdução: O acesso venoso central é definido como a colocação de um cateter com sua extremidade posicionada na veia cava ou no átrio direito, tendo diversas funções no manejo do paciente em estado crítico. Pneumotórax causado durante a inserção do cateter é um incidente que resulta em dano ao paciente, sendo assim considerado um evento adverso relacionado à assistência médica. Objetivo: Analisar a ocorrência de pneumotórax como evento adverso relacionado à assistência à saúde após a inserção de um cateter venoso central. Método: Trata-se de um estudo quantitativo, transversal e analítico. Depois de realizar o cálculo amostral para obtenção da amostra, pacientes submetidos à inserção de cateter venoso central na instituição pesquisada no período de abril até setembro de 2022 foram incluídos na pesquisa, a coleta de dados utilizou dados secundários. Resultados: Uma amostra de 103 pacientes foi obtido, dos quais 10 (9,7%) dos pacientes apresentaram pneumotórax relacionado à inserção de cateter venoso central. de pneumotórax. A ocorrência de pneumotórax e o fato de o profissional que inseriu o cateter ser residente. A ocorrência de pneumotórax teve associação significativa (p 0,03) levando ao aumento do tempo de internação. Conclusão: O os resultados encontrados demonstram uma significativa ocorrência do evento adverso relacionado à assistência à saúde pneumotórax, após a inserção do Cateter Venoso Central (CVC). Estratégias voltadas para a segurança do paciente são fundamentais e devem ser perseguidas constantemente.
Introduction: Central venous access is defined as the placement of a catheter with its end positioned in the superior vena cava or in the right atrium, having several functions in the management of the patient in critical condition. Pneumothorax caused during catheter insertion is an incident that results in harm to the patient, thus considered an adverse event related to health care. Objective: To analyze the occurrence of pneumothorax as adverse events related to health care after insertion of a central venous catheter. Method: This is a quantitative, cross-sectional, analytical study. After performing the sample calculation to obtain the sample, patients who underwent insertion of a central venous catheter at the researched institution from April to September 2022 were included in the research, data collection used secondary data. Results: A sample of 103 patients was obtained, of which 10 (9.7%) of the patients had pneumothorax related to the insertion of a central venous catheter. of pneumothorax. The occurrence of pneumothorax and the fact that the professional who inserted the catheter was a resident. The occurrence of pneumothorax had a significant association (p 0.03) leading to increased length of stay. Conclusion: The results found demonstrate a significant occurrence of the adverse event related to pneumothorax health care, after the insertion of the Central Venous Catheter (CVC). Strategies aimed at patient safety are fundamental and must be pursued constantly.(AU)
Introducción: El acceso venoso central se define como la colocación de un catéter con su extremo posicionado en la vena cava superior o en la aurícula derecha, teniendo varias funciones en el manejo del paciente en estado crítico. El neumotórax causado durante la inserción del catéter es un incidente que resulta en daño para el paciente, por lo que se considera un evento adverso relacionado con la atención a la salud. Objetivo: Analizar la ocurrencia de neumotórax como eventos adversos relacionados con la atención a la salud después de la inserción de un catéter venoso central. Método: Se trata de un estudio cuantitativo, transversal, analítico. Después de realizar el cálculo de la muestra para la obtención de la muestra, se incluyeron en la investigación los pacientes que se sometieron a la inserción de un catéter venoso central en la institución investigada de abril a septiembre de 2022, la recolección de datos utilizó datos secundarios. Resultados: Se obtuvo una muestra de 103 pacientes, de los cuales 10 (9,7%) de los pacientes presentaron neumotórax relacionado con la inserción de un catéter venoso central. La ocurrencia de neumotórax y el hecho de que el profesional que insertó el catéter fuera residente. La ocurrencia de neumotórax tuvo una asociación significativa (p 0,03) que condujo a una mayor duración de la estancia. Conclusión: Los resultados encontrados demuestran una ocurrencia significativa del evento adverso relacionado con la atención de salud del neumotórax, después de la inserción del Catéter Venoso Central (CVC). Las estrategias dirigidas a la seguridad del paciente son fundamentales y deben ser seguidas constantemente.(AU)
Subject(s)
Pneumothorax , Nursing , Drug-Related Side Effects and Adverse Reactions , Central Venous CathetersABSTRACT
ABSTRACT Objective: to elaborate, based on the assessment of the nursing team's flushing practice, a care technology prototype aimed at promoting good practices in intravenous catheter maintenance in intensive care. Method: a technology elaboration study, developed in three stages: flushing practice assessment through a questionnaire completed by 108 nursing professionals working in intravenous catheter maintenance in intensive care settings of a public hospital located in the city of Rio de Janeiro, Brazil. Data collection took place from November 2019 to January 2020, with descriptive and inferential data analysis; analysis of this practice regarding the existence of errors according to the main guidelines and scientific evidence, with classification of types of errors in the light of the conceptual framework of patient safety; and technology prototype development. Results: 88% of participants perform flushing in their practice; 49.5% apply the continuous pressure technique on the syringe plunger; 22% perform flushing before, between and after medication administration; predominance of use of volume and syringes with gauges of 5 ml and 10 ml. Variables related to knowledge were associated with not performing flushing. There were active and latent errors that guided the technology prototype construction. Conclusion: a care guide was built that aims to increase nursing team's knowledge about good flushing practices and is configured as a barrier to error recurrence.
RESUMEN Objetivo: elaborar, a partir de la evaluación de la práctica de flushing del equipo de enfermería, un prototipo de tecnología asistencial con el objetivo de promover buenas prácticas en el mantenimiento de catéteres intravenosos en cuidados intensivos. Método: estudio de elaboración de tecnología, desarrollado en tres etapas: evaluación de la práctica de flushing a través de un cuestionario completado por 108 profesionales de enfermería que actúan en el mantenimiento de catéteres intravenosos en Unidades de Cuidados Intensivos de un hospital público ubicado en la ciudad de Río de Janeiro, Brasil. La recolección de datos ocurrió de noviembre de 2019 a enero de 2020, con análisis de datos descriptivo e inferencial; análisis de esta práctica en cuanto a la existencia de errores según las principales guías y evidencias científicas, con clasificación de tipos de errores a la luz del marco conceptual de seguridad del paciente; y desarrollo del prototipo tecnológico. Resultados: el 88% de los participantes realizan flushing en su consulta; el 49,5% aplica la técnica de presión continua sobre el émbolo de la jeringa; el 22% realiza flushing antes, entre y después de la administración de medicamentos; hubo predominio del uso de volumen y jeringas con calibres de 5 ml y 10 ml. Las variables relacionadas con el conocimiento se asociaron con no realizar el flushing. Existieron errores activos y latentes que orientaron la construcción del prototipo tecnológico. Conclusión: se elaboró una guía de atención que tiene como objetivo aumentar el conocimiento del equipo de enfermería sobre las buenas prácticas de flushing y se configura como una barrera para la recurrencia de errores.
RESUMO Objetivo: elaborar, com base na avaliação da prática do flushing da equipe de enfermagem, um protótipo de tecnologia de cuidado voltado a promover as boas práticas na manutenção dos cateteres intravenosos em terapia intensiva. Método: estudo de elaboração de tecnologia, desenvolvido em três etapas: avaliação da prática do flushing através de questionário preenchido por 108 profissionais de enfermagem atuantes na manutenção dos cateteres intravenosos em cenários de terapia intensiva de um hospital público localizado no município do Rio de Janeiro, Brasil. A coleta de dados ocorreu de novembro de 2019 a janeiro de 2020, com análise descritiva e inferencial dos dados; análise dessa prática quanto à existência de erros segundo as principais diretrizes e evidências científicas, com classificação dos tipos de erros à luz do referencial conceitual da segurança do paciente; e elaboração do protótipo da tecnologia. Resultados: 88% dos participantes realizam o flushing na sua prática; 49,5% aplicam a técnica de pressão contínua no êmbolo da seringa; 22% realizam o flushing antes, entre e após a administração de medicamentos; predomínio da utilização do volume e de seringas com calibres de 5 ml e 10 ml. Variáveis relacionadas ao conhecimento associaram-se à não realização do flushing. Houve erros ativos e latentes que orientaram a construção do protótipo da tecnologia. Conclusão: construiu-se um Guia de Cuidado que objetiva ampliar o conhecimento da equipe de enfermagem sobre as boas práticas do flushing e se configura como uma barreira à recorrência dos erros.
ABSTRACT
Objetivo: relatar casos de complicação e retenção de cateter central de inserção periférica em recém-nascidos. Método: Relato de caso sobre dois casos de enovelamento e retenção de cateter central de inserção periférica em uma Unidade de Terapia Intensiva Neonatal de um hospital no Sul do Brasil, entre maio e outubro de 2022. Resultados: No primeiro caso ocorreu dificuldade na remoção do cateter logo após sua inserção, com necessidade de remoção cirúrgica. No segundo identificou-se pela radiografia o enovelamento na fossa antecubital do membro superior neonatal, sem migração da ponta para região central, apesar de apresentar refluxo sanguíneo, sendo removido por tração manual. Conclusão: a formação de novelos ou nós em cateter central de inserção periférica e retenção tratam-se de complicações raras. Estar atento a este acontecimento possibilita a construção de evidências e estratégias de prevenção e manejo adequado na prática profissional.
Objetivo: reportar casos de complicación y retención de catéter central de inserción periférica en recién nacidos internados en la Unidad de Terapia Intensiva Neonatal. Método: estudio descriptivo, del tipo relato de caso, realizado entre mayo y octubre de 2022, en un hospital en el Sur de Brasil. Resultados: se han identificado dos casos de ennegrecimiento/formación de nudo y retención de catéter central de inserción periférica. En el primer caso ocurrió dificultad en la extracción del catéter inmediatamente después de su inserción, con necesidad de extracción quirúrgica. En el segundo caso, se identificó por la radiografía el ennegrecimiento en la fosa antecubital del miembro superior neonatal, sin migración de la punta hacia la región central, a pesar de presentar reflujo sanguíneo, siendo removido por tracción manual, sin resistencia e intercorgencias. Conclusión: la formación de ovillos o nudos en catéter central de inserción periférica y retención se tratan de complicaciones raras. Estar atento a este acontecimiento posibilita la construcción de evidencias y estrategias de prevención y manejo adecuado en la práctica profesional.
Objective: to report cases of complication and retention of central peripheral insertion catheter in newborns admitted to the Neonatal Intensive Care Unit. Method: descriptive case report study, conducted between May and October 2022, in a hospital in southern Brazil. Results: two cases of node folding/formation and retention of central peripheral insertion catheter were identified. In the first case, there was difficulty in removing the catheter soon after its insertion, requiring surgical removal. In the second case, the folding in the antecubital fossa of the neonatal upper limb was identified by radiography, without migration from the tip to the central region, despite presenting blood reflux, being removed by manual traction, without resistance or intercurrences. Conclusion: the formation of skeins or nodes in central catheter of peripheral insertion and retention are rare complications. Being aware of this event enables the construction of evidence and prevention strategies and proper management in professional practice.
Subject(s)
Humans , Male , Female , Infant , Infant, Newborn , Intensive Care Units, Neonatal , Central Venous Catheters/adverse effects , Child Health Services , InpatientsABSTRACT
Resumo Objetivo Sintetizar o conhecimento sobre o uso da lock terapia na prevenção e no tratamento da infecção da corrente sanguínea associada ao dispositivo de acesso vascular central de longa permanência em pacientes adultos e idosos hospitalizados. Métodos Revisão integrativa com busca nas bases de dados CINAHL, Cochrane Central, Embase, LILACS, PubMed, Scopus e Web of Science, no período de 1º janeiro de 2010 a 28 de setembro de 2021 sem restrições de idioma. Os dados foram analisados de forma descritiva. Resultados Foram identificados 16 estudos sendo seis (37,5%) sobre o uso da lock terapia como prevenção de infecção associada ao dispositivo de acesso vascular central e dez (62,5%) sobre tratamento. Os artigos sobre prevenção relataram o uso de soluções não antibióticas. Nove dos dez estudos que abordaram a lock terapia como tratamento, utilizaram soluções antibióticas. Dois estudos avaliaram a eficácia da lock terapia em curta duração (de três a quatro dias), sete em maior duração (entre 10 e 14 dias) e um não especificou a duração. Cada estudo descreveu uma técnica de intervenção e o tempo de permanência da solução intraluminal. Em relação ao risco de viés, foram avaliados como baixo risco: cinco ensaios clínicos randomizados, dois ensaios clínicos sem randomização e oito estudos observacionais. Apenas um estudo observacional foi classificado como risco moderado. Conclusão Na prevenção, identificou-se o uso de soluções não antibióticas como o etanol. Para o tratamento, foi utilizada a daptomicina endovenosa. Enquanto os estudos incluídos nessa revisão sobre prevenção não demonstraram evidência estatística, os dez estudos sobre tratamento demonstraram que a lock terapia é um complemento eficaz ao tratamento sistêmico, apresentando boas taxas de salvamento do cateter.
Resumen Objetivo Sintetizar el conocimiento sobre el uso de la terapia de bloqueo en la prevención y tratamiento de infecciones del torrente sanguíneo asociadas al dispositivo de acceso vascular central de larga permanencia en pacientes adultos y adultos mayores hospitalizados. Métodos Revisión integradora con búsqueda en las bases de datos CINAHL, Cochrane Central, Embase, LILACS, PubMed, Scopus y Web of Science, en el período del 1 de enero de 2010 al 28 de septiembre de 2021 sin restricción de idioma. Los datos fueron analizados de forma descriptiva. Resultados Se identificaron 16 estudios, de los cuales seis (37,5 %) trataban sobre el uso de la terapia de bloqueo como prevención de infecciones asociadas al dispositivo de acceso vascular central y diez (62,5 %) sobre tratamiento. En los artículos sobre prevención se relató el uso de soluciones no antibióticas. En nueve de los diez estudios que abordaban la terapia de bloqueo como tratamiento, se utilizaron soluciones antibióticas. En dos estudios se evaluó la eficacia de la terapia de bloqueo de corta duración (de tres a cuatro días), siete de mayor duración (entre 10 y 14 días) y uno sin especificar la duración. En cada estudio se describió una técnica de intervención y el tiempo de permanencia de la solución intraluminal. Con relación al riesgo de sesgo, fueron evaluados con riesgo bajo: cinco ensayos clínicos aleatorizados, dos ensayos clínicos no aleatorizados y ocho estudios observacionales. Solo un estudio observacional fue clasificado con riesgo moderado. Conclusión Para la prevención, se identificó el uso de soluciones no antibióticas como el etanol. Para el tratamiento, se utilizó la daptomicina intravenosa. Aunque los estudios incluidos en esta revisión sobre prevención no hayan demostrado evidencia estadística, los diez estudios sobre tratamiento demostraron que la terapia de bloqueo es un complemento eficaz para el tratamiento sistémico y presentó buenos índices de salvamento del catéter.
Abstract Objective To synthesize knowledge on the use of lock therapy for prevention and treatment of long-term central vascular access devices-associated bloodstream infection in hospitalized adult and elderly patients. Methods Integrative review conducted in CINAHL, Cochrane Central, Embase, LILACS, PubMed, Scopus, and Web of Science databases, from January 1st, 2010 to September 28th, 2021, without language restrictions. Data were analyzed descriptively. Results Sixteen studies were identified, six (37.5%) on the use of lock therapy for prevention of bloodstream infection associated with central vascular access devices, and ten (62.5%) on treatment. The articles on prevention reported the use of non-antibiotic solutions. Nine of the ten studies that addressed lock therapy as treatment used antibiotic solutions. Two studies assessed the effectiveness of lock therapy in a short duration (three to four days), seven in a longer duration (between 10 and 14 days), and one did not specify the length of time. Each study described an intervention technique and the length of stay of the intraluminal solution. Regarding the risk of bias, five randomized clinical trials, two non-randomized clinical trials, and eight observational studies were rated as low risk. Only one observational study was classified as moderate risk. Conclusion The use of non-antibiotic solutions such as ethanol was identified for prevention of bloodstream infection. For treatment, intravenous daptomycin was used. While the studies included in this review on prevention did not show statistical evidence, the ten studies on treatment demonstrated that lock therapy is an effective complement to systemic treatment, showing good catheter salvage rates.
ABSTRACT
Objetivo: construir um álbum seriado para enfermeiros sobre prevenção de infecção de cateter venoso central totalmente implantado (CVC-TI) em crianças onco-hematológicas. Método: estudo metodológico, realizado em duas etapas: revisão integrativa de literatura e produção do álbum seriado. Resultados: o álbum seriado contém fichas roteiros e ilustrações voltados para o profissional como forma de orientação e fácil acessibilidade, no momento do cuidado ao CVC-TI na criança onco-hematológica, apresentando 6 ilustrações, juntamente com a capa. Conclusão: acredita-se que o produto em questão se constitui como uma ferramenta importante que possibilita o aprendizado para os enfermeiros, contribuindo assim, para qualidade da assistência.
Objective: To build a flip chart for nurses about the prevention of subcutaneous port central venous catheter (SP-CVC) infections in children with blood cancer. Method: Methodological study carried out in two stages: integrative literature review and production of the flip chart. Results: The flip chart includes forms, scripts, and figures that aim to be an easily accessible tool to guide health workers in regard to providing SP-CVC related care to children with blood cancers, presenting a total of 6 images, including its cover. Conclusion: We believe that the product at hand is an important tool for the education of nurses, thus contributing to the quality of care.
Objetivo: elaborar un álbum seriado para enfermeros sobre la prevención de infección de catéter venoso central totalmente implantado (CVC-TI) en niños onco-hematológicos. Método: estudio metodológico, realizado en dos etapas: revisión bibliográfica integradora y elaboración del álbum seriado. Resultados: el álbum seriado contiene fichas, guiones y figuras ilustrativas dirigidas a los profesionales como forma de orientación y de fácil accesibilidad en el cuidado del CVC-TI en niños onco-hematológicos, presentando 6 ilustraciones junto con la portada. Conclusión: Se considera que el producto en cuestión es un instrumento importante que posibilita el aprendizaje de los enfermeros, contribuyendo así para la calidad de los cuidados.
Subject(s)
Humans , Pediatric Nursing , Educational Technology , Catheter-Related Infections , Evidence-Based Nursing , Central Venous CathetersABSTRACT
Introducción. Las bacteriemias relacionadas con catéteres venosos centrales (CVC) son frecuentes en pacientes pediátricos posquirúrgicos de cardiopatías congénitas complejas internados en la unidad de cuidados intensivos pediátricos cardiovascular (UCIP-CV) y tienen alta morbimortalidad. Objetivo. Analizar la efectividad de un programa interdisciplinario para prevención de bacteriemias relacionadas con CVC en la UCIP-CV. Material y métodos. Estudio de implementación, cuasiexperimental, antes-después, sin grupo control. Período de estudio del 1 de enero de 2008 al 31 de diciembre de 2018. Población: equipo de salud de la UCIP-CV que atiende pacientes posquirúrgicos de cardiopatías complejas de un hospital. Período preintervención del 1 de enero de 2008 al 31 de diciembre de 2008; período de intervención del 1 de enero de 2009 al 1 de enero de 2018. Intervención: implementación de un programa de mejora continua. Se analizaron tasas de bacteriemias CVC/1000 días y de uso de CVC/100 días, puntaje de RACHS, razón estandarizada de infecciones (REI), riesgo relativo (RR), intervalo de confianza del 95 % (IC95%), estimando una p < 0,05 como estadísticamente significativa. La tasa de referencia se estimó como el promedio del período 2008/2009 y se comparó la tasa anual con la tasa de referencia. Resultados. La tasa de referencia de bacteriemia 2008/2009 fue 10,6/1000 días CVC para analizar la REI. El puntaje de RACHS mayor a 3 fue similar en todos los períodos analizados. Se observó una reducción de la REI estadísticamente significativa (p < 0,05) en la comparación anual. Al comparar la tasa de bacteriemia/1000 días de CVC inicial de 11,9 vs. final de 3,8, se observó una reducción significativa (RR: 0,16; IC95%: 0,07-0,35; p < 0,001). Conclusiones. El programa fue efectivo; se observó reducción progresiva y significativa de la tasa de bacteriemias relacionadas con CVC en la UCIP-CV.
Introduction. Central venous catheter (CVC)related bacteremias are common in pediatric patients following surgery for complex congenital heart disease admitted to a pediatric cardiac intensive care unit (PCICU) and have a high morbidity and mortality. Objective.To analyze the effectiveness of an interdisciplinary program for the prevention of CVC-related bacteremias in the PCICU. Material and methods. Quasi-experimental,before and after implementation study without a control group. Study period: 01-01-2008 to 1231-2018. Population: PCICU staff who care for patients following surgery for complex heart disease at a hospital. Pre-intervention period: 0101-2008 to 12-31-2008; intervention period: 01-012009 to 01-01-2018. Intervention: implementation of an ongoing improvement program. The rate of CVC-related bacteremias/1000 days and CVC use/100 days, RACHS score, standardized infection ratio (SIR), relative risk (RR), and 95% confidence interval (CI) were analyzed and a p value < 0.05 was considered statistically significant. The reference rate was estimated as the average for the 2008-2009 period and the annual and reference rates were compared. Results. The bacteremia reference rate for 20082009 was 10.6/1000 days of CVC to analyze the SIR. A RACHS score over 3 was similar across all studied periods. The annual comparison showed a statistically significant reduction (p < 0.05) in the SIR. The comparison between the baseline bacteremia rate/1000 days of CVC (11.9) and the final rate (3.8) showed a significant reduction (RR: 0.16; 95 % CI: 0.070.35; p < 0.001). Conclusions. The program was effective; the rate of CVC-related bacteremias in the PCICU showed a progressive, significant reduction.
Subject(s)
Humans , Child , Respiratory Tract Diseases , Catheterization, Central Venous/adverse effects , Bacteremia/etiology , Bacteremia/prevention & control , Central Venous Catheters/adverse effects , Intensive Care Units, Pediatric , Intensive Care Units, Neonatal , Cause of Death , Bacteremia/epidemiologyABSTRACT
RESUMEN Objetivo : Describir las características y permanencia de los catéteres venosos centrales temporales (CVCT) para en hemodiálisis en el servicio de Nefrología de un hospital público en el periodo del 2015 al 2019. Métodos : Estudio analítico longitudinal de cohorte retrospectiva. Se incluyeron 2156 registros de procedimientos de colocación de CVCT para hemodiálisis en pacientes con enfermedad renal crónica estadio 5 (ERC-5), se registró la condición final de los catéteres durante el periodo de seguimiento. Se excluyeron los pacientes que se perdieron en el seguimiento. Resultados : Se evaluaron 2156 procedimientos en 1650 pacientes. La localización del catéter fue: Yugular 1019 (51,9 %), Subclavia 198 (9,2 %), Femoral 129(5,9%). Las principales causas de retiro fueron por: disfunción de catéter 730 (33,9 %) e infección 410 (19,1 %). En el curso de 5 años se observaron variaciones en la proporción pacientes que inician hemodiálisis con Fístulas Arteriovenosa (FAV) de 9,6 % a 17,1 % (p=0,042) y en la colocación de Catéteres Venoso Central (CVC) tunelizados al año de inicio de 8 % a 23,03 % (p<0.001). La mediana del tiempo de permanencia de un CVCT disminuyó de 81 días a 58 días. Los factores relacionados al retiro de CVCT disfuncional fueron: edad mayor de 60 años [HR: 5.31 (IC 95 %: 1,8 - 9,74), p<0.001] y etiología diabética [HR: 6,82 (IC95 %: 1,3 - 18,2), p=0,021]. Conclusión : El CVCT, es el acceso vascular más frecuente para inicio de hemodiálisis crónica, y tiene una prolongada permanencia. Los factores asociados al retiro de catéter disfuncional son la edad avanzada (> 60 años) y la etiología diabética. En el periodo de estudio las variaciones en la proporción de pacientes que inician terapia de hemodiálisis crónica con FAV son muy bajas.
ABSTRACT Objective : To describe the characteristics and permanence of temporary central venous catheters (CVCT) for hemodialysis in the Nephrology Service of a public Hospital in the period 2015-2019. Methods : Retrospective cohort longitudinal analytical study. 2156 records of CVCT placement procedures for hemodialysis in patients with stage 5 chronic kidney disease (CKD-5) were included, the final condition of the catheters was recorded during the follow-up period. Patients lost to follow-up were excluded. Results : Twenty-one hundred and fifty-six procedures were evaluated in 1,650 patients. Locations of catheters were Jugular, 1019 (51,9%); Subclavian, 198 (9,2%); and Femoral 129 (5,9%). Main causes of withdrawal were catheter dysfunction in 730 cases (33,9%) and infection in 410 (19,1%). During the five-year course, changes were observed, such as: variation in starting hemodialysis with AVF from 9.6% to 17,1% (p = 0,042), placement of tunneled CVCs during the first year of starting hemodialysis, from 8% to 23,0% (p 60 years), and diabetic etiology. During the study period, the variations in the proportion of patients who start chronic hemodialysis therapy with AVF are very low.
ABSTRACT
ABSTRACT Objectives: To describe the compliance to the practices of hand hygiene and hub disinfection before manipulation of the central venous catheter in two moments: before and after educational intervention. Adherence to hand hygiene was assessed with two methods: direct observation and video camera. Methods: Before and after study conducted with the nursing team in an adult intensive care unit, in São Paulo, Brazil, including 180 observations using video cameras and direct observation. Hand hygiene compliance before catheter manipulation and compliance with the correct technique and the hub disinfection for five seconds were observed. Results: When video cameras recording was observed, hand hygiene compliance increased from 46% to 66% and the use of the proper technique increased from 23% to 46% (p < 0.05). Regarding hub disinfection compliance, no difference was observed between the periods. Hand hygiene compliance in direct observation increased from 83% to 87% and in indirect observation, from 46% to 66% after the intervention. Conclusion: After the educational intervention, hand hygiene compliance before CVC manipulation and the use of the correct technique improved. When observed indirectly, the adherence to these practices was lower, reinforcing the Hawthorne effect.
RESUMO Objetivos: Descrever o cumprimento das práticas de higienização das mãos e desinfecção dos conectores antes da manipulação do cateter venoso central antes e após intervenção educativa. A adesão à higienização das mãos foi avaliada por observação direta e câmera de vídeo. Métodos: Estudo antes e depois realizado com a equipe de enfermagem em unidade de terapia intensiva para adultos, em São Paulo, Brasil, com 180 observações com câmeras de vídeo e observação direta. A adesão à higienização das mãos antes da manipulação do cateter e à técnica correta e desinfecção do conector por cinco segundos foram observadas. Resultados: Quando as câmeras de vídeo foram observadas, a adesão à higiene das mãos aumentou de 46% para 66% e o uso da técnica adequada aumentou de 23% para 46% (p < 0,05). Em relação à adesão à desinfecção do conector, não foi observada diferença entre os períodos. A adesão à higienização das mãos na observação direta aumentou de 83% para 87% e na indireta, de 46% para 66% após a intervenção. Conclusão Após a intervenção educativa, houve melhora na adesão à higienização das mãos antes da manipulação do cateter venoso central e no uso da técnica correta. Quando observada indiretamente, a adesão a essas práticas foi menor, reforçando o efeito Hawthorne.
RESUMEN Objetivo: Describir el cumplimiento de las prácticas de higiene de manos y desinfección del hub antes de la manipulación del catéter venoso central en dos momentos: antes y después de la intervención educativa. La adherencia a la higiene de manos se evaluó con dos métodos: observación directa y cámara de video. Métodos: Estudio antes-después realizado con el equipo de enfermería en una unidad de cuidados intensivos de adultos, en São Paulo, Brasil, que incluye 180 observaciones utilizando cámaras de video y observación directa. Se observaron el cumplimiento de la higiene de manos antes de la manipulación del catéter y el cumplimiento de la técnica correcta y la desinfección del hub durante cinco segundos. Resultados: Cuando se observó la grabación de cámaras de video, el cumplimiento de la higiene de manos aumentó del 46% al 66% y el uso de la técnica adecuada aumentó del 23% al 46% (p<0,05). En cuanto al cumplimiento de la desinfección de hubs, no se observó diferencia entre los períodos. El cumplimiento de la higiene de manos en observación directa aumentó del 83% al 87% y en observación indirecta del 46% al 66% tras la intervención. Conclusión: Después de la intervención educativa mejoró el cumplimiento de la higiene de manos antes de la manipulación del CVC y el uso de la técnica correcta. Cuando se observó indirectamente, la adherencia a estas prácticas fue menor, reforzando el efecto Hawthorne.
Subject(s)
Catheter-Related Infections , Central Venous Catheters , Evidence-Based Practice , Hand Hygiene , Nursing, TeamABSTRACT
ABSTRACT Objective: To check adherence to the Central Venous Catheter maintenance bundle in an Intensive Care Unit, after an educational intervention to the professionals who provide care to patients using this catheter. Method: Descriptive-exploratory study, carried out in two stages: stage 1 - educational intervention and stage 2 - verification/observation of adherence. Data were organized in the Microsoft Excel® and analyzed through the Stata®. Results: Sixty three workers participated in stage 1 and 44 in stage 2. The sample consisted of 64 observation opportunities. Among the domains observed, the recording of indication of permanence had an 8% compliance rate; aseptic technique in catheter handling, 3%; maintenance of the infusion system, 15%; and care with the central venous catheter dressing, 17%. The domains represent unwanted care according to the Positivity Index for assessing the quality of care. Conclusion: The findings show the need for discussions, training, and investments in constant strategies for the prevention of primary bloodstream infections related to the central venous catheter.
RESUMEN Objetivo: Averiguar la adhesión al bundle de manutención del Catéter Venoso Central en una unidad de terapia intensiva, tras intervención educativa a los profesionales que realizan el cuidado a los pacientes en uso de este catéter. Método: Estudio descriptivo exploratorio, realizado en dos etapas: Etapa 1 - intervención educativa y etapa 2 - averiguación/observación de la adhesión. Los datos fueron organizados en el Microsoft Excel® y analizados a través del Stata®. Resultados: Participaron de la etapa 1 63 profesionales y de la etapa 2, 44. La muestra fue constituida de 64 oportunidades de observaciones. Entre los dominios observados, el registro de indicación de permanencia presentó el 8% de tasa de conformidad, la técnica aséptica en el manejo del catéter, 3%, la manutención del sistema de infusión, 15% y los cuidados con el vendaje del catéter venoso central, 17%. Los dominios representan una asistencia no deseada de acuerdo con el Índice de Positividad de evaluación de la calidad de la asistencia. Conclusión: Los hallazgos demuestran la necesidad de debates, entrenamientos e inversiones en estrategias constantes para la prevención de infecciones primarias de corriente sanguínea relacionadas al catéter venoso central.
RESUMO Objetivo: Verificar a adesão ao bundle de manutenção do Cateter Venoso Central em uma Unidade de Terapia Intensiva, após intervenção educativa aos profissionais que realizam o cuidado aos pacientes em uso desse cateter. Method: Estudo descritivo-exploratório, realizado em duas fases, fase 1 - intervenção educativa, e fase 2 - verificação/observação da adesão. Os dados foram organizados no Microsoft Excel ® e analisados por meio do Stata®. Resultados: Participaram da fase 1 63 profissionais e da fase 2, 44. A amostra foi constituída de 64 oportunidades de observações. Entre os domínios observados, o registro de indicação de permanência apresentou 8% de taxa de conformidade; a técnica asséptica no manuseio do cateter, 3%; a manutenção do sistema de infusão, 15%; e os cuidados com o curativo do cateter venoso central, 17%. Os domínios representam uma assistência indesejada, conforme o Índice de Positividade de avaliação da qualidade da assistência. Conclusion: Os achados mostram a necessidade de discussões, treinamentos e investimentos em estratégias constantes para a prevenção de infecções primárias de corrente sanguínea relacionadas ao cateter venoso central.
Subject(s)
Central Venous Catheters , Intensive Care Units , Catheter-Related Infections , Patient Care BundlesABSTRACT
Abstract Objective: to evaluate usability of the Meu PICC (My PICC) app for follow-up of outpatients using peripherally inserted central catheters through the validated System Usability Scale instrument. Method: a cross-sectional study that applied the System Usability Scale to 30 patients using peripherally inserted central catheters, ten nurses and eight Information and Communication Technology professionals to assess usability of the app. Results: a statistical difference was observed between age and usability (p=0.006), as well as a negative correlation between app use time and usability (p=0.002). As per the System Usability Scale adjectival classification, 40.0% and 33.3% of the patients considered the app as the best possible to be imagined and as excellent, respectively. In relation to the nurses, 70.0% considered the app as the best possible to be imagined and 20.0% as excellent; of the Information and Communication Technology professionals, 50.0% considered the app as the best possible to be imagined and the other 50.0%, as excellent. Conclusion: the usability assessment showed that patients, nurses and ICT professionals considered the app useful for monitoring patients using PICCs and evaluated it as appropriate, evaluating it as the best possible to be imagined or as excellent. These results corroborate use of the Meu PICC app in the monitoring of outpatient use of PICCs.
Resumo Objetivo: avaliar a usabilidade do aplicativo Meu PICC para o acompanhamento extra-hospitalar de pacientes em uso de cateter central de inserção periférica por meio do instrumento validado System Usability Scale. Método: estudo transversal que aplicou o System Usability Scale a 30 pacientes em uso de cateter central de inserção periférica, dez enfermeiros e oito profissionais de tecnologia da informação para avaliar a usabilidade do aplicativo. Resultados: observou-se diferença estatística entre idade e usabilidade (p=0,006), bem como correlação negativa entre o tempo de utilização do aplicativo e usabilidade (p=0,002). Pela classificação adjetiva do System Usability Scale, 40,0% dos pacientes consideraram o aplicativo como o melhor imaginável e 33,3% como excelente. Com relação aos enfermeiros, 70,0% consideraram o aplicativo como o melhor imaginável e 20,0% como excelente; dos profissionais de tecnologia da informação, 50,0% consideraram o aplicativo como o melhor imaginável e 50,0% excelente. Conclusão: a avaliação de usabilidade mostrou que pacientes, enfermeiros e profissionais de TIC consideraram o aplicativo útil para o acompanhamento de pacientes em uso de PICC e o avaliaram como adequado, atribuindo-lhe a qualificação de melhor imaginável ou excelente. Estes resultados corroboram para o uso do aplicativo Meu PICC no acompanhamento de pacientes em uso extra-hospitalar de PICC.
Resumen Objetivo: evaluar la usabilidad de la aplicación Meu PICC para el seguimiento extrahospitalario de pacientes que usan catéter central de inserción periférica por medio del instrumento validado System Usability Scale. Método: estudio transversal que aplicó el System Usability Scale a 30 pacientes que usan catéter central de inserción periférica, diez enfermeros y ocho profesionales en tecnología de la información para evaluar la usabilidad de la aplicación. Resultados: hubo diferencia estadística entre la edad y la usabilidad (p=0,006), así como una correlación negativa entre el tiempo de uso de la aplicación y la usabilidad (p=0,002). Según la escala de clasificación de adjetivos del System Usability Scale, el 40,0% de los pacientes consideró que la aplicación era mejor imaginable y el 33,3% excelente. En cuanto a las enfermeras, el 70,0% consideró que la aplicación era mejor imaginable y el 20,0% excelente; de los profesionales en tecnologías de la información, el 50,0% consideró que la aplicación era mejor imaginable y el 50,0% excelente. Conclusión: la evaluación de usabilidad determinó que los pacientes, enfermeros y profesionales en TIC consideraron que la aplicación era útil para el seguimiento de pacientes que utilizan PICC y la calificaron como adecuada, otorgándole la calificación de mejor imaginable o excelente. Estos resultados confirman el uso de la aplicación Meu PICC en el seguimiento de pacientes que usan PICC fuera del hospital.
Subject(s)
Humans , Technology Assessment, Biomedical , Telemedicine , Information Technology , Telenursing , Central Venous CathetersABSTRACT
ABSTRACT Objective: to analyze the results of insertion procedures of Peripherally Inserted Central Catheters in newborns using two measurement methods. Methods: this is a randomized clinical trial, presenting descriptive and exploratory results of variables. It was held at a Neonatal Intensive Care Unit. Data were collected between September 2018 and 2019. The sample analyzed was 88 catheter insertion procedures, distributed in two groups. Study approved by an Institutional Review Board and obtained registration in the country and abroad. Descriptive analysis and logistic regression of data. Results: modified measurement obtained a significant difference for the central catheter tip location. Elective removals and adverse events were not significant between groups; however, poor positioning was related to adverse events. Conclusions: between the two methods analyzed, the modified measurement obtained better results in the proper catheter tip positioning and, consequently, less risk to patients.
RESUMEN Objetivo: analizar los resultados de los procedimientos de inserción del catéter central de inserción periférica en recién nacidos mediante dos métodos de medición. Métodos: ensayo clínico aleatorizado, presentando los resultados descriptivos y exploratorios de las variables. Realizado en la Unidad de Cuidados Intensivos Neonatales. Los datos fueron recolectados entre septiembre de 2018 y 2019. La muestra analizada fueron 88 procedimientos de inserción de catéter, divididos en dos grupos. Estudio aprobado por el Comité de Ética. Se obtuvo el registro en el país y en el exterior. Análisis descriptivo y regresión logística de los datos. Resultados: el método de medición modificado obtuvo una diferencia significativa para la ubicación central de la punta del catéter. Los retiros electivos y los eventos adversos no fueron significativos entre los grupos; sin embargo, la mala posición se relacionó con los eventos adversos. Conclusiones: entre los dos métodos analizados, la medida modificada obtuvo mejores resultados en el correcto posicionamiento de la punta del catéter y, en consecuencia, menor riesgo para los pacientes.
RESUMO Objetivo: analisar os resultados dos procedimentos de inserção de Cateter Central de Inserção Periférica em recém-nascidos utilizando dois métodos de mensuração. Métodos: ensaio clínico randomizado, apresentando os resultados descritivos e exploratórios das variáveis. Realizado em Unidade de Terapia Intensiva Neonatal. Dados foram coletados entre setembro de 2018 e 2019. A amostra analisada foi de 88 procedimentos de inserção do cateter, distribuídos em dois grupos. Estudo aprovado no Comitê de Ética. Obteve-se registro no país e exterior. Análise descritiva e regressão logística dos dados. Resultados: o método de medida modificada obteve diferença significativa para a localização central da ponta do cateter. Retiradas eletivas e eventos adversos não foram significativos entre os grupos, porém o mau posicionamento foi relacionado com os eventos adversos. Conclusões: entre os dois métodos analisados, a medida modificada obteve melhores resultados no posicionamento adequado da ponta do cateter e, consequentemente, menores riscos aos pacientes.
ABSTRACT
Resumen La fístula carótido yugular es una complicación inusual del proceder de colocación del catéter venoso central en la vena yugular interna. Esto puede tener serias consecuencias, tales como infecciones, embolismo y fallo cardíaco por sobrecarga de volumen, que requieren corrección. Reportamos el caso relativo a una paciente con fístula carótido yugular de 40 años de evolución secundaria a la realización de un cateterismo en la vena yugular interna durante la infancia, con evolución natural sin complicaciones relativas a la fístula post cateterismo.
Abstract Carotid-jugular fistula is one of the uncommon complications of jugular vein catheterization. It can have serious complications such as infection, embolization, and high output cardiac failure and requires invasive repair. We describe a case of uncommon carotid artery jugular vein artiovenous fistula following the insertion of a catheter for cardiac study during childhood, with 40 years of evolution without complications in relationship with post catheterism fistula.
Subject(s)
Humans , Female , Adult , Arteriovenous Fistula , Carotid Artery Injuries/complications , Central Venous Catheters , CubaABSTRACT
ABSTRACT Objective To analyze the occurrence of occlusions in peripherally inserted central venous catheters in pediatric patients in antineoplastic chemotherapy. Method Retrospective cohort, with 156 medical records of patients aged 0-19 years who underwent outpatient chemotherapy between 2013 and 2017 by this catheter, in a hospital in the city of Rio de Janeiro. Descriptive and inferential statistics were applied. Results 219 catheters were registered. Occlusion occurred in 141 (64.4%) catheters; 63 (44.7%) were removed because of occlusion, either alone or associated with another factor. Total occlusion alone led to the removal of 27 (12.3%) catheters. Occlusion was associated with: catheter dwell time, cyclophosphamide, neuroblastoma, bone metastasis and number of chemotherapy sessions. Conclusion Occlusion is an important complication because it occurred in more than half of the catheters and was one of the main reasons for withdrawal. The identified risk factors may guide the care to prevent this complication.
RESUMEN Objetivo Analizar la aparición de oclusiones en catéteres centrales de inserción periférica en niños y adolescentes sometidos a quimioterapia. Método Cohorte retrospectiva, con 156 registros de pacientes de 0 a 19 años que se sometieron a quimioterapia entre 2013 y 2017, en un hospital de Río de Janeiro. Se aplicaron estadísticas descriptivas e inferenciales. Resultados Se registraron 219 catéteres. La oclusión ocurrió en 141 (64.4%) catéteres; 63 (44.7%) se eliminaron por oclusión, ya sea solo o asociado con otro factor. La oclusión total sola condujo a la extracción de 27 (12.3%) catéteres. La oclusión se asoció con la duración de la estancia del catéter, ciclofosfamida, neuroblastoma, metástasis óseas y sesiones de quimioterapia. Conclusión La oclusión es una complicación importante, ocurrió en más de la mitad de los catéteres y fue una de las principales razones para la retirada. Los factores de riesgo pueden guiar la atención para prevenir esta complicación.
RESUMO Objetivo Analisar a ocorrência de oclusões em cateteres venosos centrais de inserção periférica nos pacientes infantojuvenis em quimioterapia antineoplásica. Método Coorte retrospectivo, com 156 prontuários de pacientes de 0 a 19 anos que realizaram quimioterapia ambulatorialmente entre 2013 e 2017 por este cateter, em hospital do município do Rio de Janeiro. Aplicou-se estatística descritiva e inferencial. Resultados Registraram-se 219 cateteres. A oclusão ocorreu em 141 (64,4%) cateteres; 63 (44,7%) foram retirados por causa da oclusão, seja isolada ou associada a outro fator. A oclusão total isoladamente foi motivo de retirada de 27 (12,3%) cateteres. A oclusão apresentou associação com: tempo de permanência do cateter, ciclofosfamida, neuroblastoma, metástase óssea e número de sessões de quimioterapia. Conclusão A oclusão é uma complicação importante, pois ocorreu em mais da metade dos cateteres e foi um dos principais motivos de retirada. Os fatores de risco identificados podem nortear o cuidado para prevenção desta complicação.
Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Young Adult , Central Venous Catheters/adverse effects , Neoplasms/drug therapy , Cohort Studies , Antineoplastic AgentsABSTRACT
Objective: to evaluate the effectiveness of the 50 IU/mL heparin solution compared to the 0.9% isotonic saline solution in preventing occlusion of the double lumen Hickman® catheter, 7 and 9 French, in patients undergoing hematopoietic stem cell transplantation. Method: a triple-blind randomized clinical trial. 17 double-lumen catheters (heparin group: n=7 and 0.9% isotonic saline group: n=10) were analyzed in which the two catheter routes were evaluated separately, totaling 34 lumens. The outcome variables were occlusion without reflux and complete occlusion. Descriptive analyses were performed using the Chi-square test and, of survival, according to the Kaplan-Meier test. Results: the mean number of days until the occlusion outcome was 52 in the heparin group and 13.46 in the 0.9% isotonic saline group in the white catheter route (p<0.001). In the red route, the mean follow-up days in the heparin group were 35.29, with no occlusion and 22.30 in the 0.9% isotonic saline group until the first occlusion (p=0.030). Conclusion: blocking with 50 IU/mL heparin solution is more effective than 0.9% isotonic saline in preventing occlusion of the Hickman® catheter. Brazilian Registry of Clinical Trials: RBR-3ht499.
Objetivo: avaliar a efetividade da solução de heparina 50 UI/mL comparada à solução salina isotônica 0,9% na prevenção de oclusão do Cateter de Hickman® duplo lúmen, 7 e 9 french, em pacientes submetidos ao transplante de células-tronco hematopoéticas. Método: ensaio clínico randomizado triplo cego. Foram analisados 17 cateteres duplo lúmen (grupo heparina n=7 e grupo solução salina isotônica 0,9% n=10) nos quais as duas vias do cateter foram avaliadas separadamente, totalizando 34 lúmens. As variáveis de desfecho foram oclusão sem refluxo e oclusão completa. As análises descritivas foram realizadas mediante o teste Qui-quadrado e, de sobrevida, sob o teste de Kaplan-Meier. Resultados: a média de dias até o desfecho oclusão foi de 52 no grupo heparina e de 13,46 no grupo solução salina isotônica 0,9% na via branca do cateter (p<0,001). Na via vermelha, a média de dias de acompanhamento do grupo heparina foi de 35,29, sem ocorrência de oclusão, e de 22,30 no grupo solução salina isotônica 0,9% até a primeira oclusão (p=0,030). Conclusão: o bloqueio com solução de heparina 50 UI/mL é mais efetivo em relação à solução salina isotônica 0,9% na prevenção da oclusão do Cateter de Hickman®. Registro Brasileiro de Ensaios Clínicos: RBR-3ht499.
Objetivo: evaluar la eficacia de la solución de heparina 50 UI/mL comparada con la solución salina isotónica al 0,9% para prevenir oclusiones en catéteres de Hickman® doble lumen, 7 y 9 French, en pacientes sometidos a trasplante de células madre hematopoyéticas. Método: ensayo clínico aleatorizado triple ciego. Se analizaron 17 catéteres de doble lumen (grupo de heparina: n=7 y grupo de solución salina isotónica al 0,9%: n=10) en los que se evaluaron por separado las dos vías del catéter, totalizando 34 lúmenes. Las variables de resultado fueron oclusión sin reflujo y oclusión completa. Los análisis descriptivos se realizaron mediante el test de Chi-cuadrado y, los de sobrevida, con el test de Kaplan-Meier. Resultados: la media de días hasta el resultado de oclusión fue de 52 en el grupo de heparina y de 13,46 en el grupo de la solución salina isotónica al 0,9% en la vía blanca del catéter (p<0,001). En la vía roja, la media de días de seguimiento del grupo de heparina fue de 35,29 sin oclusión y de 22,30 en el del grupo solución salina isotónica al 0,9% hasta la primera oclusión (p=0,030). Conclusión: el bloqueo con solución de heparina 50 UI/mL es más eficaz en relación con la solución salina isotónica al 0,9% para prevenir oclusiones en catéteres de Hickman®. Registro Brasileño de Ensayos Clínicos: RBR 3ht499.
Subject(s)
Effectiveness , Heparin , Sodium Chloride , Cecum , Randomized Controlled Trial , Aftercare , Disease Prevention , Kaplan-Meier Estimate , Evidence-Based Nursing , Catheters , Catheter Obstruction , Central Venous CathetersABSTRACT
ABSTRACT Objective: to evaluate the compliance of the nursing team's care practice in handling the central vascular catheter when changing dressings and equipment in an intensive care unit. Method: a descriptive, prospective, and observational research study. Data collection was conducted from January to March 2016 in an Intensive Care unit of a public hospital in Sergipe, northeastern Brazil. Direct observation of the professionals was conducted using a safe checklist. Descriptive statistics was used to determine the process indicators, and inferential statistics to determine the association between the variables, using the chi-square and Fisher's tests, with a 5% significance level. Results: 534 procedures corresponding to the exchange of equipment and dressings were observed, corresponding to 5,073 actions. As for the change of equipment, 2,136 actions were evaluated, most of them carried out by nursing technicians. Of the eight actions evaluated in each procedure, only two (25%) reached the desired compliance, with a positivity index between 90% and 99%. Regarding the dressing change, 2,937 actions were evaluated, all of which were performed by nurses. Of the eleven evaluated actions, eight (72%) achieved desired compliance, with a positivity index between 80% and 100%. Conclusion: the results analyzed are far from the desired compliances, demonstrating the need to implement strategies to ensure the safety culture during the care provided.
RESUMEN Objetivo: evaluar la conformidad de la práctica asistencial del equipo de Enfermería en la manipulación del catéter vascular central al momento de cambiar vendajes y equipos en una Unidad de Cuidados Intensivos. Método: investigación descriptiva, prospectiva y de observación. La recolección de datos tuvo lugar entre enero y marzo de 2016 en una Unidad de Cuidados Intensivos de un hospital público de Sergipe, noreste de Brasil. Se realizó una observación directa de los profesionales por medio de una checklist de verificación segura. Se utilizó análisis descriptivo para determinar los indicadores de proceso, y estadística inferencial para determinar la asociación entre las variables, usando las pruebas de chi-cuadrado y de Fisher, con un nivel de significancia del 5%. Resultados: se observaron 534 procedimientos correspondientes al cambio de equipos y vendajes, lo que correspondió a 5.073 acciones. En relación al cambio de equipos, se evaluaron 2.136 acciones, la mayoría realizadas por técnicos en Enfermería. De las ocho acciones evaluadas en cada procedimiento, solamente dos (25%) alcanzaron la conformidad deseada, con un índice de positividad del 90% al 99%. En relación con el cambio de vendajes, se evaluaron 2.937 acciones, todas ejecutadas por Enfermeros. De las once acciones evaluadas, ocho (72%) alcanzaron la conformidad deseada, con un índice de positividad del 80% al 100%. Conclusión: los resultados analizados distan de los niveles de conformidad deseados, lo que demuestra la necesidad de implementar estrategias para garantizar la cultura de la seguridad durante la atención provista.
RESUMO Objetivo: avaliar a conformidade da prática assistencial da equipe de enfermagem no manuseio do cateter vascular central na troca de curativos e de equipos em unidade de terapia intensiva. Método: pesquisa descritiva, prospectiva, observacional. A coleta de dados ocorreu de janeiro a março de 2016 em uma unidade de terapia intensiva de um hospital público do Sergipe, nordeste do Brasil. Realizada observação direta dos profissionais utilizando checklist de verificação segura. A análise descritiva foi utilizada para determinação dos indicadores de processo, e a estatística inferencial para determinar a associação entre as variáveis, usando os testes de Qui-Quadrado e Fisher, com nível de significância de 5%. Resultados: observados 534 procedimentos correspondentes a troca de equipos e curativos, correspondendo a 5073 ações. Quanto à troca de equipo 2.136 ações foram avaliadas, a maioria realizadas por técnicos em Enfermagem. Das oito ações avaliadas em cada procedimento, apenas duas (25%) alcançaram conformidade almejada, com índice de positividade entre 90% e 99%. Referente a troca de curativo, 2.937 ações foram avaliadas, sendo todas executadas por Enfermeiros. Das onze ações avaliadas, oito (72%) alcançaram conformidade desejada, com índice de positividade entre 80% e 100%. Conclusão: os resultados analisados estão distantes das conformidades almejadas, demonstrando a necessidade de implementação estratégias para garantir a cultura de segurança durante a assistência prestada.
Subject(s)
Humans , Patient Care Team , Catheter-Related Infections , Patient Safety , Central Venous CathetersABSTRACT
Introducción: La cateterización venosa central es un procedimiento usual en Unidades de Cuidados Intensivos (UCI). El ultrasonido (US) para guiar la cateterización, ofrece ventajas, permitiendo tener una imagen topográfica precisa del vaso, reduciendo las complicaciones, el tiempo y el número de punciones. Objetivo: determinar, si la US en la colocación de catéteres venosos centrales (CVC), podría disminuir el número de punciones y lograr la cateterización exitosa. Población y métodos: Estudio descriptivo, prospectivo de los CVC colocados mediante punción guiada por US, en una UCI polivalente del Hospital de Pediatría Juan P. Garrahan, entre el año 2018 al 2019. Población: pacientes de 1 mes a 18 años que requirieron colocación de un CVS por US. Se consideró significativo un valor de p< 0.05. Resultados: VYI en 66 pacientes (43,5%), VF fue en 86 pacientes (56,5%). 86 (56,5%) CVC, fueron insertados en el primer intento y 66 (43,5%), requirieron más de un intento. Las inserciones en VYI fueron exitosas en el primer intento en 46 pac. (53,5%) 20 pac. requirieron más de un intento (30,3%) p 0,004 OR 0,37 (IC 95% 0,18-0,78. En <6 meses los CVC colocados en VYI tuvieron menos riesgo de requerir más de un intento, con respecto a aquellos en los cuales se eligió la VF, p 0,0026 OR 0,31 (IC 95% 0,12 -0,75). 5,2% presentaron complicaciones, no hubo mortalidad relacionada al procedimiento. Conclusiones: La inserción de CVC guiados por US fue segura y significativamente exitosa en el primer intento cuando el vaso de elección fue la VYI, especialmente en < 6 meses (AU)
IIntroduction: Central venous catheterization is a common procedure in intensive care units (ICU). The use of ultrasound (US) to guide catheterization offers advantages, allowing for an accurate topographic image of the vessel, reducing complications as well as time and number of punctures. Objective: To determine whether the use of US for the placement of central venous catheters (CVCs) may decrease the number of punctures and achieve successful catheterization. Patients and methods: A descriptive, prospective study was conducted of CVCs placed by US-guided puncture at a general ICU of Hospital de Pediatría Juan P. Garrahan between 2018 and 2019. Patients from 1 month to 18 years of age who required US-guided placement of a CVC were included. A p< 0.05 was considered significant. Results: The internal jugular vein (IJV) was used in 66 (43.5%) and the femoral vein (FV) in 86 patients (56.5%). Overall, in 86 (56.5%) CVC were inserted on the first attempt and 66 (43.5%) required more than one attempt. Insertions into the VYI were successful on the first attempt in 46 (53.5%) patients and 20 (30.3%) patients required more than one attempt, p 0.004; OR 0.37 (95% CI 0.18-0.78). In patients <6 months CVCs placed in the IJV had a lower risk of requiring more than one attempt compared to those in which the FV was chosen, p 0.0026 OR 0.31 (95% CI 0.12 -0.75). Complications occurred in 5.2%; no procedure-related mortality was observed. Conclusions: US-guided insertion of CVC was safe and significantly successful on the first attempt when the vessel of choice was the IJV, especially in patients < 6 months (AU)
Subject(s)
Humans , Infant , Child, Preschool , Child , Adolescent , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Intensive Care Units, Pediatric , Ultrasonography, Interventional/instrumentation , Ultrasonography, Interventional/methods , Central Venous Catheters , Prospective Studies , Femoral Vein , Jugular VeinsABSTRACT
Resumen El empleo de catéter venoso central en la práctica clínica ha surgido como una opción de acceso vascular en pacientes con estancias hospitalarias prolongadas por diversas patologías del nuevo espectro epidemiológico. Se le llama así a un acceso al torrente sanguíneo a nivel central, para la administración de medicamentos entre otras funciones. Existen varios tipos de catéter venoso central, dependiendo de la necesidad del paciente así se elige el indicado. Sin embargo, las infecciones por el uso de dichos instrumentos invasivos, así como otras complicaciones no infecciosas, divididas en inmediatas como lo son la punción arterial, el sangrado, neumotórax o hemotórax, arritmia, embolismo aéreo o malposición del catéter y complicaciones tardías entre estas la estenosis venosa, trombosis venosa, la migración de catéter, la perforación miocárdica o el daño nervioso plantean un nuevo reto para la medicina actual. Este artículo describe las complicaciones, el manejo respectivo de cada una y estrategias para reducir la incidencia de las mismas.
Abstract The use of central venous catheter in clinical practice has emerged as a vascular access option in patients with prolonged hospital stays due to various pathologies of the new epidemiological spectrum. This is called an access to the bloodstream at the central level for the administration of medications and among other functions. There are several types of central venous catheters, depending on the patient's need so the one chosen is chosen. However, infections due to the use of such invasive instruments, as well as other non-infectious complications divided into immediate ones such as arterial puncture, bleeding, pneumothorax or hemothorax, arrhythmia, air embolism or catheter malposition and late complications between them venous stenosis, venous thrombosis, catheter migration, myocardial perforation or nerve damage pose a new challenge for current medicine. During this article it is presented as well as the complications, the respective management of each one is described and how to reduce their incidence.