Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Rev. bras. ortop ; 58(3): 523-531, May-June 2023. tab, graf
Article in English | LILACS | ID: biblio-1449816

ABSTRACT

Abstract Objective To evaluate the clinical and radiographic results and survival of the acetabular revision surgery of total hip arthroplasty with cemented implant without the use of reinforcement ring, associated with structural homologous bone grafting. Methods A total of 40 patients (44 hips) operated from 1995 to 2015 were retrospectively analyzed. Radiographs were evaluated according to the classification of the acetabular bone defect, graft shape, and the presence of osseointegration. Cases were considered as failures when the migration of the implant was > 5 mm in any direction, and/or the progression of radiolucency lines around the acetabular component were > 2 mm. We verified the association of radiographic findings with cases of failure using statistical tests and analyzed survival using the Kaplan-Meier curve. Results Of the 44 hips, 45.5% of the acetabular defects were Paprosky type 3A and 50% were 3B. In 65% of the hips, the graft configuration was classified as Prieto type 1 and in 31% as type 2. No radiographic evidence of osseointegration was observed in 13.6% of the cases. We observed 9 (20.5%) reconstruction failures. A correlation was observed between reconstruction failure and the absence of radiographic signs of graft osseointegration. Conclusion We observed good clinic and radiographic results, with survival of 79.54% in a mean follow-up of 9.65 years. Also, there was an association between absence of radiographic signs of osseointegration of the structural graft and failure in this series of patients with large bone defects. The failures did not correlate with the severity of the acetabular bone defect, thickness, or graft configuration.


Resumo Objetivo Avaliarosresultadosclínicos, radiográficos e a sobrevida da cirurgia de revisão acetabular de artroplastia total de quadril com implante cimentado sem uso de anel de reforço, associado à enxertia óssea homóloga estrutural. Métodos Um total de 40 pacientes (44 quadris) operados de 1995 a 2015 foram analisados retrospectivamente. As radiografias foram avaliadas de acordo com a classificação do defeito ósseo acetabular, o formato do enxerto e à presença de osteointegração. Foram considerados casos de insucesso a migração do implante > 5 mm em qualquer direção e/ou a progressão de linhas de radioluscência em torno do componente acetabular > 2mm. Verificamos a associação dos achados radiográficos com os casos de falha utilizando testes estatísticos e analisamos a sobrevida utilizando a curva de Kaplan-Meier. Resultados Dos 44 quadris, 45,5% dos defeitos acetabulares eram Paprosky tipo 3A e 50%, 3B. Em 65% dos quadris, a configuração do enxerto foi classificada como tipo 1 de Prieto e em 31% como tipo 2. Não foi observada evidência radiográfica de osteointe-gração em 13,6% dos casos. Observamos 9 (20,5%) falhas de reconstrução. Foi observada correlação entre falha da reconstrução com a ausência de sinais radiográficos de osteointegração do enxerto. Conclusão Observamos bons resultados clínicos e radiográficos, com sobrevida de 79,54% em seguimento médio de 9,65 anos. Também houve associação entre ausência de sinais radiográficos de osteointegração do enxerto estrutural e falha nesta série de pacientes com grandes defeitos ósseos. As falhas não se correlacionaram com a severidade do defeito ósseo acetabular, espessura ou configuraçãodoenxerto.


Subject(s)
Humans , Reoperation , Transplantation, Homologous , Cross-Sectional Studies , Osseointegration , Bone Transplantation , Arthroplasty, Replacement, Hip
2.
Rev. bras. ortop ; 57(5): 734-740, Sept.-Oct. 2022. tab, graf
Article in English | LILACS | ID: biblio-1407689

ABSTRACT

Abstract Objective The management of bone loss represents a challenge in revisions of total knee arthroplasty (rTKA) and in complex primary total knee arthroplasties (TKAs). The purpose of the present study was to evaluate the midterm outcomes (5-year minimum follow-up) of knee reconstructions with tantalum trabecular metal (TM) cones on bone defects Anderson Orthopaedics Research Institute (AORI) 2 and 3. Materials and MethodsA retrospective analysis of the medical records of patients operated on between July 2008 and November 2014 was performed, collecting the following data: age, gender, laterality, body mass index, etiology of arthrosis, comorbidities, AORI classification of bone defects, causes for revision, readmissions, reoperations, perioperative and postoperative complications, radiographic signs of osteointegration, and maintenance of the TM support. Results A total of 11 patients with a mean follow-up of 7.28 years (standard deviation [SD] = 1.88; range = 5.12-10 years) was evaluated, with 1 patient operated upon for a primary arthroplasty, 6 for revision arthroplasties, and 4 for a second revision arthroplasty (re-revision). There were complications with the surgical wound, injury to the extensor mechanism and loosening of the femoral component in three of the patients that led to the necessity of four procedures due to complications with the surgical wound, injury to the extensor mechanism and loosening of the femoral component. Radiological signs of osteointegration of the trabecular cones were observed in all patients. We did not observe migration of the TM cones or the prosthetic components in the sample. Conclusion The tantalum metaphyseal cones were able to provide efficient structural support to prosthetic implants with radiographic signs of osteointegration in the medium term.


Resumo Objetivo O manejo da perda óssea representa um grande desafio em cirurgias de revisão de artroplastia do joelho (rATJ) e em artroplastias totais do joelho (ATJ) primárias complexas. O objetivo do presente estudo foi avaliar os resultados em médio prazo (seguimento mínimo de 5 anos) das reconstruções de joelho nas quais cones de metal trabecular (MT) de tântalo foram utilizados para tratamento de defeitos ósseos tipos 2 e 3, de acordo com a classificação proposta pela Anderson Orthopaedic Research Institute (AORI). Métodos Feita análise retrospectiva dos prontuários dos pacientes operados entre julho de 2008 e novembro de 2014, coletando-se os seguintes dados: idade, gênero, lateralidade, índice de massa corporal, etiologia da artrose, comorbidade, classificação AORI da falha óssea, causa da revisão da artroplastia total do joelho, reinternações, reoperações, complicações peri- e pós-operatórias, ocorrência de osteointegração radiográfica e manutenção da função de suporte do MT. Resultados Foram avaliados 11 pacientes com tempo médio de seguimento de 7,28 anos (desvio padrão [DP] = 1,88; variação = 5,12-10 anos), sendo que 1 paciente foi submetido a artroplastia primária, 6 a artroplastia de revisão e 4 a segunda revisão de artroplastia (re-revisão). Três pacientes necessitaram de quatro reoperações devido a complicações com a ferida operatória, a lesão do mecanismo extensor e a soltura do componente femoral. Sinais de osteointegração dos cones trabeculados foram observados em todos os pacientes. Não observamos migração do cone de MT ou dos componentes protéticos. Conclusão Os cones metafisários de tântalo foram capazes de prover suporte estrutural eficiente aos implantes protéticos com sinais radiográficos de osteointegração em médio prazo.


Subject(s)
Humans , Postoperative Complications , Tantalum , Retrospective Studies , Osseointegration , Outcome Assessment, Health Care , Arthroplasty, Replacement, Knee , Knee Prosthesis
3.
Rev. bras. ortop ; 54(4): 477-482, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1042424

ABSTRACT

Abstract Objective To evaluate and compare the osteointegration of irradiated and nonirradiated frozen bone grafts used in 21 patients undergoing revision hip arthroplasty procedures with the Exeter technique. Methods A retrospective study of 21 patients undergoing revision hip arthroplasty with the Exeter technique using bone tissues treated or not with gamma radiation between 2013 and 2014. The patients were divided into two groups according to the use of grafts treated or not with ionizing radiation (gamma rays); as such, these groups were classified as irradiated or non-irradiated. The osteointegration results determined by radiographic analysis of these grafts were compared in the postoperative period of 6 and 12months. Results Comparing the graft osteointegration in all patients at 6 and 12months postoperatively, we noticed a significant difference in the radiographic evaluations in this period (p = 0.031). Out of the patients studied, 7 were from the irradiated group, and 14 belonged to the non-irradiated group. No statistically significant differences were observed (p = 0.804) regarding osteointegration when we compared the irradiated and non-irradiated groups. Conclusion There was no significant difference in the use of irradiated or nonirradiated grafts in revision hip arthroplasty procedures with the Exeter technique.


Resumo Objetivo Avaliar e comparar a osteointegração dos enxertos ósseos congelados irradiados e não irradiados utilizados em 21 pacientes submetidos a revisão de prótese do quadril pela técnica Exeter. Métodos Foi realizado estudo retrospectivo de 21 pacientes submetidos a revisão de artroplastia do quadril pela técnica Exeter comutilização de tecidos ósseos tratados ou não com radiação gama no período entre 2013 e 2014. Dividimos os pacientes em dois grupos, de acordo com o uso do enxerto tratado ou não com radiação ionizante (raios gama), que foram, portanto, classificados como: grupo irradiado e não irradiado. Os resultados da osteointegração por análise radiográfica destes enxertos foram comparados no pós-cirúrgico de 6 e 12 meses. Resultados Quando comparamos a osteointegração dos enxertos no pós-cirúrgico de 6 e 12 meses de todos os pacientes, notamos que houve diferença significativa entre as avaliações radiográficas neste período (p= 0,031). Dos pacientes estudados, 7 pertenciam ao grupo irradiado, e 14, ao grupo não irradiado. Não foram observadas diferenças estatisticamente significativas (p= 0,804) quando a osteointegração entre os grupos irradiados e não irradiados foi comparada. Conclusão Não houve diferença significativa no uso de enxerto irradiado e não irradiado nas revisões de artroplastias do quadril pela técnica Exeter.


Subject(s)
Humans , Male , Female , Arthroplasty , Tissue Banks , Osseointegration , Bone-Patellar Tendon-Bone Grafts
4.
Pesqui. vet. bras ; 37(12): 1491-1498, dez. 2017. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-895381

ABSTRACT

As afecções ortopédicas com perda de tecido ósseo são um desafio não só na medicina veterinária mas também na medicina humana. Analisou a interface entre compósito, constituído de esferas de quitosana e polimetilmetacrilato em falha óssea (leito receptor) de tíbia de coelhos, por meio de técnica radiológica, avaliação macroscópica e pela microscopia eletrônica de varredura, em diferentes tempos. Foram utilizados 12 coelhos adultos da raça Nova Zelândia, divididos em quatro Grupos Experimentais (E1, n=3; E2, n=3; E3, n=3 e E4, n=3), que tiveram as falhas ósseas das tibiais direitas preenchidas com compósito, e avaliadas no pós-operatório imediato, aos 30, 60 e 90 e 120 dias. Dos compósitos implantados nas tíbias de coelhos, apenas dois permaneceram em seus leitos receptores, enquanto que os demais se encontravam encapsulados no tecido subcutâneo. As esferas de quitosana, presentes nas superfícies dos biomateriais implantados, que mantiveram contato direto com o leito receptor de tíbias de coelhos apresentavam-se preservadas e não integraram ao tecido ósseo. Diante disso, para melhor compreensão do comportamento da quitosana como substituto ósseo, novas pesquisas serão necessárias.(AU)


Orthopedic diseases with bone loss are challenging in both veterinary and human medicine. The aim of this investigation was to analyze and compare the reactions at the interface between the composite, made of chitosan and polymethylmethacrylate, and the bone defect (receptor site) of the rabbits tibia through radiological and microscopic techniques and by scanning electron microscopy, in different periods. Twelve adult New Zealand rabbits were divided into four experimental groups (E1, n=3; E2, n=3; E3, n=3 and E4, n=3), which had the right tibial bone defects filled with the composite, and evaluated in the immediate postoperative, 30, 60, 90 and 120 days. Composite implanted in the tibia of rabbits, only two remained in their beds receivers, while the remaining were encapsulated in the subcutaneous tissue. Spheres of chitosan present in the biomaterial that has been deployed and were in direct contact with the bone defect, were preserved, however, were not integrated into the bone tissue. Therefore, to understand the behavior of chitosan as a bone substitute, further research is needed.(AU)


Subject(s)
Animals , Rabbits , Tibia/surgery , Tibial Fractures/veterinary , Composite Resins , Bone Substitutes/analysis , Polymethyl Methacrylate , Chitosan
5.
ROBRAC ; 26(79): 1-8, out./dez. 2017.
Article in Portuguese | LILACS | ID: biblio-905973

ABSTRACT

Diante da crescente expectativa quanto à estética em Odontologia e da necessidade de tratamentos metal free para casos específicos em regiões estéticas, o uso de implantes cerâmicos tem se tornado objeto de estudo e investimentos desde a década de 70, tornando-se hoje uma possível alternativa aos implantes de titânio. Assim, o objetivo deste estudo foi sistematizar o conhecimento disponível a respeito de implantes dentários de zircônia, avaliando sua viabilidade na implantodontia e a capacidade deste material em responder às exigências mecânicas e biológicas. Uma busca eletrônica foi realizada por meio do banco de dados PubMed utilizando a combinação das seguintes palavras- -chave: "zirconia", "dental implant", "zirconia implant" e "zirconia dental implant", sem restrição de idioma ou data de publicação. Esta pesquisa resultou em 801 trabalhos de potencial interesse. A seleção de artigos para inclusão no estudo com restrição de acordo com o objetivo proposto levou a seleção de 85 artigos relevantes para a revisão de literatura deste trabalho. De acordo com essa revisão, os resultados das pesquisas a respeito do uso da zircônia como matéria base na fabricação de implantes são promissores, embora a documentação científica disponível seja limitada pelas poucas e curtas experiências clínicas, principalmente em termos de longevidade. Estudos biológicos, mecânicos e clínicos publicados até a data parecem indicar que a zircônia pode ser uma excelente opção para os implantes de titânio, principalmente pelas suas propriedades mecânicas, aparência estética e menor adesão bacteriana.


Due to increasing demand for higher aesthetic in dentistry followed by the necessity of metal free rehabilitation for specific cases in esthetic regions, the use of ceramic implants has been object of study since the 70's, becoming today a possible alternative to titanium implants. The aim of this study was to systematize the knowledge available of zirconia implants, evaluating their viability and the ability of this material to respond to the mechanical and biological requirements. An electronic search was performed using the PubMed database and the combination of the following keywords: "zirconia", "dental implant", "zirconia implant" and "zirconia dental implant", without restriction of language or publication date. Eighty five articles were considered relevant to this study and the selection was fulfilled according to the proposed objective. According to this review, the results of research on the use of zirconia as the base material in implant manufacturing are promising, although available scientific documentation is limited by the few short clinical experiences, especially in terms of longevity. Biological, mechanical, and clinical studies published to date suggest that zirconia may be an excellent choice for titanium implants, mainly because of their mechanical properties, aesthetic appearance and lower bacterial adhesion.

6.
Rev. bras. ortop ; 50(2): 206-213, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-748341

ABSTRACT

OBJECTIVES: To evaluate the short-term performance of a type of implant manufactured in Brazil. METHODS: This study analyzed a cohort of 60 patients who underwent implantation of MD-4(r) acetabular components during primary hip arthroplasty procedures performed between January 1, 2010, and August 1, 2012. The patients were studied retrospectively with regard to clinical behavior, stability and radiological osseointegration. The patients were followed up for a minimum of 12 months and a maximum of 42 months (mean: 27) and were evaluated by means of the Harris Hip Score, SF-36 questionnaire and serial conventional radiographs. RESULTS: All the components were radiologically stable, without evidence of migration or progressive radiolucency lines. On average, the Harris Hip Score evolved from 36.1 to 92.1 (p < 0.001) and the SF-36 showed significant increases in all its domains (p < 0.001). No differences were observed among patients with osteoarthrosis, osteonecrosis, hip dysplasia or other conditions. CONCLUSIONS: The short-term results showed clinical and radiological signs of stability and osseointegration of the implants, which may represent a predictive factor regarding medium-term survival of this acetabular component. .


OBJETIVOS: avaliar o desempenho em curto prazo de um tipo de implante fabricado no Brasil. MÉTODOS: estudo de uma coorte de 60 pacientes que tiveram componentes acetabulares MD-4(r) implantados durante artroplastias primárias do quadril, entre 1 de janeiro de 2010 e 1 de agosto de 2012, e foram estudados retrospectivamente com relação ao comportamento clínico, à estabilidade e à osteointegração radiológica. Os indivíduos foram acompanhados por 12 meses no mínimo e no máximo 42 (média: 27) e avaliados por meio do Harris Hip Score, do questionário SF-36 e de radiografias convencionais seriadas. RESULTADOS: todos os componentes estavam radiologicamente estáveis, sem evidência de migração ou de linhas de radioluzência progressivas. Em média, o Harris Hip Score evoluiu de 36,1 para 92,1 (p < 0,001) e o SF-36 mostrou incremento significativo em todos os domínios (p < 0,001). Nenhuma diferença foi observada entre pacientes com osteoartrose, osteonecrose, displasia do quadril ou outras condições. CONCLUSÕES: os resultados de curto prazo mostraram sinais clínicos e radiológicos de estabilidade e de osteointegração dos implantes, o que pode representar um fator preditivo quanto à sobrevivência em médio prazo do componente acetabular considerado. .


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Arthroplasty, Replacement, Hip , Osseointegration , Titanium
7.
Rev. bras. ortop ; 49(3): 260-266, May-June/2014. tab, graf
Article in English | LILACS | ID: lil-712773

ABSTRACT

OBJECTIVE: To evaluate the results from proximal fixation of uncemented conical femoral components in patients with a type C proximal femur and compare them with the results obtained from type A and B femurs. METHODS: This was a retrospective study on 87 patients with 90 uncemented total hip arthroplasty procedures. Three patients (three hips) were excluded because their follow-up lasted for less than two years. The follow-up ranged from 2 to 4.3 years and the mean was 2.8 years. The Bicontact femoral implant model was used. The preoperative radiographs were evaluated, the femurs were classified as Dorr types A, B or C and the cortical indices were measured. The patients were evaluated clinically by means of the Harris Hip Score (HHS), before the surgery and at the last follow-up. The sequences of postoperative radiographs were compared regarding stability, complications and any signs of osseointegration of the femoral prosthesis. RESULTS: Among the 87 hips with follow-up greater than two years, 32 femurs were type A (37%), 37 type B (42%) and 18 type C (21%). Before the operation, the mean HHS was 39.4 for types A and B and 38.8 for type C. At the last follow-up, the mean HHS was 89.8 for types A and B and 86 for type C. None of the 87 femoral components had been revised by the time of the last follow-up; all of them were considered stable. In 86 cases, the radiographs showed signs of osseointegration. CONCLUSION: There were no significant differences in the clinical results or in the fixation (and osseointegration) of conical uncemented femoral prostheses with proximal porosity, among femurs with different types of femoral morphology according to the Dorr classification. This conclusion may vary if another implant model were to be used...


OBJETIVO: avaliar os resultados de componentes femorais cônicos não cimentados de fixação proximal em pacientes com fêmur proximal tipo C e compará-los com os resultados obtidos em fêmures tipos A e B. MÉTODOS: estudo retrospectivo de 87 pacientes com 90 ATQs não cimentadas. Três pacientes (três ATQs) foram excluídos por seguimento menor do que dois anos. Houve seguimento de dois a 4,3 anos e média de 2,8 anos. Foram usados implantes femorais modelo Bicontact. As radiografias pré-operatórias foram avaliadas e classificados os fêmures nos tipos A, B ou C de Dorr, além da aferição dos índices corticais (IC). Clinicamente os pacientes foram avaliados por meio do Harris Hip Score (HHS), antes da cirurgia e no último seguimento. Compararam-se as radiografias pós-operatórias sequenciais quanto a estabilidade, complicações e sinais de osteointegração ou não da prótese femoral. RESULTADOS: dos 87 quadris com seguimento maior do que dois anos, 32 fêmures eram tipo A (37%), 37 tipo B (42%) e 18 tipo C (21%). No pré-operatório a média do HHS foi de 39,4 nos tipos A e B e 38,8 no tipo C. No último seguimento o HHS em média foi de 89,8 nos tipos A e B e 86 no tipo C. Nenhum dos 87 componentes femorais foi revisado até o último seguimento. Todos foram considerados estáveis. As radiografias de 86 demonstraram sinais de osteointegração. CONCLUSÃO: não houve diferença significativa nos resultados clínicos e na fixação (e osteointegração) de próteses femorais não cimentadas cônicas, com porosidade proximal, em fêmures dos diferentes tipos de morfologia femoral de acordo com a classificação de Dorr. Essa conclusão pode variar em caso de uso de outro modelo de implante...


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Arthroplasty, Replacement, Hip , Evaluation of Results of Therapeutic Interventions , Femur , Osseointegration , Prostheses and Implants
8.
Rev. bras. ortop ; 49(3): 245-251, May-June/2014. graf
Article in English | LILACS | ID: lil-712774

ABSTRACT

OBJECTIVES: the aim of this study was to evaluate the surgical technique and determine the initial results, with a minimum follow-up of two years, from total knee arthroplasty revisions in which trabecular metal cones made of tantalum were used at the Knee Surgery Center of the National Institute of Traumatology and Orthopedics (INTO) or at the authors' private clinic between July 2008 and December 2010. METHODS: ten patients were included in the study prospectively, through clinical and radiographic evaluations. RESULTS: seven patients presented evolution without complications relating to the tantalum cones used. Five of these patients said that they did not have any pain and all of them were able to walk without needing crutches. In all the cases, we observed that osseointegration of the tantalum cones had occurred. No migration or loosening of the implants was observed, nor was osteolysis. CONCLUSION: use of trabecular metal cones made of tantalum for treating AORI type II or II bone defects was capable of providing efficient structural support to the prosthetic revision implants, in evaluations with a short follow-up...


OBJETIVOS: avaliar a técnica cirúrgica e determinar os resultados iniciais, com seguimento mínimo de dois anos, das revisões de artroplastia total do joelho nas quais cones de metal trabecular tântalo foram empregados pelo Centro de Cirurgia do Joelho do Instituto Nacional de Traumatologia e Ortopedia (Into) ou na clínica privada dos autores de julho de 2008 a dezembro 2010. MÉTODOS: foram incluídos no estudo 10 pacientes, prospectivamente em avaliação clínica e radiográfica. RESULTADOS: sete pacientes apresentaram evolução sem complicações relacionadas ao uso de cones de tântalo, cinco negam dor e todos deambulam sem necessidade de muletas. Em todos os casos, verificamos osteointegração dos cones de tântalo e não foi observada migração ou soltura de implantes, assim como osteólise. CONCLUSÃO: o uso de cones de metal trabecular tântalo para tratamento de defeitos ósseos tipo II ou III Aori apresenta-se capaz de prover suporte estrutural eficiente aos implantes protéticos de revisão em avaliação de curto seguimento...


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Osseointegration , Prostheses and Implants , Surgical Instruments
9.
Pesqui. vet. bras ; 33(6): 765-770, June 2013. ilus
Article in Portuguese | LILACS | ID: lil-680793

ABSTRACT

Os traumas que resultam em fraturas ósseas, principalmente as cominutivas, têm uma importância muito grande na rotina clínico-cirúrgica veterinária e humana. Foi realizada falha segmentar de 6mm na região metafisária medial da tíbia esquerda de 12 coelhos, a qual foi preenchida com implante constituído de matriz óssea mineralizada heteróloga fragmentada e metilmetacrilato, preservados em glicerina (98%) para a sua reconstrução. Foi realizada avaliação morfológica e radiológica aos 30, 60, 90 e 120 dias e observou-se a incorporação do implante ao leito receptor, em 100% dos casos, mostrando ser biologicamente compatível, pois promoveu a reparação das falhas ósseas, sem sinais de infecção, migração e/ou rejeição, sendo uma opção de substituto para preencher defeitos ósseos.


The traumas that result in bone fractures, especially comminuted, have high importance in veterinary and human surgical routine. A 6mm of segmental defect was performed at the medial metaphyseal region of the left tibia of 12 rabbits and an association of fragmented heterologue mineralized bone matrix and methylmethacrylate conserved in glycerin (98%) was used as a graft to fill the bone defect. To evaluate the procedure morphological and radiological exams were performed after 30, 60, 90 and 120 days. There was gradual integration of the bone graft in the receptor bed in 100% of the cases showing that the material is biologically compatible as it promotes bone defect reparation without signs of infection, migration and/or rejection and can be considered one more option to be used as a substitute to fill bone defects.


Subject(s)
Animals , Bone Matrix/injuries , Bone Matrix , Osseointegration , Orthopedics/veterinary , Rabbits , Radiography , Radiography/veterinary , Glycerol/chemistry , Methylmethacrylate/analysis
10.
Full dent. sci ; 4(13): 44-51, out.-dez. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-681672

ABSTRACT

Os tratamentos através do uso da osseointegração possuem indicação e contraindicações específicas. Em alguns casos, as alterações ao redor dos alvéolos advindas de extrações dentárias modificam significativamente a espessura e a altura do rebordo, especialmente quando a perda do dente é decorrente de um trauma dentário, envolvimento periodontal ou a parede vestibular do rebordo é perdida durante a extração. Esses tipos de deficiências ósseas no rebordo podem dificultar ou impossibilitar o uso de certas técnicas de implantes dentários devido ao insuficiente volume ósseo para abrigar implantes de dimensões adequadas. A utilização de uma técnica incorreta pode acarretar um resultado protético inadequado, tanto pela forma estética quanto pela funcionalidade. Este estudo tem por objetivo revisar a literatura científica relacionada à técnica de expansão cirúrgica de rebordo alveolar, também conhecida como “Split Crest”, e demonstrar um caso clínico


Treatments through the use of osseointegration have specific indications and contraindications. In some cases, the changes around the alveoli arising from dental extractions significantly alter the thickness and height of the ridge, especially when tooth loss is a result of dental trauma, or periodontal involvement of the buccal wall edge is lost during extraction. These types of deficiencies in the bony ridge may hamper or prevent the use of certain techniques for dental implants due to insufficient bone volume to harbor implants of adequate dimensions. Using the wrong technique can lead to inadequate prosthetic result both in form and aesthetics for functionality. This study aims to review the scientific literature related to the technique of surgical expansion of the alveolar ridge, also known as “Split Crest, and demonstrate a case report


Subject(s)
Humans , Male , Adult , Surgery, Oral/methods , Dental Implants , Osseointegration , Osteotomy/methods , Tomography
11.
Rev. dor ; 12(2)abr.-jun. 2011.
Article in Portuguese | LILACS | ID: lil-590989

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Alterações de sensibilidade trigeminal podem levar à dor neuropática após manipulação cirúrgica. Essas queixas geram dúvidas. Primeiro:são reais? Pois, nem sempre há relação causal entre implante-nervo. Segundo: o implante deve ser removido? O objetivo deste estudo foi rever a literatura sobre o assunto.CONTEÚDO: A literatura é farta em informações sobre perdas de implantes relacionadas à osteointegração, mas são raros os estudos sobre perdas relacionadas à lesão de nervo ou à dor neuropática. O risco para longevidade de implantes é multifatorial. Contribuem: saúde do paciente,técnica cirúrgica, região receptora e ativação funcional,entre outros fatores. Dor é complicação com significativas implicações clínicas, psicológicas, sociais e legais; exigindo atenção especial aos pacientes, muitas vezes prolongada ou permanente. Atualmente a literatura especializada já é volumosa sobre prevalência de anormalidades sensitivas e lesão de nervo após procedimentos odontológicos. Em conjunto, essas informações sugerem conduta que inclua exame minucioso, interconsultas e adoção de medidas preventivas, curativas ou paliativas para o tratamentoda dor. A remoção do implante depende dessa análise,portanto, nem sempre é uma decisão simples.CONCLUSÃO: Informações sobre remoção de implantes dentais devido à dor ou lesão de nervo são escassas nem sempre homogêneas, porém já alertam de que essa decisão nem sempre é simples. Ela depende da adoção de medidas diagnósticas, algumas especializadas, incluindoos exames de imagem. Diagnóstico e tratamento precoceda lesão de nervo e da dor neuropática são benéficos ao paciente e têm importantes implicações éticas e legais.


BACKGROUND AND OBJECTIVES: Trigeminal sensitivity changes may lead to neuropathic pain after surgical handling. These complaints generate questions.First: are they real? Because a causal relationship between implant and nerve is not always present. Second: shouldthe implant be removed? This study aimed at reviewing the literature on the subject.CONTENTS: The literature is prodigal on information about loss of implants related to osteointegration, butthere are few studies on losses related to nerve loss or to neuropathic pain. The risk for implants longevity is multifactorial.Contributors are: patients' health, surgical technique, receptor region and functional activation, amongo ther factors. Pain is a complication with significant clinical,psychological, social and legal implications, requiring special attention to patients, very often prolonged or permanent. Currently, specialized literature is already voluminous about the prevalence of sensory abnormalities and nervous injury after dental procedures. Together,these pieces of information suggest an approach including detailed exams, inter consultations and the adoption of preventive, curative or palliative measures to treat pain. Implant removal depends on this analysis and it is not always a simple decision. CONCLUSION: Information about dental implants removal due to pain or nervous injury is scarce and notalways homogeneous, however it already calls the attention to the fact that such decision is not always simple. It depends on the adoption of diagnostic measures, some of them specialized, including image exams. Early diagnosis and treatment of nervous injury and neuropathic pain are beneficial to patients and have major ethic and legal implications.


Subject(s)
Dental Implantation , Facial Pain , Pain, Postoperative
SELECTION OF CITATIONS
SEARCH DETAIL