Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery ; (12): 832-836, 2023.
Artículo en Chino | WPRIM | ID: wpr-1011053

RESUMEN

Objective:To investigate the application value of near-infrared autofluorescence imaging in identifying and protecting parathyroid glands in endoscopic thyroid surgery. Methods:From May 2022 to February 2023, 158 patients who underwent endoscopic thyroid surgery in the Department of Thyroid and Breast Vascular Surgery of Guilin People's Hospital were selected. The endoscopic fluorescence camera system was used to monitor the parathyroid glands under autofluorescence during endoscopic thyroid surgery. A total of 214 pieces were collected, among which the first 15 cases that could not be preserved in situ during the operation needed to be autotransplanted or the tissue clamped parts that could not be clearly identified as parathyroid glands were sent to fast-frozen pathology to determine whether they were parathyroid glands. Results:Among the first 15 patients who could not be preserved in situ during the operation or whose anatomy could not be clearly defined, 23 parathyroid glands were detected by autofluorescence imaging, 21 parathyroid glands were confirmed by pathology, and 2 were adipose tissue, with an accuracy rate of 91.30%; 158 patients underwent surgery Blood calcium decreased 2 hours after operation compared with preoperative blood calcium(P<0.05), decreased blood calcium 5 days after operation compared with preoperative blood calcium(P<0.01), and increased slightly 5 days after the operation compared to blood calcium 2 hours after the operation, but the difference was not statistically significant(P>0.05); while comparing parathyroid hormone(PTH), PTH at 2 hours after operation decreased significantly compared with PTH before operation(P<0.01), and PTH at 5 days after operation compared with PTH before operation PTH also decreased(P<0.01), but increased compared with PTH 2 hours after operation(P=0.001). Conclusion:In laparoscopic thyroid surgery, the application of near-infrared autofluorescence imaging technology can help surgeons quickly identify and protect parathyroid glands, and reduce the incidence of permanent hypoparathyroidism. Combining autofluorescence imaging, visual anatomy recognition under magnification of laparoscope, and intraoperative frozen pathological examination "trinity" method can improve the success rate of parathyroid gland recognition.


Asunto(s)
Humanos , Glándulas Paratiroides/trasplante , Glándula Tiroides/cirugía , Calcio , Hormona Paratiroidea , Imagen Óptica/métodos , Laparoscopía , Tiroidectomía/métodos
2.
Neuroscience Bulletin ; (6): 1840-1858, 2023.
Artículo en Inglés | WPRIM | ID: wpr-1010665

RESUMEN

The mammalian brain is a highly complex network that consists of millions to billions of densely-interconnected neurons. Precise dissection of neural circuits at the mesoscopic level can provide important structural information for understanding the brain. Optical approaches can achieve submicron lateral resolution and achieve "optical sectioning" by a variety of means, which has the natural advantage of allowing the observation of neural circuits at the mesoscopic level. Automated whole-brain optical imaging methods based on tissue clearing or histological sectioning surpass the limitation of optical imaging depth in biological tissues and can provide delicate structural information in a large volume of tissues. Combined with various fluorescent labeling techniques, whole-brain optical imaging methods have shown great potential in the brain-wide quantitative profiling of cells, circuits, and blood vessels. In this review, we summarize the principles and implementations of various whole-brain optical imaging methods and provide some concepts regarding their future development.


Asunto(s)
Animales , Encéfalo/fisiología , Mapeo Encefálico/métodos , Neuronas/fisiología , Imagen Óptica/métodos , Mamíferos
3.
Chinese Journal of Oncology ; (12): 450-454, 2022.
Artículo en Chino | WPRIM | ID: wpr-935236

RESUMEN

Objective: Local recurrence is the main cause of treatment failure in patients with oral squamous cell carcinoma (OSCC). This study was proposed to investigate the feasibility of near infrared fluorescence (NIF) via indocyanine green (ICG) for monitoring surgical marginal in operation for OSCC patients. Methods: In 35 patients with OSCC treated surgically in the Department of Oral and Maxillofacial Surgery, Nanjing University School of Medicine, from January 2019 to June 2020, ICG (0.75 mg/kg) was administered intravenously via elbow vein at (12±1) hours before surgery, and NIF was performed intraoperatively on the surgical field and the cut edge of the surgically excised specimen, and fluorescence intensity was measured for OSCC tissue and normal oral mucosa, abnormal fluorescence signals were taken and subjected to rapid cryopathological examination. Correlation between NIF tumor boundary grading and pathological tumor boundary grading was analyzed by Spearman correlation analysis. Results: Clear ICG NIF was obtained for tumor lesions in all 35 patients, with a positive rate of 100%. The fluorescence intensity of OSCC tissue was (412.73±146.56) au, which was higher than that of normal oral mucosa tissue [(279.38±82.56) au, P<0.01]. Abnormal fluorescence signals were detected at the tumor bed and the cut edge of the surgical resection specimen in 4 patients, of which 2 cases were pathologically confirmed as cancer cell residue and 2 cases as inflammatory cell infiltration. The rate of positive detection of cut margins using ICG NIF technique in OSCC was 5.7% (2/35). Twenty of the 35 OSCC patients had grade 1, 11 of grade 2, and 4 of grade 3 tumor borders revealed by NIF of surgical resection specimens, which was positively correlated with pathological tumor border (r=0.809, P<0.001). Conclusions: ICG NIF technique can effectively detect the residual cancer cells at the incision margin, which is of great clinical value in reducing local recurrence of OSCC after surgery due to intraoperative cancer residue.


Asunto(s)
Humanos , Carcinoma de Células Escamosas/cirugía , Neoplasias de Cabeza y Cuello , Verde de Indocianina , Márgenes de Escisión , Neoplasias de la Boca/cirugía , Neoplasia Residual , Imagen Óptica/métodos , Carcinoma de Células Escamosas de Cabeza y Cuello/cirugía
4.
Int. j. morphol ; 39(5): 1278-1282, oct. 2021. ilus
Artículo en Inglés | LILACS | ID: biblio-1385505

RESUMEN

SUMMARY: Progesterone receptors are expressed in the reproductive organs of adult sheep, where they regulate morphofunctional and reproductive development. However, various studies have shown the presence of these receptors in the uterus of prepubertal females. It is not clear what role these receptors have at this level of development in uterine tissue. Therefore, it is relevant as a first step in the investigation, to determine the expression and histological distribution of the progesterone receptor in prepubertal sheep in order to determine possible functions at this level of reproductive development. Immunohistochemical analysis allows visualizing the specific presence of a protein in the cellular and histological context, however, the results displayed through digital images are qualitative data and subject to the observer's criteria. In this work, a quantitative analysis method of immunohistochemical expression of the progesterone receptor in ovine endometrium is presented, using digital analysis of images, by means of integrated optical density of digital photographs of histological sections processed with immunohistochemical methods. The results show the possibility of quantitatively evaluating the expression of progesterone receptors in the endometrial stroma and prepubertal endometrial glands by applying the integrated optical density analysis of digital images.


RESUMEN: Los receptores de progesterona se expresan en los órganos reproductores de ovejas adultas, donde regulan el desarrollo morfofuncional y reproductivo. Sin embargo, diversos estudios han demostrado la presencia de estos receptores en útero de hembras prepúberes. No está claro, el papel que estos receptores tienen en este nivel de desarrollo en tejido uterino. Por lo que, es relevante como primer paso en la investigación, determinar la expresión y distribución histológica del receptor de progesterona en ovejas prepúberes con el fin determinar posibles funciones en este nivel de desarrollo reproductivo. El análisis inmuno- histoquímico permite visualizar la presencia específica de una proteína en el contexto celular e histológico, sin embargo, los resultados visualizados a través de imágenes digitales, son datos cualitativos y sujeto al criterio del observador. En este trabajo se presenta un método de análisis cuantitativo de expresión inmunohistoquímica del receptor de progesterona en endometrio ovino, utilizando análisis digital de imágenes, mediante densidad óptica integrada de fotografías digitales de cortes histológicos procesados con métodos inmunohistoquímicos. Los resultados muestran la posibilidad de evaluar cuantitativamente la expresión de los receptores de progesterona en el estroma endometrial y las glándulas endometriales prepúberes aplicando el análisis de densidad óptica integrado de imágenes digitales.


Asunto(s)
Animales , Ovinos , Receptores de Progesterona/metabolismo , Endometrio/metabolismo , Inmunohistoquímica , Densitometría , Imagen Óptica/métodos
5.
Arq. bras. oftalmol ; 82(5): 412-416, Sept.-Oct. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1019424

RESUMEN

ABSTRACT Purpose: To evaluate the usefulness of fundus autofluorescence imaging of diabetic patients without retinopathy to investigate early retinal damage. Methods: Fundus autofluorescence images of patients with type 2 diabetes mellitus without retinopathy (diabetic group) and age-sex matched healthy patients (control group) were recorded with a CX-1 digital mydriatic retinal camera after detailed ophthalmologic examinations. MATLAB 2013a software was used to measure the average pixel intensity and average curve width of the macula and fovea. Results: Fifty-six eyes of 28 patients, as the diabetic group, and 54 eyes of 27 healthy patients, as the control group, were included in this study. The mean aggregation index was 168.32 ± 37.18 grayscale units (gsu) in the diabetic group and 152.27 ± 30.39 gsu in the control group (p=0.014). The mean average pixel intensity value of the fovea was 150.87 ± 35.83 gsu the in diabetic group and as 141.51 ± 31.10 gsu in the control group (p=0.060). The average curve width value was statistically higher in the diabetic group than in the control group (71.7 ± 9.2 vs. 59.4 ± 8.6 gsu, respectively, p=0.03). Conclusion: Fundus autofluorescence imaging analysis revealed that diabetic patients without retinopathy have significant fluorescence alterations. Therefore, a noninvasive imaging technique, such as fundus autofluorescence, may be valuable for evaluation of the retina of diabetic patients without retinopathy.


RESUMO Objetivo: Avaliar a utilidade da autofluorescência do fundo de olho de pacientes diabéticos sem retinopatia para investigar lesões precoces na retina. Métodos: Imagens de autofluorescência do fundo de olho de pacientes com diabetes mellitus do tipo 2 sem retinopatia (grupo diabético) e indivíduos saudáveis pareados por idade e sexo (grupo controle) foram registrados com uma câmera retiniana digital midriática CX-1 após exames oftalmológicos detalhados. O software MATLAB 2013a foi usado para medir a intensidade média do pixel e a largura média da curva da mácula e fóvea. Resultados: Cinquenta e seis olhos de 28 pacientes, como o grupo diabético, e 54 olhos de 27 indivíduos saudáveis, como grupo controle, foram incluídos neste estudo. O índice médio de agregação foi de 168,32 ± 37,18 unidades de escala de cinza (gsu) no grupo diabético e em 152,27 ± 30,39 gsu no grupo controle (p = 0,014). O valor médio da intensidade de pixel na fóvea foi de 150,87 ± 35,83 gsu no grupo diabético e de 141,51 ± 31,10 gsu no grupo controle (p=0,060). O valor médio da largura da curva foi estatisticamente maior no grupo diabético do que no grupo controle (71,7 ± 9,2 vs. 59,4 ± 8,6 gsu, respectivamente; p = 0,03). Conclusão: A análise por imagens de autofluorescência de fundo de olho revelou que pacientes diabéticos sem retinopatia apresentam alterações significativas de fluorescência. Portanto, uma técnica de imagem não invasiva, como a autofluorescência de fundo de olho, pode ser valiosa para a avaliação da retina de pacientes diabéticos sem retinopatia.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Enfermedades de la Retina/diagnóstico por imagen , Diabetes Mellitus Tipo 2/fisiopatología , Retinopatía Diabética/diagnóstico , Imagen Óptica/métodos , Fondo de Ojo , Enfermedades de la Retina/fisiopatología , Angiografía con Fluoresceína/métodos , Agudeza Visual , Estudios de Casos y Controles
6.
Gac. méd. Méx ; 155(5): 458-462, Sep.-Oct. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1286543

RESUMEN

Introduction: Patients with diabetic macular edema can develop fundus autofluorescence alterations; thus far, these alterations have been more widely studied with scanning or confocal laser systems. Objective: To describe and classify fundus autofluorescence abnormal patterns in patients with diabetic macular edema using the fundus autofluorescence system with a flash camera. Method: Observational, retrospective, cross-sectional, descriptive study. Fundus autofluorescence digital images of non-comparative cases with untreated diabetic macular edema, obtained and stored with a flash camera system, were assessed. Inter-observer variability was evaluated. Results: 37 eyes of 20 patients were included. Lens opacity was the most common cause of inadequate image quality. Five different fundus autofluorescence patterns were observed: decreased (13%), normal (40%), single-spot hyper-autofluorescent (17 %), multiple-spot hyper-autofluorescent (22 %) and plaque-like hyper-autofluorescent (8 %). The kappa coefficient was 0.906 (p = 0.000). Conclusions: Different fundus autofluorescence phenotypic patterns are observed with flash camera systems in patients with diabetic macular edema. A more accurate phenotypic classification could help establish prognostic factors for visual loss or for the design of clinical trials for diabetic macular edema.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Edema Macular/diagnóstico por imagen , Retinopatía Diabética/diagnóstico por imagen , Imagen Óptica/instrumentación , Imagen Óptica/métodos , Fenotipo , Variaciones Dependientes del Observador , Edema Macular/clasificación , Edema Macular/etiología , Estudios Transversales , Estudios Retrospectivos , Diabetes Mellitus Tipo 2/complicaciones , Retinopatía Diabética/clasificación , Retinopatía Diabética/complicaciones , México
7.
Rev. bras. oftalmol ; 78(4): 260-263, July-Aug. 2019. graf
Artículo en Portugués | LILACS | ID: biblio-1013684

RESUMEN

Resumo A distrofia macular anular concêntrica benigna (DMACB) é uma patologia retiniana rara e provavelmente subdiagnosticada em nosso meio, que se caracteriza por um defeito retiniano em bull's eye sem uso prévio de antimaláricos, associado à preservação relativa da acuidade visual. Devido à escassez de publicações sobre o tema, existem poucos dados referentes aos resultados dos exames complementares nesta patologia. No presente artigo, apresenta-se a descrição da autofluorescência em um caso clássico de DMACB, ainda inédita na literatura, podendo acrescentar achados importantes para auxiliar no diagnóstico e seguimento da doença.


Abstract The benign concentric annular macular dystrophy (BCAMD) is a very rare and probably underdiagnosed eye disease, characterized by a retinal fault in bull's eye pattern, without the association with antimalarial use, but related with good visual acuity. Since there aren't many publications about this condition, is hard to find data regarding the results of complementary examination. In this article, is presented the description of fundus autofluorescence in a classic BCAMD case, yet unpublished, and capable of helping the diagnosis and follow-up of this pathology.


Asunto(s)
Humanos , Masculino , Anciano , Retina/fisiopatología , Angiografía con Fluoresceína/métodos , Hipopigmentación/diagnóstico , Degeneración Macular/diagnóstico , Oftalmoscopía/métodos , Atrofia , Tomografía de Coherencia Óptica , Epitelio Pigmentado de la Retina/patología , Imagen Óptica/métodos , Fondo de Ojo , Lipofuscina/metabolismo
8.
Rev. Assoc. Med. Bras. (1992) ; 65(3): 330-332, Mar. 2019. graf
Artículo en Inglés | LILACS | ID: biblio-1003036

RESUMEN

SUMMARY Vitiligo is the most common depigmenting, chronic acquired disease of the skin and mucosa. However, vitiligo of an unclassified type and mucosal subtype affecting only one area of the mucosa is considered quite uncommon. The diagnosis of vitiligo, regardless of its type, is clinical. Nonetheless, a device that allows the visualization of the tissue fluorescence may be useful for confirming the diagnosis. We present the use of wide-field optical fluorescence device for complementary examination and diagnosis of unusual cases of mucosal vitiligo located only in angles of the mouth.


RESUMO O vitiligo é a doença crônica adquirida despigmentante mais comum da pele e/ou da mucosa. Entretanto, o vitiligo do tipo não classificado e subtipo de mucosa afetando apenas uma área da mucosa é considerado bastante incomum. O diagnóstico de vitiligo, independentemente do seu tipo, é clínico. No entanto, o uso de um dispositivo que permite a visualização da fluorescência tecidual pode ser útil para a confirmação do diagnóstico de vitiligo. Apresentamos o uso do dispositivo de exame complementar de fluorescência óptica de campo amplo para o diagnóstico de um caso incomum de vitiligo de mucosa localizado apenas em ângulos da boca.


Asunto(s)
Humanos , Masculino , Vitíligo/diagnóstico por imagen , Imagen Óptica/métodos , Enfermedades de la Boca/diagnóstico por imagen , Mucosa Bucal/diagnóstico por imagen , Vitíligo/patología , Imagen Óptica/instrumentación , Fluorescencia , Persona de Mediana Edad , Enfermedades de la Boca/patología , Mucosa Bucal/patología
10.
Braz. oral res. (Online) ; 33: e0088, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1019596

RESUMEN

Abstract The main of the study was quantify the effect of two ceramics with two underlying resin cements on apparent fluorescence levels. Buccal surfaces of two bovine incisors were ground flat producing one enamel and one dentin substrate. The veneers were fabricated (0.5 and 1.0 mm thickness) using two ceramics (IPSe.max Press and IPSe.max Zirpress, Ivoclar Vivadent). Veneers were cemented using either light-cured (Variolink II, Ivoclar Vivadent) or self-adhesive dual (Rely X U200, 3M ESPE) cement. The layered Control group materials had no cement application. Semi-quantitative fluorescence image analysis (Matlabs software, Matworks) involved processing the images as captured under each daylight (DL, Gretagmacbeth) and ultraviolet illuminants (UVA, Sylvania) within a neutral-gray lightbox (Macbeth Spectral Light). Statistical analysis of the quantitative fluorescence values was performed using two-way ANOVA and Tukey's test (p < 0.05). The e.max Zirpress on the dentin substrate produced greater fluorescence (p < 0.05) when subjected to UV illumination and more fluorescence (p < 0.05) than e.max Press in both cement groups. Light-cured cement produced higher (p < 0.05) fluorescence than the dual-cement with e.max Press on enamel under UV illumination. The fluorescence for e.max Press on the dentin substrate was greater (p < 0.05) than for e.max Zirpress using dual self-adhesive cement subjected to daylight illumination. Thus, it is possible to conclude that the combination of ceramic and cement produce definite, significant effects on the apparent fluorescence, vital quality for restorative dentistry.


Asunto(s)
Animales , Bovinos , Cementos de Resina/química , Valores de Referencia , Propiedades de Superficie , Ensayo de Materiales , Cerámica/química , Reproducibilidad de los Resultados , Esmalte Dental/efectos de los fármacos , Esmalte Dental/química , Coronas con Frente Estético , Dentina , Dentina/efectos de los fármacos , Imagen Óptica/métodos , Luz
11.
Journal of Gynecologic Oncology ; : e27-2016.
Artículo en Inglés | WPRIM | ID: wpr-213434

RESUMEN

OBJECTIVE: Indocyanine green with near-infrared fluorescence imaging (NIR-ICG) is a new tracer modality in the limelight used for lymphatic mapping. The advantage of this method is to provide real-time image during surgery. To use ICG for image guided lymph node dissection, a surgeon needs to know initial appearing time and duration. METHODS: A 52-year-old woman undertook surgery diagnosed with endometrial cancer. She had no past medical history and her body mass index was 25.3 kg/m2. Preoperative magnetic resonance imaging examination revealed 2.7 cm sized cancerous mass in the endometrial cavity with superficial myometrial invasion without lymph node enlargement. Four mL (1.25 mg/mL) of ICG solution was prepared for injection. For each site, 1 mL of solution was injected superficially, 2-3 mm into the cervical submucosa and another 1 mL was injected deep, 1-2 cm into the stroma of the cervix. We recorded video with 30° 10 mm scope equipped with a specific lens and light source emitting both visible and NIR light (KARL STORZ GmbH & Co. KG, Tuttlingen, Germany). RESULTS: Pelvic lymph node was visualized from around 5 minutes. ICG was dispersed into organs after hysterectomy (53 minutes after ICG injection), yet we could clearly identify sentinel lymph node (SLN). Pathology revealed endometriod adenocarcinoma grade I, myometrial invasion with less than half of myometrium and no lymph node metastasis. CONCLUSION: Cervical injection of ICG provides good visualization of SLN from 5 minutes to over an hour. Our film gives an idea about time management to make a plan for surgery and not to miss SNLs.


Asunto(s)
Femenino , Humanos , Persona de Mediana Edad , Adenocarcinoma/diagnóstico por imagen , Colorantes/uso terapéutico , Neoplasias Endometriales/diagnóstico por imagen , Verde de Indocianina/uso terapéutico , Metástasis Linfática/diagnóstico por imagen , Imagen Óptica/métodos , Ganglio Linfático Centinela/diagnóstico por imagen , Imagen de Lapso de Tiempo/métodos
12.
Dental press j. orthod. (Impr.) ; 20(3): 58-63, May-Jun/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-751406

RESUMEN

OBJECTIVE: The present study assessed the maxillary dental arch changes produced by surgically assisted rapid maxillary expansion (SARME). METHODS: Dental casts from 18 patients (mean age of 23.3 years) were obtained at treatment onset (T1), three months after SARME (T2) and 6 months after expansion (T3). The casts were scanned in a 3D scanner (D-250, 3Shape, Copenhagen, Denmark). Maxillary dental arch width, dental crown tipping and height were measured and assessed by ANOVA and Tukey's test. RESULTS: Increased transversal widths from T1 and T2 and the maintenance of these values from T2 and T3 were observed. Buccal teeth tipping also showed statistically significant differences, with an increase in all teeth from T1 to T2 and a decrease from T2 to T3. No statistically significant difference was found for dental crown height, except for left first and second molars, although clinically irrelevant. CONCLUSION: SARME proved to be an effective and stable procedure, with minimum periodontal hazards. .


OBJETIVOS: o presente estudo teve o objetivo de avaliar as alterações dentárias e periodontais decorrentes da Expansão Rápida da Maxila Assistida Cirurgicamente (ERMAC). MÉTODOS: foram obtidos os modelos de gesso de 18 pacientes (média de idade de 23,3 anos), ao início (T1), 3 meses após a ERMAC (T2) e 6 meses após a expansão (T3). Os modelos foram digitalizados (Scanner 3D 3Shape D-250) e mensuraram-se as distâncias transversais, bem como a inclinação e a altura da coroa clínica dos dentes posteriores. Para análise dos resultados, aplicou-se a análise de Variância e o teste de Tukey. RESULTADOS: nas distâncias transversais, observou-se um aumento de T1 para T2 e uma manutenção de T2 para T3. As inclinações dentárias demonstraram diferenças estatisticamente significativas em alguns dentes; porém, numericamente tenderam a um aumento de T1 para T2 e a uma diminuição de T2 para T3. Não se observou diferença estatisticamente significativa na altura da coroa clínica, exceto nos primeiros e segundos molares do lado esquerdo, porém, clinicamente irrelevante. CONCLUSÕES: a ERMAC demonstrou ser um procedimento efetivo e estável, com mínima repercussão periodontal. .


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Adulto Joven , Diente/anatomía & histología , Periodoncio/anatomía & histología , Técnica de Expansión Palatina/instrumentación , Osteotomía Le Fort/métodos , Arco Dental/cirugía , Maxilar/cirugía , Diente Premolar/anatomía & histología , Estudios Retrospectivos , Estudios de Seguimiento , Corona del Diente/anatomía & histología , Diente Canino/anatomía & histología , Imagenología Tridimensional/métodos , Modelos Dentales , Imagen Óptica/métodos , Diente Molar/anatomía & histología
13.
Arq. bras. oftalmol ; 77(3): 139-142, May-Jun/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-723836

RESUMEN

Purpose: To describe the findings of fundus autofluorescence (FAF) imaging in patients with blunt ocular trauma. Methods: In this non-interventional retrospective study, we reviewed medical records and imaging examination results. The data analyzed included gender, age, laterality, trauma etiology, time between trauma and imaging, visual acuity, changes in the retinal periphery, fundus examination results, and FAF imaging findings. FAF imaging was performed using a Topcon TRC-50DX Retinal Camera (Tokyo, Japan). Results: Eight eyes from 8 patients were studied. The mean age was 27.6 years (range, 19-43 years). Men (n=7) were more frequently affected by blunt ocular trauma than women (n=1). Physical aggression was the most common trauma etiology (n=3), followed by accidents with fireworks (n=2). Other causes were car accidents (n=1), occupational trauma caused by a grinder (n=1), or being hit by a stone (n=1). Visual acuity ranged from 20/80 to light perception. Traumatic pigment epitheliopathy (TPE) was identified in 5 cases, choroidal rupture in 3 cases, subretinal hemorrhage in 3 cases, and Purtscher's retinopathy in 1 case. Hypoautofluorescence was observed in cases of choroidal rupture, recent subretinal hemorrhage, and intraretinal hemorrhage, and in two cases of TPE. Hyperautofluorescence was observed in cases of old subretinal hemorrhage and at the edge of the lesion in two cases of choroidal rupture. Mild hyperautofluorescence was observed in the posterior pole in Purtscher's retinopathy. Three cases of TPE exhibited hypoautofluorescence with diffuse hyperautofluorescent areas. Conclusion: FAF imaging is a non-invasive method for assessing changes in the posterior segment of the eye resulting from blunt ocular trauma. Furthermore, this technique provides valuable information. We described the findings of FAF imaging in cases of TPE, choroidal rupture, subretinal hemorrhage, and Purtscher's retinopathy. .


Objetivo: Descrever os achados do exame de autofluorescência do fundo de olho (AFF) em pacientes vítimas de trauma ocular contuso. Métodos: Estudo retrospectivo, não intervencionista, realizado através da revisão de prontuários e exames de imagem. Os dados analisados foram: sexo, idade, lateralidade, etiologia do trauma, tempo decorrente entre o trauma e a realização do exame, acuidade visual, alterações na periferia da retina, diagnóstico fundoscópico e achados ao exame de AFF (realizada no aparelho Topcon TRC-50DX Retinal Camera). Resultados: Oito olhos de 8 pacientes foram estudados. A idade média foi de 27,6 anos (de 19 a 43 anos), o sexo masculino (n=7) foi mais acometido do que o feminino (n=1), agressão física foi a etiologia mais comum do trauma (n=3), seguido de acidente com fogos de artifício (n=2). Outras causas foram acidente automobilístico (n=1), trauma ocupacional com lixadeira (n=1) e pedrada (n=1). A acuidade visual variou de 20/80 a percepção luminosa. Epiteliopatia pigmentar traumática (EPT ) foi identificada em 5 casos, rotura de coroide em 3, hemorragia subretiniana em 3 e retinopatia de Purtscher em 1 caso. Hipoautofluorescência foi observada nos casos de rotura de coroide, hemorragia subretiniana recente, hemorragia intrarretiniana e em 2 casos de EPT. Hiperautofluorescência foi visualizada nos casos de hemorragia subretiniana em degradação, na borda de 2 casos de roturas de coroide e discretamente no polo posterior na retinopatia de Purtcher. Três casos de EPT apresentaram hipoautofluorescência com pontos hiperautofluorescentes difusos. Conclusão: O exame de AFF permite avaliar as alterações do segmento posterior do olho decorrentes do trauma ocular contuso de forma não invasiva, somando informações valiosas. Foram descritos achados do exame ...


Asunto(s)
Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Lesiones Oculares/diagnóstico , Imagen Óptica/métodos , Heridas no Penetrantes/diagnóstico , Coroides/lesiones , Lesiones Oculares/etiología , Lesiones Oculares/fisiopatología , Angiografía con Fluoresceína/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Retina/lesiones , Agudeza Visual/fisiología , Heridas no Penetrantes/etiología , Heridas no Penetrantes/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA