Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. J. Pharm. Sci. (Online) ; 53(4): e17293, 2017. tab, graf, ilus
Artigo em Inglês | LILACS | ID: biblio-889435

RESUMO

ABSTRACT A novel, accurate, precise and economical stability indicating Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) method, was developed and validated for the quantitative determination of ubidecarenone (UDC) in bulk drug, UDC marketed formulation and UDC loaded cubosomes (CBMs) nanocarriers through Response surface methodology (RSM) design with three factors and three levels was performed to optimize the chromatographic variables followed by forced degradation studies of UDC were performed to detect degradation peak. RP-HPLC separation was achieved using mobile phase consisting of Acetonitrile:Tetrahydrofuran:Deionised water in the ratio 55:42:3 and a flow rate of 1.0 mL/min was optimized with a standard retention time (Rt) of 2.15 min, through experiment. The method was found linear in the concentration range of 5-100 µg/mL with a regression coefficient of 0.999. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 3.04 µg/mL and 9.11 µg/mL, respectively.


Assuntos
Ubiquinona/análise , Cromatografia de Fase Reversa/métodos , Preparações Farmacêuticas/administração & dosagem
2.
Braz. J. Pharm. Sci. (Online) ; 53(2): e16064, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839484

RESUMO

ABSTRACT Prednisone is an anti-inflammatory steroid drug widely used in clinical practice. However, no high-performance liquid chromatographic (HPLC) method has been described in the literature for the determination of prednisone in capsules until now. Thus, an HPLC method was developed using a C18 (250x4.0, 5 µm) column, with methanol:water (70:30) as mobile phase at a flow rate of 1 mL/min and detection at 240 nm. The developed method was validated following current Brazilian legislation. Additionally, linearity was assessed by evaluating the assumptions of normality, homoscedasticity, and independency of residuals, and the fit to the linear model. The method showed linearity (r2>0.99) over the range of 14.0-26.0 µg/mL, selectivity, precision (RSD<2.0%), robustness, and accuracy (average recovery of 100.05%). The chromatographic procedure was applied for assay and uniformity content determination of three different batches of prednisone capsules, showing to be suitable for their quality control.


Assuntos
Cápsulas/farmacologia , Prednisona/farmacologia , Cromatografia Líquida de Alta Pressão/métodos , Modelos Lineares , Estudo de Validação
3.
Braz. J. Pharm. Sci. (Online) ; 53(2): e16138, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839490

RESUMO

ABSTRACT The development and validation of a simple and efficient method for the quantification of ferulic acid in poly (D,L-lactide-co-glycolide) (PLGA) nanoparticles coated with chitosan (CS) by reverse phase high performance liquid chromatography coupled to photodiode array detection was described. For the chromatographic analysis, a reverse phase C-18 column was used, mobile phase consisting of acetonitrile and 0.5% acetic acid (37:63, v/v), isocratically eluted at a flow rate of 1 mL/min. Drug determination was performed at 320 nm. The method was validated in terms of the selectivity, linearity, precision, accuracy, robustness, limits of detection and quantification. The method was linear in the range of 10 to 100 µg/mL (r=0.999) and presented limit of detection and quantification of 102 ng/mL and 310 ng/mL, respectively. The method was precise (intra and inter-day) based on relative standard deviation values (less than 3.20%). The recovery was between 101.06 and 102.10%. Robustness was demonstrated considering change in mobile phase proportion. Specificity assay showed no interference from the components of nanoparticles or from the degradation products derived from acidic and oxidative conditions. The proposed method was suitable to be applied in determining the encapsulation efficiency of ferulic acid in PLGA-CS nanoparticles and can be employed as stability indicating one.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Quitosana/farmacologia , Nanopartículas/classificação , Ácidos Cumáricos/farmacologia , Estudo de Validação , Antioxidantes/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA