Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Dental press j. orthod. (Impr.) ; 28(4): e232333, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1514053

RESUMO

ABSTRACT Introduction: Superposing 3D models is an imminent need. However, current methods rely on marking multiple points on the maxilla and mandible, which could increase point marking and overlapping errors. Objective: This study aimed at developing a method for superimposing 3D models of the maxillary and mandibular arches with Autodesk Inventor® engineering software, using a single universal coordinate system (UCS) point superposition. Methods: A total of 104 STL (stereolithography) models of the maxillary and mandibular arches exported from My iTero® platform were retrospectively selected, in which T0 and T1 were the initial and refinement periods, respectively (n=26 per group). The X, Y, and Z coordinates associated with a single point in each arch were inserted into the models with SlicerCMF® software for model orientation. The arch models with UCS registration were transferred to Autodesk Inventor® for superimposition and to measure tooth movements performed during Invisalign® treatment. Arch expansion, intrusion and rotation were analyzed by two examiners. The statistics were performed using intraclass correlation coefficients (ICC), Dahlberg's formula, and t-test (p<0.05). Results: A reliable method of superimposing 3D digital models using a single UCS point in the maxilla and mandible was developed. ICC showed excellent intra- and inter-examiner correlation (ICC>0.90). A systematic error was not found concerning linear and angular measurements (<1mm and <1.5°, respectively). Digital dental movements could be analyzed, including arch expansion, dental intrusion, and tooth rotation. Conclusions: The developed method was proven reliable and reproducible for superimposing 3D models of the maxillary and mandibular arches by using UCS system.


RESUMO Introdução: A sobreposição de modelos 3D é uma necessidade iminente. No entanto, os métodos atuais dependem da marcação de múltiplos pontos na maxila e na mandíbula, o que pode aumentar a incorporação de erros no processo de sobreposição. Objetivo: O objetivo desse estudo foi desenvolver um método para sobrepor modelos 3D das arcadas superior e inferior utilizando o software de engenharia Autodesk Inventor®, por meio da marcação de um único ponto em cada arcada, usando o sistema de coordenadas universal (UCS). Métodos: No total, 104 modelos STL das arcadas superior e inferior exportados da plataforma My iTero® foram selecionados retrospectivamente, onde T0 foi o período inicial e T1, o de refinamento (n=26 por grupo). As coordenadas X, Y e Z associadas a um único ponto em cada arcada foram inseridas nos modelos usando o software SlicerCMF®. Os modelos com os pontos UCS demarcados foram transferidos para o software Autodesk Inventor® para realizar a sobreposição e medir os movimentos dentários realizados durante o tratamento com Invisalign®. Os movimentos de expansão, intrusão e rotação foram analisados por dois examinadores. A análise estatística foi realizada usando os coeficientes de correlação intra-classe (ICC), fórmula de Dahlberg e teste t (p<0,05). Resultados: Foi desenvolvido um método confiável de sobreposição de modelos digitais 3D usando um único ponto UCS na maxila e mandíbula. O ICC apresentou excelente correlação intra e inter-avaliadores (ICC>0,90). Não foi encontrado erro sistemático nas medidas lineares e angulares (<1mm e <1,5°, respectivamente). Os movimentos dentários puderam ser analisados por meio do método proposto, incluindo expansão da arcada, intrusão e rotação dentária. Conclusão: O método desenvolvido provou ser confiável e reprodutível para sobreposição de modelos 3D das arcadas superior e inferior usando o sistema UCS com marcação de ponto único.

2.
Cad. Bras. Ter. Ocup ; 31: e3374, 2023. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS, INDEXPSI | ID: biblio-1447736

RESUMO

Resumen Objetivo Validar la traducción al español chileno de la décima versión en inglés de la Dynamic Loewestein Occupational Therapy Cognitive Assessment para ser utilizado en la población chilena. Método Se realizó la tradución de el DLOTCA al español chileno. Se realizó un pilotaje para la aplicación del instrumento, para lo cual se reclutó a 40 personas adultas con una media de 42,7 años, con diversos daños cerebrales y compuesto por un 70% de mujeres y un 30% de hombres. Para evaluar la confiabilidad del instrumento se calculó el Alfa de Cronbach como medida de Consistencia Interna, aplicando 3 perspectivas, "Fiabilidad Ítem-Total", "Fiabilidad Ítem-Dominio", y "Fiabilidad Dominio-Total". Para medir la Factibilidad se identificó el porcentaje de ítems no contestados por la muestra, y el porcentaje de ítems que es identificado en las pruebas cognitivas como comprendido. Resultados La fiabilidad Ítem-Total arrojó un Alpha de Cronbach 0,953, lo que se traduce en excelente confiabilidad. La fiabilidad Ítem-Dominio, estuvo mayormente entre excelente y buena, existiendo una fiabilidad débil para los factores "orientación temporal" y "percepción visual". La fiabilidad Dominio-Total arrojó un Alpha de Cronbach 0,810 lo que se traduce en una buena confiabilidad. Finalmente, con relación a la factibilidad, los participantes respondieron el 100% de los ítems, evidenciando la accesibilidad de la traducción. Conclusiones El DLOTCA traducido al español chileno; presenta una alta confiabilidad, lo que permite obtener resultados con muy bajos sesgos, convirtiéndose en un instrumento que puede ser utilizado de manera pertinente en la población chilena.


Resumo Objetivo Validar a tradução para o espanhol chileno da décima versão em inglês do Dynamic Loewestein Occupational Therapy Cognitive Assessment (DLOTCA), para uso na população chilena. Método Após a tradução para o espanhol chileno, foi realizado um teste piloto para a aplicação do instrumento, para o qual foram recrutados 40 adultos com idade média de 42,7 anos, com lesões cerebrais diversas e composto por 70% de mulheres e 30% de homens. Para avaliar a confiabilidade do instrumento, calculou-se o Alfa de Cronbach como medida de Consistência Interna, aplicando-se três perspectivas, "Confiabilidade Item-Total", "Confiabilidade Item-Domínio" e "Confiabilidade Total-Domínio". Para medir a viabilidade, identificou-se o percentual de itens não respondidos pela amostra e o percentual de itens identificados nos testes cognitivos como compreendidos. Resultados A confiabilidade Item-Total apresentou um Alfa de Cronbach de 0,953, o que se traduz em excelente confiabilidade. A confiabilidade item-domínio ficou principalmente entre excelente e boa, com confiabilidade fraca para os fatores "orientação temporal" e "percepção visual". A confiabilidade Domínio-Total rendeu um Alfa de Cronbach de 0,810, o que se traduz em boa confiabilidade. Por fim, em relação à viabilidade, os participantes responderam 100% dos itens, evidenciando a tradução ser acessível. Conclusão A DLOTCA, traduzida para o espanhol chileno, apresenta uma alta confiabilidade, o que permite obter resultados com vieses muito baixos, tornando-se um instrumento que pode ser utilizado de forma pertinente na população chilena.


Abstract Objective To validate the Chilean Spanish translation of the tenth English version of the Dynamic Loewestein Occupational Therapy Cognitive Assessment for use in the Chilean population. Method The translation into Chilean Spanish was carried out, and then a pilot test was carried out for the application of the instrument, for which 40 adults were recruited with an average age of 42.7 years, with various brain damages and made up of 70% women and 30% men. To evaluate the reliability of the instrument, Cronbach's Alpha was calculated as a measure of Internal Consistency, applying 3 perspectives, "Item-Total Reliability", "Item-Domain Reliability", and "Domain-Total Reliability". To measure feasibility, the percentage of items not answered by the sample is identified, and the percentage of items that is identified in the cognitive tests as understood. Results The Item-Total reliability yielded a Cronbach's Alpha of 0.953, which translates into excellent reliability. Item-Domain reliability was mostly between excellent and good, with weak reliability for the factors "time orientation" and "visual perception". The Domain-Total reliability yielded a Cronbach's Alpha of 0.810, which translates into good reliability. Finally, in relation to feasibility, the participants answered 100% of the items, evidencing the translation to be accessible. Conclusion The DLOTCA translated into Chilean Spanish; it presents a high reliability, which allows obtaining results with very low biases, becoming an instrument that can be used in a pertinent way in the Chilean population.

3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;85(1): 68-76, Jan.-Feb. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1350084

RESUMO

ABSTRACT Purpose: To translate and validate the Contact Lens Dry Eyes Questionnaire (CLDEQ-8) to Portuguese language and to describe the impact of soft contact lenses on the ocular surface. Methods: We conducted a descriptive transversal study with the aim to: (1) translate and validate the CLDEQ-8 questionnaire to Portuguese language and (2) apply the CLDEQ-8 to a group of contact lens wearers along with a broad evaluation of the impact of soft contact lens on the ocular surface. The evaluation of the impact of soft contact lens was performed for a study population of 81 subjects, categorized in two groups: Group A: 61 contact lens wearers and Group B (control): 20 noncontact lens wearers. The study exclusion criteria were rigid contact lens wear, systemic or ocular diseases, the use of medications predisposing to ocular surface damage, and previous ocular surgeries. Results: For the CLDEQ-8 questionnaire translation and validation, Kappa agreement values were ³0.7 in all questions, implying a good agreement between the Portuguese and English language versions. Considering the ocular surface evaluation of the subjects, all parameters differed in Soft contact lens wearers when compared with the controls (p<0.05), except in those related to tear volume, such as the tear meniscus height and Schirmer test. Conclusions: This study provided a translated and validated Portuguese version of CLDEQ-8 questionnaire, which represents an important tool for the evolution of contact lens wearers. The broad evaluation of the ocular surface revealed an association between soft contact lens wearing and ocular surface disturbances.


RESUMO Objetivo: Traduzir e validar o questionário de olho seco e lentes de contato (CLDEQ-8) para o português e descrever o impacto das lentes de contato gelatinosas na superfície ocular. Métodos: Estudo transversal e descritivo com o objetivo de (1) traduzir e validar o CLDEQ-8 para o português e (2) aplicar o CLDEQ-8 em um grupo de usuários de lentes de contato, juntamente com uma ampla avaliação do impacto das lentes gelatinosas na superfície ocular. A avaliação do impacto das lentes gelatinosas foi realizada em uma amostra composta por 81 indivíduos, divididos em dois grupos: 61 usuários de lente de contato (Grupo A) e um grupo controle de 20 não usuários (Grupo B). Como critério de exclusão: usuário de lentes de contato rígidas, doenças sistêmicas ou oculares prévias, uso de medicamentos que podem causar danos a superfície ocular e cirurgias oculares prévias. Resultados: Para a tradução e validação do questionário CLDEQ-8, os valores de concordância Kappa foram iguais ou superiores a 0,7 em todas as perguntas, o que implica em uma boa concordância entre as versões em português e inglês. Considerando a avaliação da superfície ocular dos sujeitos, todos os parâmetros diferiram nos usuários de lente de contato em comparação com os controles (com p<0,05), exceto naqueles relacionados ao volume lacrimal, como altura do menisco lacrimal e teste de Schirmer. Conclusões: Este estudo forneceu uma versão traduzida para o português e validada do questionário CLDEQ-8, que representa uma importante ferramenta na avaliação de usuários de lente de contato. A avaliação da superfície ocular realizada demonstra a relação entre o uso de lentes de contato gelatinosas e os distúrbios da superfície ocular.

4.
RGO (Porto Alegre) ; 70: e20220056, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1406492

RESUMO

ABSTRACT Objective: Amongst other factors, the effectiveness of orthodontic treatment in children and adolescents depends on the identification of most appropriate intervention timing, which has been traditionally based on the identification of maturational stages. There is a wide variety of radiographic methods to identify these phases, either through skeletal parameters, or dental calcification. Considering that the reliability of any given assessment tool is required to enable its safe clinical use, and aiming an appropriate implementation of these parameters in future researches, this study was performed to assess the reproducibility of radiographic growth evaluation methods. Methods: Lateral teleradiographs, hand-wrist, and panoramic radiographs of sixty-eight orthodontic patients randomly selected from files of the Orthodontics Graduation Course (Guarulhos University, Guarulhos, SP, Brazil) were evaluated by two examiners to access both intra- and inter-examiner reproducibility of the assessment methods conceived by Baccetti et al.; Fishman; Greulich and Pyle; Nolla and Demirjian et al. Results: All methods analyzed showed satisfactory intra- and inter-examiner reliability. Among those that evaluated skeletal maturity, a relatively better performance was observed for Baccetti's method. Fishman's and Greulich's parameters presented similar rates, as did Nolla's and Demirjian's. Conclusion: The assessment tools analyzed presented adequate reproducibility and might potentially be used as assessment tools to evaluate children and adolescent's craniofacial growth. Further researches could evaluate the accuracy of radiographic dental calcification parameters for the identification of craniofacial growth stages.


RESUMO Objetivo: Entre outros fatores, a efetividade do tratamento ortodôntico em crianças e adolescentes depende da identificação do momento de intervenção mais apropriado, que tem sido baseado nos estágios de maturação. Uma variedade de métodos radiográficos identifica essas fases através de parâmetros esqueléticos e da calcificação dentária. Considerando que a confiabilidade de qualquer ferramenta de avaliação é necessária para permitir seu uso clínico e aplicação segura de seus parâmetros em pesquisas futuras, este estudo acessou a reprodutibilidade de métodos radiográficos de avaliação do crescimento. Métodos: Telerradiografias laterais, radiografias carpais e panorâmicas de 68 pacientes ortodônticos randomicamente selecionados dos arquivos do Curso de Graduação em Ortodontia (Universidade de Guarulhos, Guarulhos, SP, Brasil) foram avaliadas por dois examinadores para acessar a reprodutibilidade intra e inter-examinador dos métodos de avaliação concebidos por Baccetti et al.; Fishman; Greulich e Pyle; Nolla e Demirjian et al. Resultados: Todos os métodos analisados mostraram confiabilidade intra e inter-examinador satisfatória. Dentre os que avaliam maturidade esquelética, um desempenho relativamente melhor foi observado para o método de Baccetti e colaboradores. Os parâmetros de Fishman e de Greulich e Pyle apresentaram valores similares, assim como os de Nolla e de Demirjian e colaboradores. Conclusão: As ferramentas de avaliação analisadas apresentaram reprodutibilidade adequada e podem ser utilizadas para avaliação do crescimento craniofacial de crianças e adolescentes. Pesquisas futuras poderiam avaliar a acurácia dos parâmetros radiográficos de calcificação dentária para a identificação dos estágios de crescimento craniofacial.

5.
Rev. cienc. salud (Bogotá) ; 20(1): 1-17, ene.-abr. 2022. ilus, tab
Artigo em Inglês | LILACS, COLNAL | ID: biblio-1367561

RESUMO

Introduction: There has been growing interest in recent years in the cross-cultural adaptation of mea-suring instruments for various conditions treated by physiotherapy. Validation of an instrument within a target language and culture creates a final version that is conceptually and linguistically adapted to the context but remains valid and reliable. This paper describes the process of translation and cross-cul-tural adaptation of the Test of Infant Motor Performance (timp) from us English to Colombian Spanish. This was performed in accordance with international methodological guidelines. Materials and meth-ods: A group of trained translators and field experts participated in the five stages presented herein. These stages were translation and adaptation of the instrument to Colombian Spanish, validation of its content and appearance, back-translation, revision by the original author, and, finally, a pilot test.Results: The existence of two intralingual translated and revised versions of this instrument led to a more appropriate preliminary version from conceptual, discursive, and terminological perspectives. Therefore, the adjustments made in the first stage were primarily semantic. During the second stage, field experts positively assessed the translated version and suggested adjustments to grammar, spell-ing, and word choices. There were no significant discursive problems during the back-translation stage so conceptual and terminological adjustments were minor. The revision stage and the pilot test were satisfactory. Conclusion: This translation and cross-cultural adaptation was successful. The Colombian Spanish version of the measure was culturally relevant and used appropriate language, yet remained a valid and reliable tool


Introducción: la adaptación transcultural de distintos instrumentos de medición, y para diferentes tipos de condiciones en el campo de la fisioterapia, ha sido un tema de interés en los últimos años. La validación lingüística de un instrumento a una lengua y cultura meta implica que la versión final es adaptada conceptual y lingüísticamente al contexto meta. El objetivo de este artículo es describir el proceso de traducción y adaptación transcultural al español de Colombia del Test of Infant Motor Performace(timp) siguiendo los lineamientos metodológicos internacionales. Materiales y método: se conformó un grupo de traductores calificados y de expertos que participaron en cinco fases: traducción y adaptación al español de Colombia, validez de contenido y apariencia, retrotraducción, revisión por autora original y prueba piloto. Resultados: la posibilidad de contar con dos versiones intralinguales revisadas llevó a una versión preliminar más adecuada desde las perspectivas conceptual, discursiva y terminológica. Por lo tanto, los ajustes en esta fase se realizaron principalmente desde una perspectiva semántica. En cuanto a la segunda fase, los expertos validaron positivamente dicha versión y sugirieron cambiar algunas palabras y cuestiones ortográficas. La fase de retrotraducción y la validación no presentaron problemas discursivos, así que las adecuaciones conceptuales y terminológicas fueron mínimas. La fase de revisión y la prueba piloto fueron satisfactorias. Conclusión: este proceso de traducción y adaptación transcultural fue exitoso. La versión al español de Colombia fue apropiada culturalmente, además de ser una herramienta válida y confiable


Introdução: a adaptação transcultural de diferentes instrumentos de medida e para diferentes tipos de condições no campo da fisioterapia tem sido um tema de interesse nos últimos anos. A validação linguís-tica de um instrumento para uma língua e cultura alvo implica que a versão final seja conceitual e lin-guisticamente adaptada ao contexto alvo. O objetivo deste artigo é descrever o processo de tradução e adaptação transcultural para o espanhol colombiano do Test of Infant Motor Performace (timp) de acordo com as diretrizes metodológicas internacionais. Materiais e métodos: foi conformado um grupo de tradu-tores qualificados e especialistas que participaram em cinco fases: tradução e adaptação para o espanhol colombiano, validade de conteúdo e aparência, retrotradução, revisão pelo autor original e teste piloto. Resultados: a possibilidade de haver duas versões intralinguais revisadas levou a uma versão preliminar mais adequada do ponto de vista conceitual, discursivo e terminológico, portanto, os ajustes nesta fase foram feitos principalmente do ponto de vista semântico. Já na segunda fase, os especialistas validaram positivamente essa versão e sugeriram alterações em algumas palavras e problemas ortográficos. A fase de retrotradução e a validação não apresentaram problemas discursivos, portanto as adaptações conceituais e terminológicas foram mínimas. A fase de revisão e o teste pilotoforam bem-sucedidos. Conclusão: este processo de tradução e adaptação transcultural foi favorável do ponto de vista de validade e aparência para o contexto colombiano


Assuntos
Humanos , Adaptação a Desastres , Tradução , Reprodutibilidade dos Testes , Destreza Motora
6.
Investig. enferm ; 24: 1-10, 20220000. b: 5Tab
Artigo em Espanhol | LILACS, BDENF, COLNAL | ID: biblio-1402321

RESUMO

Introducción: la soledad en cuidadores familiares se presenta como una experiencia frecuente debido a las demandas que implica el cuidado de una persona con enfermedad crónica. Objetivo: determinar la validez facial y de contenido de la UCLA en cuidadores familiares de personas con enfermedad crónica. Método: estudio psicométrico de validación facial y de contenido de la escala UCLA. Para la validación del contenido participaron expertos en el área y los ítems se valoraron en términos de claridad, redundancia y relevancia. El índice Lawshe modificado por Tristán fue el estadístico usado para su análisis. Para la validación facial participaron cuidadores familiares de personas con enfermedad crónica a quienes se les realizó una entrevista cognitiva y se analizaron las áreas de comprensión, recuperación, juicio, adecuación de opciones de respuesta y contenido de la pregunta. Resultados: validez de contenido: 9 de 18 ítems de la escala UCLA presentaron IVC ajustado superior a 0,8. El ítem 8 presentó IVC ajustado de 0,66, lo que requirió análisis y ajuste semántico por parte del comité de validación. Con respecto a la validez facial, a partir del proceso de entrevista cognitiva se evidenció que para todos los ítems el 86 % o más de los participantes reportaron una adecuada comprensión, recuperación, juicio y adecuación de los ítems. Luego del análisis cualitativo de las respuestas, el ítem 7 requirió ajuste semántico. Conclusiones: la escala UCLA cuenta con la validez de contenido y facial aceptable para su uso en cuidadores de personas con enfermedad crónica en Colombia. Se propone una versión del instrumento ajustada semánticamente.


Introduction: loneliness in family caregivers is a frequent experience due to the demands of caring for a chronically ill person. Objective: to determine the face and content validity of the UCLA in family caregivers of people with chronic disease. Method: psychometric study of face and content validation of the UCLA scale. Experts in the field participated in the content validation and the items were assessed in terms of clarity, redundancy and relevance. The Lawshe index modified by Tristan was the statistic used for analysis. For face validation, family caregivers of people with chronic disease participated in a cognitive interview and the areas of comprehension, retrieval, judgment, adequacy of response options and question content were analyzed. Results: content validity: 9 of 18 items of the UCLA scale presented adjusted CVI higher than 0.8. Item 8 presented an adjusted CVI of 0.66, which required analysis and semantic adjustment by the validation committee. Regarding face validity, from the cognitive interview process it was evidenced that for all items 86% or more of the participants reported adequate comprehension, retrieval, judgment and appropriateness of the items. After qualitative analysis of the responses, item 7 required semantic adjustment. Conclusions: the UCLA scale has acceptable content and face validity for its use in caregivers of people with chronic disease in Colombia. A semantically adjusted version of the instrument is proposed.


Introdução: a solidão em cuidadores familiares apresenta-se como uma experiência frequente devido às demandas envolvidas no cuidado de uma pessoa com doença crônica. Objetivo: determinar a validade facial e conteúdo da UCLA em cuidadores familiares de pessoas com doença crônica. Método: estudo psicométrico de validação facial e de conteúdo da escala UCLA. Para a validação do conteúdo participaram especialistas na área e os itens foram avaliados quanto à clareza, redundância e relevância. O índice Lawshe modificado por Tristán foi o estatístico usado para a análise. Para a validação facial participaram cuidadores familiares de pessoas com doença crônica para quem foi realizada entrevista cognitiva e analisaram-se as áreas de compreensão, recuperação, julgamento, adequação de opções de resposta e conteúdo da pergunta. Resultados: validez de conteúdo: 9 dos 18 itens da escala UCLA apresentaram IVC ajustado superior a 0,8. O item 8 apresentou IVC ajustado de 0,66, o que exigiu análise e ajuste semântico pelo comité de validação. Em relação à validade facial, a partir do processo de entrevista cognitiva ficou claro que para todo item, o 86% ou mais dos participantes relataram adequada compreensão, recuperação, julgamento e adequação dos itens. Após a análise qualitativo das respostas, o item 7 requereu ajuste semântico. Conclusões: a escala UCLA tem validade de conteúdo e de face aceitável para seu uso em cuidadores de pessoas com docência crónica na Colômbia. Propõe-se uma versão do instrumento ajustada semanticamente.


Assuntos
Humanos , Cuidadores , Doença Crônica , Reprodutibilidade dos Testes
7.
Licere (Online) ; 24(1): 106-129, 20210317. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1179165

RESUMO

This study aimed to detail and analyse the design, evaluation and outcomes of leisure education programs. Each program was designed for a particular population with specific set of components, principles and goals. Some techniques were identified as useful to assist deliverers in effectively providing these services (e.g. contents, deliverers, delivery methods, settings and duration), which are essential aspects to consider when preparing and planning leisure education. In general, these programs may have a positive influence on diverse audiences, highlighting the potential of leisure-related activities engagement. Additionally, an evaluation of the used instruments was performed given that selecting an adequate instrument may determine the quality of reporting and whether a program may effectively broaden leisure-related experiences. We hope to contribute to the processes of developing such programs.


Este estudo objetivou detalhar e analisar a concepção, avaliação e resultados de programas de educação para o lazer. Cada programa foi projetado para uma determinada população com um conjunto específico de componentes, princípios e objetivos. Algumas técnicas foram identificadas como úteis para auxiliar os distribuidores na prestação eficaz desses serviços (por exemplo, conteúdos, distribuidores, métodos de entrega, configurações e duração), os quais são aspectos essenciais a serem considerados ao preparar e planejar a educação para o lazer. Em geral, esses programas podem ter uma influência positiva em diversos públicos, destacando o potencial de engajamento em atividades do âmbito do lazer. Além disso, foi realizada uma avaliação dos instrumentos utilizados, visto que a escolha de um instrumento adequado pode determinar a qualidade do relato, bem como se um programa pode efetivamente ampliar as vivências da esfera do lazer. Espera-se que o presente estudo possa contribuir com os processos de desenvolvimento de tais programas.


Assuntos
Atividades de Lazer , Educação
8.
Ciênc. Saúde Colet. (Impr.) ; Ciênc. Saúde Colet. (Impr.);26(3): 1047-1061, mar. 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1153846

RESUMO

Abstract This study analyzed the validity and reliability of an instrument with scales measuring factors associated with screen time in adolescents. Two cross-sectional studies included students for analyses of validity and internal consistency (n=1138, 51.5% boys) and test-retest reproducibility (n=194, 56.2% boys). Individual (attitude, self-efficacy and expectations), social (behaviors, rules, beliefs and family support and support of school members) and physical environmental (home and bedroom equipment) factors of screen time were evaluated. All the scales of the instrument met the statistical criteria of the validity of the exploratory factorial analysis (p<0.001). The exploratory factorial analysis indicated five one-dimensional and three two-factor scales (self-efficacy, expectations and familiar behavior), with factorial loads of 0.56 to 0.88. There were significant correlations between the scores of almost all the scales and the reported screen time (p<0.05). Eight of nine scales/subscales showed Cronbach's α value being higher than 0.70, and ICC ranged from 0.63 to 0.83. In conclusion, the instrument presented scales with acceptable validity and reliability and can be used to measure factors associated with screen time in Brazilian students.


Resumo Este estudo analisou a validade e a confiabilidade de um instrumento com escalas de fatores associados ao tempo de tela em adolescentes. Dois estudos transversais incluíram escolares para análises de validade (n=1138, 51,5% meninos) e reprodutibilidade teste-reteste (n=194, 56,2% meninos) do instrumento. Fatores individuais (atitude, autoeficácia e expectativas), do ambiente social (comportamentos, regras, crenças e suporte familiar e suporte dos membros da escola) e físico (casa e no quarto) associados ao tempo de tela foram avaliados. Todas as escalas do instrumento atenderam os critérios estatísticos de validade da análise fatorial exploratória (p<0.001). A análise fatorial exploratória indicou cinco escalas unidimensionais e três bi-dimensionais (autoeficácia, expectativas e comportamento familiares), com cargas fatoriais de 0,56 a 0,88. Houve correlações significativas entre quase todas as escalas e o tempo de tela reportado (p<0,05). Oito das nove escalas apresentaram um valor de α de Cronbach superior a 0,70, e o CCI variou de 0,63 a 0,83. O instrumento apresentou escalas que se apresentaram com validade e confiabilidade aceitáveis, podendo ser utilizado na mensuração de fatores associados ao tempo de tela em escolares brasileiros.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Estudantes , Tempo de Tela , Psicometria , Brasil , Estudos Transversais , Inquéritos e Questionários , Reprodutibilidade dos Testes
9.
Rev. Fac. Nac. Salud Pública ; 38(3): e338085, sep.-dic. 2020. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1288004

RESUMO

Resumen Objetivo: Establecer la validez de criterio de una herramienta para la detección de la pérdida auditiva en población infantil colombiana. Metodología: Estudio de concordancia en 160 niños entre 5 y 10 años, a quienes se les valoró la audición mediante dos pruebas: la "Herramienta de detección de bajo costo para identificar y clasificar la pérdida auditiva", diseñada en Brasil, y la "Audiometría tonal" como prueba de oro. Se determinó la sensibilidad y la especificidad de la herramienta y la estimación de la concordancia entre las dos pruebas mediante el índice de kappa. Resultados: La "Herramienta de detección de bajo costo para identificar y clasificar la pérdida auditiva" presentó una sensibilidad del 35 %, especificidad del 25 %, un valor predictivo positivo del 12 %, valor predictivo negativo del 56 % y un índice de kappa de -0,24. Conclusión: La "Herramienta de detección de bajo costo para identificar y clasificar la pérdida auditiva" presenta poca capacidad para clasificar correctamente al enfermo como verdadero enfermo y al sano como verdadero sano. Además, la pobre concordancia entre las dos pruebas no permite clasificarla como una herramienta válida para la identificación y la clasificación de la pérdida auditiva en población infantil colombiana. Por lo anterior, se recomienda que cualquier método de tamizaje o de diagnóstico debe cumplir con el proceso de validación antes de ser aplicado en la población. La prevalencia de hipoacusia encontrada fue del 23,1 %.


Abstract Objective: To establish the criteria validity of a tool to detect hearing loss in Colombian children. Methodology: Concordance study in 160 children between 5-10 years old who had their hearing assessed using two tests: the "Low-cost detection tool to identify and classify hearing loss", designed in Brazil, and the "Tonal Audiometry" as the gold standard. The sensitivity and specificity of the tool and the estimation of the agreement between the two tests were determined using the kappa index. Results: The "Low cost detection tool to identify and classify hearing loss" presented a sensitivity of 35%, specificity of 25%, a positive predictive value of 12%, negative predictive value of 56% and a kappa index of -0.24. Conclusion: The "Low-cost detection tool to identify and classify hearing loss" has little capacity to correctly classify the patient as truly ill and the healthy as truly healthy. Furthermore, the poor concordance between the two tests does not allow it to be classified as a valid tool for identifying and classifying hearing loss in Colombian children. It is therefore recommended that any screening or diagnostic method must comply with the validation process before being applied to the population. The prevalence of hearing loss found was 23.1%.


Resumo Objetivo: Estabelecer a validade de critério de uma ferramenta para a detecção da perda auditiva na população infantil colombiana. Metodologia: Estudo de concordância em 160 crianças com idades entre 5 e 10 anos, cuja audição foi avaliada através de dois testes: a "Ferramenta de detecção de baixo custo para identificar e classificar a perda auditiva" desenhada no Brasil, e a "Audiometria tonal" como exame padrão-ouro. Determinou-se a sensibilidade e a especificidade da ferramenta, e a estimativa entre as duas avaliações foi feita através do coeficiente de concordância Kappa. Resultados: A "ferramenta de detecção de baixo custo para identificar e classificar a perda auditiva" apresentou uma sensibilidade de 35%, especificidade de 25%, um valor preditivo positivo de 12%, valor preditivo negativo de 56% e coeficiente de concordância Kappa de -0,24. Conclusão: A "ferramenta de detecção de baixo custo para identificar e classificar a perda auditiva" apresenta pouca capacidade para classificar corretamente o doente como verdadeiro doente e ao sadio como verdadeiro sadio. Além disso, a pobre concordância entre os dois exames não permite classificá-la como uma ferramenta válida para a identificação e a classificação da perda auditiva na população infantil colombiana. Considerando estes resultados, recomenda-se que qualquer método de triagem auditiva ou de diagnóstico, deve cumprir com o proceso de validação antes de ser aplicado na população. A prevalência de perda auditiva encontrada foi de 23,1%.

10.
Radiol. bras ; Radiol. bras;53(5): 314-319, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1136104

RESUMO

Abstract Objective: The present study aims to perform a reproducibility study of the clivus-canal angle (CCA), Welcker's basal angle (WBA), and the distance from the odontoid process to Chamberlain's line (DOCL) on magnetic resonance imaging (MRI). Materials and Methods: Two medical students and two radiologists respectively evaluated 100 and 50 consecutive MRI scans of adult skulls, selected randomly. Each examiner, working independently and blinded to the previous results, performed readings for each patient on two different occasions. Measurements were performed in T1-weighted sequences acquired in the midsagittal plane. The levels of intraobserver reproducibility and interobserver agreement were evaluated by calculating the intraclass correlation coefficients (ICCs) and the corresponding 95% confidence intervals. Results: The mean values obtained by the examiners were 150° for the CCA, 130° for the WBA, and 2.5 mm for the DOCL. The ICC for interobserver agreement was 0.980, 0.935, and 0.967, for the CCA, WBA, and DOCL, respectively, for the students, compared with 0.977, 0.941, and 0.982, respectively, for the radiologists, and 0.980, 0.992, and 0.990, respectively, for all of the examiners together. In the analysis of intraobserver agreement, the ICC ranged from 0.929 to 0.959 for the CCA, from 0.918 to 0.964 for the WBA, and from 0.918 to 0.981 for the DOCL. Conclusion: The measurement of the CCA, WBA, and DOCL appears to show excellent intraobserver reproducibility and interobserver agreement on MRI.


Resumo Objetivo: Realizar um estudo de reprodutibilidade do ângulo clivocanal (ACC), ângulo basal de Welcker (ABW) e distância do odontoide à linha de Chamberlain (DOLC) em ressonância magnética (RM). Materiais e Métodos: Quatro examinadores, dois graduandos de medicina e dois radiologistas, avaliaram, respectivamente, 100 e 50 indivíduos adultos submetidos a RM de crânio, consecutiva e aleatoriamente. Cada um realizou duas leituras para cada paciente em diferentes ocasiões, de forma cega e independente. As análises de concordância intraobservador e interobservador foram realizadas pelo coeficiente de correlação intraclasse (CCI), com intervalo de confiança de 95%. Resultados: As medidas médias, considerando todos os examinadores, foram: ACC = 150°, ABW = 130°, DOLC = 2,5 mm. A análise interobservador entre os estudantes revelou CCI de 0,980, 0,935 e 0,967 para ACC, ABW e DOLC, respectivamente, e para os radiologistas, CCI de 0,977, 0,941 e 0,982, respectivamente. A análise interobservador entre estudantes e radiologistas revelou CCI de 0,980, 0,992 e 0,990, respectivamente. Em relação à análise intraobservador, as medidas do ACC tiveram CCI variando entre 0,929 e 0,959, ABW entre 0,918 e 0,964 e DOLC entre 0,918 e 0,981. Conclusão: ACC, ABW e DOLC obtiveram excelentes reprodutibilidades intraobservador e interobservador na RM.

11.
Rev. panam. salud pública ; 42: e65, 2018. tab
Artigo em Espanhol | LILACS | ID: biblio-961816

RESUMO

RESUMEN Objetivos Exponer las ventajas de la utilización del alfa ordinal para situaciones en que no se cumplan los supuestos del alfa de Cronbach y mostrar la utilidad del alfa ordinal con la versión chilena del AUDIT, así como proporcionar los comandos en el lenguaje de programación R para realizar los cálculos respectivos. Métodos Se compararon el alfa de Cronbach y el alfa ordinal en el caso del cuestionario AUDIT aplicado a 419 estudiantes de una universidad chilena. Resultados En todos los dominios, el alfa ordinal resultó ser mayor que el alfa de Cronbach, lo que es congruente con lo encontrado en la bibliografía. Al considerar el alfa ordinal se acepta la confiabilidad de cada uno de los dominios y de la encuesta completa, lo que no ocurre completamente al trabajar con el alfa de Cronbach. Conclusiones Para tomar decisiones sobre la confiabilidad de una dimensión se debe considerar un índice que cumpla los supuestos necesarios para su utilización, ya que no hacerlo puede desembocar en conclusiones erróneas y afectar de manera notable el desarrollo de una investigación. Los valores del alfa de Cronbach subestiman la confiabilidad de un instrumento al trabajar con escalas ordinales.


ABSTRACT Objectives Demonstrate the advantages of using ordinal alpha when the assumptions for Cronbach's alpha are not met; show the usefulness of ordinal alpha with the Chilean version of the WHO Alcohol Use Disorders Identification Test (AUDIT); and provide the commands in R programming language for performing the respective calculations. Methods Cronbach's alpha and ordinal alpha were compared in an AUDIT questionnaire administered to 419 students at a Chilean university. Results In all domains, the result using ordinal alpha was greater than with Cronbach's alpha. This finding was consistent with the literature on the subject. When ordinal alpha was chosen, the reliability of each domain and the survey as a whole was accepted, which does not always happen with Cronbach's alpha. Conclusions In making decisions about the reliability of a dimension, consideration should be given to an index that meets the required assumptions for using it in order to avoid erroneous conclusions that can have an appreciable effect on research. The values of Cronbach's alpha underestimate the reliability of an instrument when working with ordinal scales.


RESUMO Objetivos Apresentar as vantagens do uso do alfa ordinal nos casos em que não são cumpridos os pressupostos do alfa de Cronbach e demonstrar a utilidade do alfa ordinal com a versão chilena do instrumento AUDIT e criar comandos na linguagem de programação R para realizar os respectivos cálculos. Métodos Foi realizada a comparação entre o alfa de Cronbach e o alfa ordinal com o uso do instrumento AUDIT aplicado a 419 alunos de uma universidade chilena. Resultados Em todos os domínios, o alfa ordinal foi maior que o alfa de Cronbach, o que é condizente com o descrito na literatura. Ao considerar o alfa ordinal, aceita-se a confiabilidade de cada um dos domínios e da pesquisa completa, o que não ocorre completamente quando se usa o alfa de Cronbach. Conclusões Para tomar decisões sobre a confiabilidade de uma dimensão, deve-se considerar um índice que cumpra os pressupostos necessários para seu uso, porque do contrário pode-se chegar a conclusões errôneas e afetar consideravelmente o desenvolvimento de uma pesquisa. Os valores do alfa de Cronbach subestimam a confiabilidade do instrumento por se basear em escalas ordinais.


Assuntos
Humanos , Consumo de Bebidas Alcoólicas , Estudo de Validação , Chile , Reprodutibilidade dos Testes
12.
Pensam. psicol ; 15(2): 7-14, jul.-dic. 2017. tab
Artigo em Espanhol | LILACS | ID: biblio-895189

RESUMO

Objetivo. Conocer la estructura interna y la contabilidad de la escala breve de Francis para religiosidad (Francis-5) en estudiantes de Medicina de una universidad de Bucaramanga, Colombia. Método. Se realizó un análisis factorial exploratorio en el que participaron 365 estudiantes, entre los 18 y los 30 años de edad (M = 20.12; DE = 1.93). La validez nomológica se probó al comparar las puntuaciones según sexo y filiación religiosa de los participantes. La consistencia interna se evaluó con alfa de Cronbach. Resultados. Se observó una dimensión responsable del 88.4% de la varianza, con puntuaciones mayores en mujeres que en hombres (M = 16.70, DE = 5.03 frente a M = 15.35, DE = 5.51; t = 2.41, p = 0.016); en cristianos no católicos (M = 18.26, DE = 4.26) que en otras filiaciones (M = 16.68, DE = 4.28); y en católicos en relación con (M = 12.86, DE = 7.53) otras filiaciones (M = 8.00, DE = 7.38) y sin filiación religiosa (F = 32.84, p < 0.001), con un a = 0.97. Conclusión. Francis-5 es un instrumento válido y confiable para cuantificar religiosidad en estudiantes de Medicina. Futuras investigaciones deben determinar otras medidas de validez y confiabilidad.


Objective. To understand the internal consistency reliability of a five-item form of the Francis scale toward Christianity (Francis-5) in medical students from a university in Bucaramanga, Colombia. Method. A validation study was conducted in which 365 students participated, aged between 18 and 30 years-old (M = 20.12, SD = 1.93). An exploratory factor analysis was performed for construct validity. Nomological validity was tested by comparing scores by gender and religious affiliation. Internal consistency was assessed with Cronbach alpha. Results. One dimension accounted for 88.4% of the total variance; higher scores were observed in women than in men (M = 16.70, SD = 5.03 vs. M = 15.35, SD = 5.51, t = 2.41; p = 0.016), and in non-Catholic Christian affiliations (M = 18.26; SD = 4.26) than other (M = 16.68, SD = 4.28 among Catholics versus M = 12.86; SD = 7.53 among other filiations and M = 8.00, SD = 7.38 among none filiation, F = 32.849, p<0.001), and alpha was 0.97. Conclusion. Francis-5 is a reliable instrument for measuring religiosity in medical students from a university in Bucaramanga, Colombia. Further research should determine other measures of validity and reliability for the scale.


Escopo. Conhecer a estrutura interna e confiabilidade da escada breve de Francis para a religiosidade (Francis-5) em estudantes de medicina de uma universidade de Bucaramanga, Colômbia. Metodologia. Foi feita uma análise fatorial exploratória na que participaram 365 estudantes, entre os 18 e 30 anos de idade (M = 20.12 anos; DE = 1.93). A validez nomológica foi provada ao comparar as pontuações segundo o sexo e a filiação religiosa dos participantes. A consistência interna foi avaliada com alfa de Cronbach. Resultados. Foi observada uma dimensão responsável do 88.4% de variação, com pontuação maiores em mulheres do que em homens (M = 16.70, DE = 5.03 frente a M = 15.35, DE = 5.51, t = 2.41, p = 0.016) e em cristãos não católicos (M = 18.26, DE = 4.26) que em outras filiações (M = 16.68, DE = 4.28), em católicos em relação com (M = 12.86, DE = 7.53) outras filiações e(M = 8.00, DE = 7.38) sem filiação religiosa (F = 32.84, p < 0.001); com um alpha de 0.97. Conclusão. Francis-5 é um instrumento válido e confiável para quantificar religiosidade em estudantes de medicina. Futuras pesquisas devem determinar outras medidas de validez e confiabilidade.


Assuntos
Humanos , Estudantes de Medicina , Reprodutibilidade dos Testes , Cristianismo , Estudo de Validação
13.
Rev. Fac. Nac. Salud Pública ; 35(3): 335-342, sep.-dic. 2017. tab
Artigo em Espanhol | LILACS | ID: biblio-896886

RESUMO

Resumen Objetivo: evaluar la reproducibilidad de un instrumento para la medición de factores de riesgo de cáncer de piel. Métodos: tomando como base algunas variables encontradas en la literatura para medir factores de riesgo de cáncer de piel, se hicieron grupos focales con pacientes y con expertos, para obtener las preguntas de un instrumento de recolección de datos. Posteriormente, se evaluó la reproducibilidad prueba-reprueba en 85 casos (cáncer de piel) y 85 controles de los ítems seleccionados. Para el análisis se utilizaron los estadísticos kappa, kappa ponderado y coeficiente de correlación de Lin. Resultados: las variables con mayor confiabilidad fueron municipio de residencia (0,86-0.98) y la ocupación al aire libre (0,78-0,83). La variable con menor confiabilidad fue el uso de elementos de protección solar (0,53-0,8). Conclusiones: las variables evaluadas tienen unos niveles de confiabilidad buenos, lo cual es una de las condiciones que se deben tener en cuenta para que sean usadas en la identificación de los factores de riesgo para desarrollar cáncer de piel en nuestra población de una manera más válida.


Abstract Objective: to evaluate the reproducibility of an instrument for measuring skin cancer risk factors. Methodology: some variables for measuring skin cancer risk factors were found in the literature and used as a starting point to conduct focus groups with patients and experts in order to obtain the questions for a data collection instrument. Subsequently, test-retest reproducibility was evaluated with 85 cases (skin cancer) and 85 controls for the selected items. Finally, the kappa, weighted kappa and Lin correlation coefficients were used for the analysis. Results: the most reliable variables were municipality of residence (0.86-0.98) and working outdoors (0.78-0.83). The least reliable variable was using sun protection gear (0.53-0.8). Conclusions: the evaluated variables have good reliability levels, which is one of the conditions that must be taken into account in order to identify risk factors for developing skin cancer among our population in a more valid way.


Resumo Objetivo: Avaliar a reprodutibilidade de um instrumento para a medição de fatores de risco de câncer de pele. Metodologia: Estabeleceram-se como base algumas variáveis encontradas na literatura para medir fatores de risco de câncer de pele, realizaram-se grupos focais com pacientes e com especialistas com o propósito de obter as perguntas de um instrumento de coleta de dados. Posteriormente, foi avaliada a reprodutibilidade teste-reteste em 85 casos (câncer de pele) e 85 controles dos elementos selecionados. Para a análise foram utilizados os estatísticos kappa, kappa ponderado e coeficiente de correlação de Lin. Resultados: as variáveis com maior confiabilidade foram município de moradia (0,86-0.98) e a ocupação ao ar livre (0,78-0,83). A variável com menor confiabilidade foi o uso de elementos de proteção solar (0,53-0,8). Conclusões: as variáveis avaliadas possuem bons elementos de confiabilidade, essa é uma das condições que precisam ser levadas em consideração para que sejam usadas na identificação dos fatores de risco para desenvolver câncer de pele em nossa zona de moradia de uma maneira mais válida.

14.
Aquichan ; 17(2): 183-194, abr.-jun. 2017. graf
Artigo em Espanhol | LILACS, BDENF, RHS | ID: biblio-887280

RESUMO

RESUMEN Objetivo: validar las escalas de Bienestar Psicológico de Ryff en enfermería y relacionarlas con variables clave en calidad de vida laboral. Materiales y métodos: participaron por encuesta electrónica, autoadministrada anónima, 433 profesionales, 33,1% de ellos profesionales de enfermería (n = 123) en quienes se realizó el estudio. Además de los datos sociodemográficos, se recogió información sobre bienestar psicológico, atención consciente, afrontamiento de la muerte y calidad de vida. La validez de constructo fue evaluada con análisis factorial confirmatorio. Se estimó fiabilidad y se recogieron evidencias de validez externa. Resultados: el modelo mostró ajuste adecuado: X2(362) = 438,59 (p = 0,01), CFI = 0,98, RMSEA = 0,05 (0,03-0,06) y fiabilidad adecuada para todas las dimensiones, excepto autonomía. Las dimensiones de bienestar se relacionaron moderada y positivamente con autoconciencia, afrontamiento ante la muerte y satisfacción por compasión, y negativamente con fatiga por compasión y burnout. Se destacan las relaciones entre dominio del entorno y burnout (-0,54) y propósito en la vida con satisfacción (0,54) y con afrontamiento de la muerte (0,50). Conclusiones: los resultados apoyan el uso de estas escalas en enfermería, pues muestran adecuada fiabilidad y validez, y varias de ellas explican hasta una cuarta parte de indicadores relevantes en salud laboral como burnout o satisfacción vital.


ABSTRACT Objective: The study was intended to validate Ryff's psychological well-being scales in nursing and to relate them to key variables in the quality of life at work. Materials and method: Four hundred thirty-three (433) professionals took part through an anonymous, self-administered electronic survey; 33.1% were nursing professionals (n = 123) and the authors focused on them. In addition to sociodemographic data, information was collected on psychological well-being, mindfulness, coping with death, and quality of life. Construct validity was evaluated through confirmatory factor analysis. Reliability was estimated and evidence of external validity was collected. Results: The model showed adequate adjustment: X2(362) = 438.59 (p = 0.01), CFI = 0.98, RMSEA = 0.05 [0.03-0.06] and adequate reliability for all the dimensions except autonomy. The dimensions of well-being were moderately and positively with self-awareness, coping with death, and satisfaction from compassion, and negatively with fatigue from compassion and burnout. The association between dominance of the environment and burnout (-0.54), purpose in life and satisfaction (0.54) and coping with death (0.50) stood out. Conclusions: The results support the use of these scales in nursing, since they demonstrate adequate reliability and validity. In fact, several of them explain up to a quarter of the relevant indicators in occupational health, such as burnout or satisfaction with life.


RESUMO Objetivos: validar as escalas de Bem-estar Psicológico de Ryff em enfermagem e relacioná-las com variáveis fundamentais em qualidade de vida no trabalho. Materiais e método: participaram por enquete eletrônica autoadministrada anônima 433 profissionais - 33,1 % profissionais de enfermagem (n=123), nos quais nos focamos. Além de informação sociodemográfica, coletou-se informação sobre bem-estar psicológico, atenção consciente, enfrentamento da morte e qualidade de vida. A validade de constructo foi avaliada com análise fatorial confirmatória. Estimou confiabilidade e coletaram-se evidências de validade externa. Resultados: o modelo mostrou ajuste adequado: X2(362) = 438,59 (p = 0,01), CFI = 0,98, RMSEA = 0,05 [0,03-0,06] e confiabilidade adequada para todas as dimensões, exceto autonomia. As dimensões do bem-estar foram relacionadas moderada e positivamente com autoconsciência, enfretamento da morte e satisfação por compaixão, e negativamente com fatiga por compaixão e burnout. Destacam-se as relações entre domínio do ambiente e burnout (-0,54), propósito na vida com satisfação (0,54) e com enfrentamento da morte (0,50). Conclusões: os resultados apoiam o uso dessas escalas em enfermagem, pois mostram adequada confiabilidade e validade, e várias delas explicam até um quarto de indicadores relevantes em saúde do trabalho, como burnout ou satisfação vital.


Assuntos
Humanos , Pesquisa em Enfermagem , Avaliação de Recursos Humanos em Saúde , Psicometria , Espanha , Condições de Trabalho
15.
Dental press j. orthod. (Impr.) ; 22(1): 65-74, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-840207

RESUMO

ABSTRACT Objectives: The accuracy and reliability of plaster models and digital models acquired with two different surface laser scanners were tested by means of three methods: measurement with calipers, digital measurement with proper software and superimposition of the digital models. Methods: Thirty plaster models with permanent dentition that met the inclusion criteria were selected and scanned with two laser scanners (R700 and Xcad). Three examiners measured distances on plaster models with a digital caliper and on digital models using Ortho Analyzer software. The digital models were also compared by means of superimposition of the models using the Geomagic Qualify software. The intra and inter-examiner reliability of the measurements were evaluated using the ICC. Paired t test was used to test the accuracy of the measurements on digital and plaster models. Results: The measurements on plaster and digital models acquired by two different scanners showed high values for the ICC. Although statistically significant differences between the measurements on plaster and digital models have been found, these discrepancies were not considered clinically relevant. The superimposition method with Geomagic Qualify software showed that the two digital models were not significantly different. Conclusions: Digital models created from scanned plaster models using the R700 or Xcad scanners were clinically accurate according to the two methods of comparison used.


RESUMO Objetivos: a acurácia e a confiabilidade de modelos de gesso e modelos digitais adquiridos por dois diferentes scanners de superfície a laser foram testadas com três métodos: medição com paquímetro, medição com programa específico e sobreposição de modelos digitais. Métodos: trinta modelos de gesso com dentição permanente que preencheram os critérios de inclusão predeterminados foram selecionados e escaneados com dois diferentes scanners a laser (R700 e Xcad). Três examinadores mediram distâncias selecionadas nos modelos de gesso usando um paquímetro digital e, nos modelos digitais, usando o programa Ortho Analyzer. Os modelos digitais também foram comparados por sobreposição de modelos, com o programa Geomagic Qualify. A confiabilidade intra e interexaminadores das medições foi avaliada por meio do coeficiente de correlação intraclasse (ICC). O teste t pareado foi utilizado para avaliar a acurácia das medições nos modelos de gesso e digitais. Resultados: as medições nos modelos de gesso e nos modelos digitais escaneados pelos dois diferentes scanners apresentaram valores elevados para o ICC. As diferenças estatisticamente significativas encontradas entre as medições nos modelos de gesso e nos modelos digitais não foram consideradas clinicamente relevantes. O método de sobreposição de modelos com o programa Geomagic Qualify demonstrou que os dois tipos de modelos digitais não foram significativamente diferentes. Conclusões: os modelos digitais criados a partir do escaneamento dos modelos de gesso com os scanners R700 e Xcad foram clinicamente precisos, de acordo com os dois métodos de comparação utilizados.


Assuntos
Humanos , Simulação por Computador , Reprodutibilidade dos Testes , Modelos Dentários , Sulfato de Cálcio , Variações Dependentes do Observador , Estudos de Validação como Assunto
16.
Fisioter. pesqui ; 23(2): 142-147, abr.-jun. 2016. tab
Artigo em Português | LILACS | ID: lil-795194

RESUMO

RESUMO O Gross Motor Function, traduzido para o português como Sistema de Classificação da Função Motora Grossa (GMFCS), tem se mostrado confiável para classificar a função motora grossa de crianças com paralisia cerebral (PC). Porém, a confiabilidade da versão brasileira ainda é pouco estabelecida no país, especialmente entre diferentes profissionais e estudantes de graduação na área de saúde. O objetivo deste estudo foi avaliar a confiabilidade da versão brasileira do GMFCS por estudantes e profissionais da área de saúde (fisioterapeutas e terapeutas ocupacionais), com diferentes níveis de experiência. Foram realizadas filmagens da função motora grossa de 30 crianças com PC entre 4 e 18 anos acompanhadas pelo serviço de neurologia ou reabilitação de um hospital no interior paulista. Os vídeos foram enviados a estudantes de uma universidade pública e profissionais da área de fisioterapia (FT) e terapia ocupacional (TO) que compuseram 3 grupos (grupo 1: 1 FT e 1 TO com mais de 5 anos de experiência em neurologia; grupo 2: 1 FT e 1 TO com até dois anos de experiência; grupo 3: um estudante de graduação em FT e 1 de TO). O coeficiente kappa foi utilizado para avaliar a confiabilidade entre os grupos. Concordância quase perfeita foi obtida no grupo 1 [K=0,83; IC 95% (0,68-0,98)] e substancial para os grupos 2 e 3 [K=0,79; IC 95% (0,63-0,95) e K=0,67; IC 95% (0,48-0,86) respectivamente]. O GMFCS E & R se mostrou confiável para ser utilizado por profissionais da saúde de diferentes áreas e níveis de experiência profissional, inclusive por estudantes de graduação, auxiliando-os na compreensão da heterogeneidade da PC.


RESUMEN En la clasificación de la función motora gruesa de niños con parálisis cerebral (PC), el Gross Motor Function viene siendo fiable, sin embargo la versión brasileña todavía sigue siendo poco aplicada, en especial por distintos profesionales y estudiantes de grado en el área de la salud. El propósito de este artículo es el de evaluar la fiabilidad de esta versión para estudiantes y profesionales del área de la salud (fisioterapeutas y terapeutas ocupacionales), con distintos niveles de experiencia. Se captaron video-imágenes de la función motora gruesa de treinta niños con PC entre 4 y 18 años de edad, acompañados por el servicio de neurología o por la rehabilitación de un hospital en el interior de São Paulo, y se las enviaron a los estudiantes de una universidad pública y a los profesionales del área de fisioterapia (FT) y terapia ocupacional (TO), los cuales formaron tres grupos: Grupo 1 con 1 FT y 1 TO cuya experiencia en neurología era de más de cinco años; Grupo 2 con 1 FT y 1 TO y la experiencia hasta dos años; y Grupo 3 con 1 estudiante de grado en FT y 1 en TO. Se empleó el coeficiente kappa para evaluar la fiabilidad de los grupos. Los resultados mostraron concordancia casi positiva para el Grupo 1 [K=0,83; IC 95% (0,68-0,98)] y sustancial para los grupos 2 y 3 [K=0,79; IC 95% (0,63-0,95) y K=0,67; IC 95% (0,48-0,86), respectivamente]. Se concluye que el GMFCS E & R es fiable para emplearse por los profesionales en diferentes áreas de la salud, así como con distintos niveles de experiencia, incluso por estudiantes de grado, lo que les ayuda en el trabajo con el PC.


ABSTRACT The Gross Motor Function Classification System has been reliable to classify the gross motor function of children with cerebral palsy (CP); however, the reliability of the Portuguese version (Brazil) is not entirely established in the country, especially among different health professionals and undergraduate students. The aim of this study was to evaluate the reliability of the Portuguese version (Brazil) of the GMFCS E&R by students and health professionals (physical and occupational therapists), with different levels of experience. The gross motor function of 30 children with CP between 4 and 18 years was filmed, accompanied by the neurology service or rehabilitation of a hospital in São Paulo's countryside. The videos were sent to students of a public university and to physical (PT) and occupational therapy (OT) professionals that composed three groups (Group 1: 1 PT and 1 OT with more than 5 years of experience in neurology; Group 2: 1 PT and 1 OT with up to two years of experience; Group 3: an undergraduate student of PT and 1 of OT). The kappa coefficient was used to evaluate reliability among the groups. Almost perfect agreement was obtained in Group 1 [K=0.83; 95%CI (0.68-0.98)] and substantial was obtained in groups 2 and 3 [K=0.79; 95%CI (0.63-0.95) and K=0.67; 95%CI (0.48-0.86), respectively]. The GMFCS E&R proved reliable for use by health professionals of different areas and levels of experience, including undergraduate students, helping them to understand the heterogeneity of CP.

17.
Fisioter. pesqui ; 22(4): 378-385, out.-dez. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-775747

RESUMO

RESUMO A força de preensão palmar é uma medida influenciada por diversos fatores como sexo, idade, motivação, treinamento muscular, dominância, altura, peso, variáveis socioeconômicas, participação em esportes específicos ou profissões. Pode ser mensurado por meio da dinamometria ou por medidores de tensão como as células de carga (strain gauges ). Confiabilidade e validade são importantes propriedades psicométricas que avaliam a reprodutibilidade da medida de um instrumento e sua aplicabilidade. Desse modo, o objetivo deste estudo foi avaliar a confiabilidade teste-reteste e a validade de constructo de uma célula de carga para medida da força de preensão palmar isométrica, em voluntários assintomáticos e portadores de disfunções no punho e mão. Foram utilizados métodos padronizados de posicionamento do membro superior e realizada aleatorização da ordem das coletas. A análise estatística de confiabilidade foi realizada pelo ICC e a validade de constructo pelo coeficiente de correlação de Pearson (r), com p <0,05, com IC de 95%, utilizando o SPSS versão 20(r). A amostra constou de 24 voluntários saudáveis com idade média de 22,25 anos, todos universitários, e 21 voluntários portadores de disfunções do membro superior e mão, de ambos os sexos. A confiabilidade teste-reteste para o grupo dos indivíduos assintomáticos foi ICC 0,90 (0,78-0,95), no grupo dos portadores de disfunções do punho e mão o ICC encontrado foi 0,94 (0,87-0,97), ambos considerados excelentes. Os gráficos de Bland e Altman mostraram que, embora a confiabilidade apresentasse níveis excelentes e com baixos valores de erro padrão de medida, alguns dados discrepantes foram encontrados. Os coeficientes de correlação de Pearson foram altos tanto para o grupo de indivíduos assintomáticos (r=0,85), como para o grupo de pacientes (r=0,83). Conclusão: baseado nos achados da amostra analisada é sugerido que a célula de carga seja um dispositivo confiável e válido para a medida de força de preensão palmar isométrica da mão, podendo ser utilizado em futuros estudos e na prática clínica.


RESUMEN La fuerza de prensión palmar es una medida influida por diversos factores tales como, sexo, edad, motivación, entrenamiento muscular, dominio, altura, peso, variables socioeconómicas, participación en deportes específicos o profesiones. Se la puede medir mediante la dinamometría o por medidores de tensión como las células de carga (strain gauges ). La fiabilidad y la validez son importantes propiedades psicométricas que evalúan la reproducibilidad de un instrumento de medición y su aplicabilidad. De esa manera, este estudio tuvo la pretensión de evaluar la fiabilidad test-retest y la validez del constructo de una célula de carga para medir la fuerza de prensión palmar isométrica, en participantes asintomáticos y en portadores de trastornos de la muñeca y de la mano. Se utilizaron métodos estandarizados de posicionamientos del miembro superior y se llevó a cabo la aleatorización del orden de la recolección de datos. El análisis estadístico de fiabilidad fue realizado por el ICC y la validez del constructo por el coeficiente de correlación de Pearson (r), con p<0,05, con IC de 95%, utilizando el SPSS en la versión 20(r). El muestreo contó con 24 personas saludables con un promedio de 22,25 años de edad, todos universitarios, y 21 personas portadoras de trastornos del miembro superior y de la mano, de ambos los sexos. La fiabilidad test-retest para el grupo de sujetos asintomáticos fue de ICC 0,90 (0,78-0,95), en el grupo de los portadores de trastornos de la muñeca y de la mano el ICC encontrado fue de 0,94 (0,87-0,97), ambos considerados excelentes. En los gráficos de Bland y Altman se mostró que aunque la fiabilidad presente niveles excelentes y con bajos valores de error estándar de medida, se encontraron algunos datos divergentes. Los coeficientes de correlación de Pearson fueron altos tanto para el grupo de sujetos asintomáticos (r=0,85) como para el grupo de portadores (r=0,83). Con base en los resultados de la muestra evaluada se propone que la célula de carga puede ser un dispositivo fiable y válido para medir la fuerza de presión palmar isométrica de la mano, y que puede utilizarla futuramente en investigaciones y en la práctica clínica.


ABSTRACT The grip strength is a complex measure influenced by factors such as gender, age, motivation, muscle training, handedness, height, weight, socioeconomic variables, and participation in specific sports or professions. It can be measured by dynamometers or by tension meters such as load cells (strain gauges). Reliability and validity are important psychometric properties, which analyze consistency and applicability of an instruments' measurement. Thus, the aim of this study was to evaluate the test-retest reliability and construct validity of a load cell device in isometric grip force measurements using a sample of asymptomatic subjects and patients with wrist and hand dysfunctions. Standardized methods of the upper limb positioning and randomization of the sample order were used. Statistical analysis of reliability was conducted by the ICC (Intraclass Correlation Coefficient) and the construct validity by Pearson correlation coefficient (r), with p<0.05, 95% CI, using SPSS version 20(r). The sample consisted of 24 healthy volunteers with an average age of 22.25 years old, all college students, and 21 volunteers with upper extremity and hand disorders, from both genders. The test-retest reliability for the asymptomatic group was ICC 0.90 (0.78-0.95) and for the group of patients was 0.94 (0.87-0.97), both considered excellent. The Bland and Altman graphics showed that although the reliability has displayed excellent levels and low standard error values of measurement, some discrepant data were found. Pearson correlation coefficients were high, both for the asymptomatic group (r=0.85), and for the patients group (r=0.83). Conclusion: based on these findings, it is suggested that this load cell is a reliable and valid device for isometric grip strength measurement and its use is suitable for future clinical trials and practice.

18.
Cad. saúde pública ; Cad. Saúde Pública (Online);31(7): 1473-1482, 07/2015. tab
Artigo em Inglês | LILACS | ID: lil-754036

RESUMO

This study evaluates the agreement of nosologic coding of cardiovascular causes of death between a Chilean coder and one in the United States, in a stratified random sample of death certificates of persons aged ≥ 60, issued in 2008 in the Valparaíso and Metropolitan regions, Chile. All causes of death were converted to ICD-10 codes in parallel by both coders. Concordance was analyzed with inter-coder agreement and Cohen’s kappa coefficient by level of specification ICD-10 code for the underlying cause and the total causes of death coding. Inter-coder agreement was 76.4% for all causes of death and 80.6% for the underlying cause (agreement at the four-digit level), with differences by the level of specification of the ICD-10 code, by line of the death certificate, and by number of causes of death per certificate. Cohen's kappa coefficient was 0.76 (95%CI: 0.68-0.84) for the underlying cause and 0.75 (95%CI: 0.74-0.77) for the total causes of death. In conclusion, causes of death coding and inter-coder agreement for cardiovascular diseases in two regions of Chile are comparable to an external benchmark and with reports from other countries.


Este estudo avaliou a confiabilidade na codificação das causas de óbitos cardiovasculares entre um codificador no Chile e outro nos Estados Unidos, em uma amostra aleatória estratificada de declarações de óbito de pessoas ≥ 60 anos, emitidas em 2008 nas regiões de Valparaíso e Metropolitana do Chile. Todas as causas da morte foram convertidas em códigos CID-10 em paralelo por ambos os codificadores. A confiabilidade foi avaliada de acordo com o intercodificador e o coeficiente kappa de Cohen, segundo o nível de especificação do código CID-10 para a codificação de causa básica e para todas as causas de óbito. A concordância intercodificador foi de 76,4% para todas as causas de morte e 80,6% para a causa básica (acordo no nível de quatro dígitos), com diferenças por nível de especificação do código CID-10, linha da declaração de óbito, e por número de causas de morte por declaração de óbito. O coeficiente kappa foi 0,76 (IC95%: 0,68-0,84) para a causa básica e 0,75 (IC95%: 0,74-0,77) para todas as causas de óbito. Em conclusão, a codificação das causas de morte cardiovasculares e acordo intercodificador em duas regiões do Chile são comparáveis a uma referência externa e com os relatórios de outros países.


Este estudio evalúa la concordancia en la codificación de causas de muerte cardiovasculares entre un codificador en Chile y otro en EEUU en una muestra aleatoria estratificada de certificados de defunción de personas ≥ 60 años, emitidos el 2008 en las Regiones de Valparaíso y Metropolitana de Chile. Todas las causas de muerte fueron convertidas a códigos CIE-10 en paralelo por ambas codificadoras. La concordancia se analizó con el acuerdo inter-codificador y el coeficiente kappa de Cohen, según nivel de especificación del código CIE-10 para la codificación de la causa básica y para el total de causas de muerte. El acuerdo inter-codificador fue 76,4% para el total de causas de muerte y 80,6% para la causa básica (acuerdo a nivel de cuatro dígitos), con diferencias según nivel de especificación del código CIE, línea del certificado y número de causas de muerte por certificado. El coeficiente kappa de Cohen fue 0,76 (IC95%: 0,68-0,84) para la causa básica y 0.75 (IC95%: 0.74-0.77) para el total de causas de muerte. En conclusión, la codificación de causas de muerte cardiovasculares y el acuerdo inter-codificador en dos regiones de Chile son comparables a una referencia externa y a informes internacionales.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Codificação Clínica/normas , Atestado de Óbito , Insuficiência Cardíaca/mortalidade , Causas de Morte , Chile/epidemiologia , Codificação Clínica/estatística & dados numéricos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estados Unidos/epidemiologia
19.
Rev. bras. ter. intensiva ; 27(2): 105-112, Apr-Jun/2015. tab, graf
Artigo em Português | LILACS | ID: lil-750771

RESUMO

RESUMO Objetivo: O European Surgical Outcomes Study foi um estudo que descreveu a mortalidade após a cirurgia de pacientes internados. Em uma análise multivariada, foram identificados diversos fatores capazes de prever maus resultados, os quais incluem idade, urgência do procedimento, gravidade e porte, assim como o escore da American Association of Anaesthesia. Este estudo descreveu, com mais detalhes, o relacionamento entre o escore da American Association of Anaesthesia e a mortalidade pós-operatória. Métodos: Os pacientes neste estudo de coorte com duração de sete dias foram inscritos em abril de 2011. Foram incluídos e seguidos, por no máximo 60 dias, pacientes consecutivos com idade de 16 anos ou mais, internados e submetidos à cirurgia não cardíaca e com registro do escore da American Association of Anaesthesia em 498 hospitais, localizados em 28 países europeus. O parâmetro primário foi mortalidade hospitalar. Foi utilizada uma árvore decisória, com base no sistema CHAID (SPSS), para delinear os nós associados à mortalidade. Resultados: O estudo inscreveu um total de 46.539 pacientes. Em função de valores faltantes, foram excluídos 873 pacientes, resultando na análise 45.666. Aumentos no escore da American Association of Anaesthesia se associaram com o acréscimo das taxas de admissão à terapia intensiva e de mortalidade. Apesar do relacionamento progressivo com mortalidade, a discriminação foi fraca, com uma área sob a curva ROC de 0,658 (IC 95% 0,642 - 0,6775). Com o uso das árvores de regressão (CHAID), foram identificadas quatro discretas associações dos nós da American Association of Anaesthesia com mortalidade, estando o escore American Association of Anaesthesia 1 e o escore da American Association of Anaesthesia 2 comprimidos em um mesmo nó. Conclusão: O escore da American Association of Anaesthesia pode ser utilizado para determinar grupos de pacientes cirúrgicos de alto risco, porém os médicos não podem utilizá-lo para ...


ABSTRACT Objective: The European Surgical Outcomes Study described mortality following in-patient surgery. Several factors were identified that were able to predict poor outcomes in a multivariate analysis. These included age, procedure urgency, severity and type and the American Association of Anaesthesia score. This study describes in greater detail the relationship between the American Association of Anaesthesia score and postoperative mortality. Methods: Patients in this 7-day cohort study were enrolled in April 2011. Consecutive patients aged 16 years and older undergoing inpatient non-cardiac surgery with a recorded American Association of Anaesthesia score in 498 hospitals across 28 European nations were included and followed up for a maximum of 60 days. The primary endpoint was in-hospital mortality. Decision tree analysis with the CHAID (SPSS) system was used to delineate nodes associated with mortality. Results: The study enrolled 46,539 patients. Due to missing values, 873 patients were excluded, resulting in the analysis of 45,666 patients. Increasing American Association of Anaesthesia scores were associated with increased admission rates to intensive care and higher mortality rates. Despite a progressive relationship with mortality, discrimination was poor, with an area under the ROC curve of 0.658 (95% CI 0.642 - 0.6775). Using regression trees (CHAID), we identified four discrete American Association of Anaesthesia nodes associated with mortality, with American Association of Anaesthesia 1 and American Association of Anaesthesia 2 compressed into the same node. Conclusion: The American Association of Anaesthesia score can be used to determine higher risk groups of surgical patients, but clinicians cannot use the score to discriminate between grades 1 and 2. Overall, the discriminatory power of the model was less than acceptable for widespread use. .


Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/mortalidade , Nível de Saúde , Mortalidade Hospitalar , Sociedades Médicas , Estados Unidos , Árvores de Decisões , Estudos de Coortes , Seguimentos , Europa (Continente) , Anestesiologia , Pessoa de Meia-Idade
20.
Ciênc. Saúde Colet. (Impr.) ; Ciênc. Saúde Colet. (Impr.);19(10): 4257-4265, nov. 2014. tab
Artigo em Português | LILACS | ID: lil-722747

RESUMO

O objetivo deste artigo é analisar a confiabilidade dos diagnósticos de internações por causas externas do Sistema Único de Saúde (SUS). Os diagnósticos de internação do Sistema de Informações Hospitalares-SUS (SIH-SUS) foram comparados aos do banco pesquisa, construído com informações das autorizações de internação hospitalar (AIH) complementadas por outras fontes. A confiabilidade foi analisada por agrupamentos utilizando concordância bruta e estatística Kappa. A concordância bruta foi de 41,1% em Londrina e 15,8% em Maringá e a melhor confiabilidade foi a moderada para os agrupamentos das lesões autoprovocadas e acidentes de transporte em Londrina (kappa 0,57 e 0,56), ao passo que em Maringá foi a aceitável para as lesões autoprovocadas (kappa 0,28). As baixas concordâncias com padrões diferenciados segundo os agrupamentos de causas e segundo os municípios evidenciam que esforços devem ser empreendidos para melhorar a qualidade e utilização do SIH-SUS para conhecer e intervir nos acidentes e violências no Brasil.


The scope of this article is to analyze the reliability of the diagnoses of hospital admissions for external causes financed by the Brazilian Unified Health System (SUS). The diagnoses for hospital admissions from the Hospital Information System (SIH-SUS) data were compared with those from the research panel created from information culled from authorizations for hospital admission (AIH) complemented with information from other sources. The reliability was analyzed in groups using crude agreement and Kappa statistics. The crude agreement was 41.1% in Londrina and 15.8% in Maringá and the highest reliability was found for groupings for self-inflicted lesions and traffic accidents in Londrina (Kappa 0.57 and 0.56) while in Maringá reliability was acceptable for self-inflicted lesions (Kappa 0.28). The low agreement with differentiated standards according to groupings of causes and according to the municipalities highlight the fact that efforts must be made to improve the quality and use of the SIH-SUS in order to understand and intervene in accidents and violence in Brazil.


Assuntos
Humanos , Diagnóstico , Sistemas de Informação Hospitalar , Admissão do Paciente , Brasil , Cidades , Atenção à Saúde , Reprodutibilidade dos Testes , Saúde da População Urbana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA