Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Braz. J. Pharm. Sci. (Online) ; 59: e23020, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520324

ABSTRACT

Abstract Certolizumab pegol (CZP) is a Fab' fragment of the humanized antibody with anti-TNF-α activity that is indicated as therapy for Crohn's disease and rheumatoid arthritis. Using a BioSep-SEC-S3000 column (300 x 4.6 mm i.d., 5 µm particle size), a size exclusion liquid chromatography (SEC) method was developed. Mobile phase A consisted of 100 mM monobasic sodium phosphate and 200 mM sodium chloride (pH 7.0), while mobile phase B was ethanol (95:5, v/v), and the analysis was performed using a diode array detector (DAD) set to 214 nm and a flow rate of 0.5 ml min-1. In addition, a reversed-phase liquid chromatography (RP-LC) method based on gradient elution was developed on a Zorbax 300 SB C18 column (150 mm x 4.6 mm i.d., 3.5 µm particle size) kept at 80 °C. Mobile phase A was 0.1% (v/v) TFA in ultrapure water, and mobile phase B was a mixture of propanol, acetonitrile, ultrapure water and TFA (70 + 20 + 9.9 + 0.1, v/v) operated at a flow rate of 1.0 ml min-1, and DAD was applied at 214 nm. CZP elution was achieved with retention times of 5.6 min and 9.0 min for SEC and RP-LC, respectively.

2.
Braz. J. Pharm. Sci. (Online) ; 56: e17419, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1089174

ABSTRACT

Verbena litoralis is a plant popularly known as "gervãozinho-do-campo" in Portuguese. It is traditionally used for stomach, liver and gallbladder problems, and as an anti-inflammatory and anthelmintic. The goal of this study was to determine the chemical composition of the crude extract obtained from the aerial parts of V. litoralis by Ultra High Performance Liquid chromatography coupled with Mass Spectrometry in Tandem (UHPLC-MS/MS); assess the anti-inflammatory activity of ethyl acetate fraction and of crude extract; and verify liver, kidney and pancreas damage. In this study, the chemical composition of the extract was identified via UHPLC/MS/MS, assessing the anti-inflammatory activity of the crude extract and the acetate fraction in an induction model of the granulomatous tissue, as well as given liver, kidney and pancreas damage markers. Chlorogenic acid, luteolin, caffeic acid, apigenin, p-coumaric acid, vanillic acid, ferulic acid and quercetin were quantified in the extract. After the seven-day treatment, the granuloma of the animals treated with the plant extract and fraction presented values very close to the positive control (nimesulide). The V. litoralis crude extract and ethyl acetate fraction show anti-inflammatory activity similar to the nimesulide without evidence of liver, kidney and pancreas damage, which attributes the plant's pharmacological action to the flavonoids found.

3.
Braz. J. Pharm. Sci. (Online) ; 55: e18328, 2019. tab, graf
Article in English | LILACS | ID: biblio-1039071

ABSTRACT

Recombinant human interferon beta 1b (rhIFNß-1b) is clinically used to treat multiple sclerosis. A reversed-phase liquid chromatography (RP-LC) method was carried out on a Jupiter C4 column (250 mm × 4.6 mm i.d.). The mobile phase A consisted of 0.1% trifluoroacetic acid (TFA) in water, and the mobile phase B was acetonitrile with 0.1% TFA run at a flow rate of 1.0 mL/min. A size exclusion liquid chromatography (SE-LC) method was carried out on a BioSep-SEC-S 2000 column (300 mm × 7.8 mm i.d.). The mobile phase consisted of 1 mM monobasic potassium phosphate, 8 mM sodium phosphate dibasic and 200 mM sodium chloride buffer pH 7.4, run isocratically at a flow rate of 0.8 mL/min. Retention times were 31.87 and 17.78 min, and calibration curves were linear over the concentration range of 1-200 µg/mL (r2 = 0.9998) and 0.50-200 µg/mL (r2 = 0.9999), respectively, for RP-LC and SE-LC, with detection at 214 nm. Liquid chromatography (LC) methods were validated and employed in conjunction with the in vitro bioassay to assess the content/potency of rhIFNß-1b, contributing to improve the quality control and to ensure the efficacy of the biotherapeutic


Subject(s)
Biological Assay/methods , Humans , Chromatography, Reverse-Phase/methods , Interferon beta-1b/analysis , In Vitro Techniques , Biotechnology/classification , Validation Study
4.
Article in Portuguese | LILACS | ID: lil-672215

ABSTRACT

No presente trabalho, avaliou-se a atividade anti-inflamatória do extrato hidroetanólico das folhas de Morus alba, através do modelo de indução de tecido granulomatoso e analisaram-se os efeitos toxicológicos sobre o fígado pela dosagem de AST e ALT e sobre o rim, pela dosagem de creatinina. O extrato hidroetanólico das folhas de M. alba foi administrado oralmente, três vezes ao dia, durante 6 dias. A nimesulida (5 mg/kg/dia) foi utilizada como controle positivo e o propilenoglicol 20% como controle negativo. Após o tratamento, foi avaliada a formação do granuloma e realizada a dosagem de AST, ALT e creatinina em todos os grupos. Os animais tratados com o extrato de M. alba apresentaram inibição do processo inflamatório de 20,24 ± 6,94%, enquanto que os tratados com controle positivo apresentaram 21,42 ± 6,52%. O extrato hidroetanólico de M. alba demonstrou atividade anti-inflamatória semelhante à nimesulida com ausência de indícios de hepatotoxicidade e nefrotoxicidade.


In this study, the anti-inflammatory activity of a hydroethanolic extract of leaves of Morus alba (white mulberry) was assessed in a model of granulomatous tissue induction and the toxicological effects on the liver were analyzed by assaying AST and ALT, and those on the kidney by determining creatinine. The hydroethanolic leaf extract was administered orally three times a day six days. Nimesulide (5 mg /kg/day) was used as a positive control and 20% propylene glycol as a negative control. After the 6-day treatment, granuloma formation was assessed and the levels of AST, ALT and creatinine assayed in all groups. Animals treated with the extract showed inflammation inhibition of 20.24 ± 6.94%, while those treated with positive control showed 21.42 ± 6.52%. The hydroethanolic extract of M. alba thus exhibited anti-inflammatory activity similar to nimesulide, with an absence of hepatotoxicity or nephrotoxicity.


Subject(s)
Animals , Male , Rats , Kidney , Liver , Morus/toxicity , Rats, Wistar
5.
Article in Portuguese | LILACS | ID: lil-655417

ABSTRACT

O presente trabalho avaliou a atividade antimicrobiana in vitro do extrato hidroetanólico e frações hexânica, clorofórmica, acetato de etila e butanólica das folhas de Morus alba L. A concentração inibitória mínima (CIM) foi determinada frente à Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Aspergillus fumigatus e Prothoteca zophii. As frações que apresentaram melhores respostas para a atividade antimicrobiana foram acetato de etila e clorofórmica com CIM de 256 ?g/mL. Não foi possível detectar atividade antimicrobiana para Aspergillus fumigatus em nenhuma das concentrações testadas. A citotoxidade do extrato hidroetanólico foi avaliada através de culturas de células de ovário de hamster chinês (CHO) e células do tecido conectivo de camundongo (NCTC) clone 929, determinando o índice de citotoxidade (IC50). O IC50 foi de 0,34 mg/mL para as células CHO e 3,24 mg/mL para as células NCTC 929. De modo geral, as frações acetato de etila e clorofórmica das folhas de M. alba L. apresentaram moderada atividade antimicrobiana e o extrato bruto demonstrou ação citotóxica in vitro frente as células CHO e NCTC 929.


This study evaluated the in vitro antimicrobial activity of hydroethanolic extract and hexane, chloroform, ethyl acetate and butanol fractions from Morus alba L. leaves. The minimum inhibitory concentration (MIC) was determined using Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Aspergillus fumigatus and Prothoteca zophii. The fractions that better responded the antimicrobial activity were ethyl acetate and chloroform with CIM of 256 ?g/mL. It was unable to detect antimicrobial activity for Aspergillus fumigatus in the tested concentrations. The cytotoxicity of the hydroethanolic extract was evaluated by cell cultures of chinese hamster ovary (CHO) and connective tissue of mouse clone 929 (NCTC), determining the level of cytotoxicity (IC50). The IC50 obtained was 0.34 mg/mL for CHO and 3.24 mg/ml for NCTC 929 cells. In general, ethyl acetate and chloroform fractions from M. alba L. leaves showed moderate antimicrobial activity and its extract presented in vitro cytotoxicity against CHO and NCTC 929 cells.


Subject(s)
Anti-Infective Agents , Moraceae , Morus
6.
Rev. bras. hematol. hemoter ; 31(5): 326-332, 2009. ilus, tab
Article in English | LILACS | ID: lil-533585

ABSTRACT

Unfractionated heparins are used clinically as anticoagulants. The biological potency of thirteen samples of raw material and pharmaceutical formulations were assessed utilizing the 5th International Standard of heparin using the sheep plasma coagulation inhibition assay, activated partial thromboplastin time, anti-factor Xa assay, and anti-factor IIa assay, resulting in mean potencies of 101.15 percent, 96.15 percent, 98.15 percent and 99.37 percent, respectively. The samples were also evaluated by the protamine neutralization test giving results within the range of 92 - 138 IU/mg. The anti-factor IIa assay was performed showing reproducibility and significant correlation with the pharmacopoeial assays, thus demonstrating it to be a feasible alternative to the sheep plasma coagulation inhibition assay. Moreover, an analysis by nuclear magnetic resonance and capillary electrophoresis showed some peaks attributable to oversulfated chondroitin sulfate. The results show that batch-to-batch variations and the quality of samples contributed to improvements in the quality control of pharmaceutical products and to assure the safe use and clinical efficacy of this biological medicine.


As heparinas não fracionadas são utilizadas clinicamente como anticoagulantes. A potência biológica de 13 amostras de matérias-primas e produtos farmacêuticos foram avaliadas em relação ao 5ª Padrão Internacional de heparina pelos ensaios da inibição da coagulação do plasma ovino, tempo de tromboplastina parcial ativada, anti-fator Xa e anti-fator IIa, que forneceram potências médias de 101,15 por cento, 96,15 por cento, 98,15 por cento e 99,37 por cento, respectivamente. As amostras foram também submetidas ao teste de neutralização pela protamina que apresentou resultados entre 92-138 UI/mg. Demonstrou-se reprodutibilidade e correlação significativa do ensaio do anti-fator IIa com os farmacopeicos, constituindo-se em alternativa ao ensaio da inibição da coagulação do plasma ovino. Além disso, as análises realizadas por ressonância magnética nuclear e eletroforese capilar mostraram picos correspondentesà condroitina supersulfatada. Os resultados mostraram variações lote-a-lote e a qualidade das amostras contribuindo para aprimorar o controle de qualidade dos produtos farmacêuticos e garantir a segurança e eficácia terapêutica desses produtos biológicos.


Subject(s)
Animals , Blood Coagulation , Blood Coagulation Tests , Heparin , Partial Thromboplastin Time , Sheep
7.
Ciênc. rural ; 37(1): 190-194, jan.-fev. 2007. tab
Article in Portuguese | LILACS | ID: lil-440091

ABSTRACT

Realizou-se a avaliação de pirogênios em produtos veterinários de uso parenteral, pelo método da hipertermia em coelhos, calculando-se, para o teste das amostras, doses com concentrações de três a sete vezes superiores à terapêutica. Preconizou-se como resposta positiva o aumento de temperatura de 0,6°C. Utilizou-se também o ensaio do lisado de amebócitos do Limulus (LAL) por geleificação, semiquantitativo, executando o teste de interferentes, validando o procedimento e estabelecendo a máxima diluição válida para a análise de cada produto. Paralelamente, efetuou-se avaliação comparativa de amostras com o método do LAL cromogênico, quantitativo, demonstrando correlação e reprodutibilidade dos resultados. Avaliaram-se vinte e oito produtos de diferentes classes farmacológicas, observando-se que dois não cumpriram as especificações, sendo reprovados. Sugere-se que as especificações estudadas sejam adotadas, contribuindo para aprimorar o controle de contaminantes, garantindo a qualidade e a segurança dos produtos veterinários.


The rabbit pyrogen test was used to evaluate veterinary products, suggesting the temperature rise of 0.6°C as the ending point for the positive results. The test doses were calculated based on the therapeutic dose increased from three to seven times. The semi-quantitative Limulus amoebocyte lysate (LAL) gel clot test was performed and compared to the LAL spectrophotometric chromogenic, quantitative assay. The comparative evaluation of the samples showed correlation and reproducibility of the results. The interference test was carried out, the procedure validated and the maximum valid dilution established for the analysis of the products without Pharmacopoeial specifications. Two of the twenty-eight products of different pharmacological groups evaluated didn't meet the requirements and were reproved. The specifications investigated are suggested to be used for the purity evaluation of the veterinary parenteral products, as a contribution to assure the quality and safety of the products.

8.
Rev. bras. hematol. hemoter ; 28(1): 28-32, jan.-mar. 2006. ilus, graf
Article in English, Portuguese | LILACS | ID: lil-434895

ABSTRACT

The effects of the cyclooxygenase (COX)-2 selective inhibitor, valdecoxib, on blood coagulation parameters were evaluated, along with aspirin in male Wistar rats. Groups of animals were administered a daily oral dose of 10 mg/kg rat of valdecoxib, 100 mg/kg rat of aspirin and the vehicle alone during 4 weeks. Blood samples were collected at the end of 1, 2, 3 and 4 weeks of administration period and the plasma concentrations of valdecoxib were determined by RP-HPLC giving mean values of 101.1, 113.5, 164.0 and 184.6 ng/mL, respectively. The same plasma samples were used for the analysis of hematological parameters and the results compared to the controls. Valdecoxib induced significant activated partial thromboplastin time reduction (18 percent) after 2 weeks and prothrombin time reduction (12.2 percent) after 3 weeks (P<0.05). There were no significant changes in the platelet count and fibrinogen levels. The anti-factor Xa and anti-factor IIa activities showed slight reductions, but only significant for the anti-factor Xa on the 3rd week (6.7 percent). The results showed that valdecoxib at the dose tested with the plasmatic concentrations induced some changes in the hemostatic function of rats, which can be helpful to understand the side effects and the safe use of the drug.


Avaliaram-se os efeitos do valdecoxibe, um inibidor seletivo da cicloxigenase-2 (COX-2), sobre os parâ­metros sangüíneos da coagulação em ratos Wistar utilizando-se paralelamente a aspirina. Os animais foram divididos em grupos e submetidos à administração oral diária de 10 mg/kg animal para o valdecoxib, 100 mg/kg animal para a aspirina e veículo para o grupo controle, durante quatro semanas. A coleta do sangue foi efetuada após uma, duas, três e quatro semanas, e as concentrações plasmáticas do valdecoxibe determinadas por cromatografia líquida, obtendo-se valores médios de 101,1 - 113,5 - 164 e 184,6 ng/ml, respectivamente. As amostras de plasma foram também usadas para as análises hematológicas e os resultados comparados aos dos controles. O valde­coxibe apresentou redução significativa no TTPA (18 por cento) após duas semanas, e redução do TP (12,2 por cento) após três semanas (P<0.05). Os efeitos observados na contagem de pla­quetas e nos níveis plasmáticos de fibrinogênio não foram significativos. As atividades anti-fator Xa e anti-fator IIa apresentaram redução, porém os resultados foram significativos somente para o anti-fator Xa na terceira semana (6,7 por cento). Os resultados experimentais com as concentrações plasmáticas alcan­çadas demonstram que o valdecoxibe pode induzir alterações nos parâ­metros hematológicos dos ratos. Esses dados poderão contribuir para a melhor compreensão dos efeitos colaterais e uso do fármaco com segurança.


Subject(s)
Prostaglandin-Endoperoxide Synthases , Partial Thromboplastin Time , Platelet Count , Prothrombin Time , Blood Coagulation , Fibrinogen , Hemostatics , Aspirin , Chromatography, Liquid , Rats, Wistar , Dosage , Reference Standards
9.
Braz. j. microbiol ; 35(1/2): 48-53, Jan.-Jun. 2004. tab, graf
Article in English | LILACS | ID: lil-388796

ABSTRACT

Realizou-se a comparação de metodologia para avaliação de pirogênios em produtos farmacêuticos. Otimizou-se o teste da hipertermia em coelhos elaborando a curva dose-resposta com o 2º Padrão Internacional de endotoxinas bacterianas, com base na qual determinou-se a concentração de 13,81 UE/mL por kg de peso corporal, necessária para produzir aumento de temperatura de 0,5ºC. Observou-se que o limite de 0,5ºC forneceu resultados comparáveis com as doses pirogênicas para o homem. Padronizou-se o teste do lisado de amebócitos do Limulus (LAL) com determinação do ponto final cromogênico e por geleificação, que foram utilizados para a avaliação de produtos farmacêuticos obtendo-se resultados concordantes. Avaliaram-se as respostas de reagentes LAL reativos e não-reativos a b-glicanos, observando diferenças que poderiam reprovar amostras com base em resultados falso-positivos. Executou-se o teste de interferências, validou-se o procedimento e estabeleceu-se a máxima diluição válida para produtos farmacêuticos sem especificações farmacopéicas. Os resultados enfatizam a importância e as limitações dos ensaios preconizados para avaliação da pureza e controle da qualidade de produtos farmacêuticos parenterais, contribuindo para aprimorar as metodologias existentes no contexto da redução e substituição dos modelos animais.


Subject(s)
Chemical Compounds , Endotoxins , Fever , Pyrogens/isolation & purification , Rabbits , Methods
10.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469518

ABSTRACT

A comparison of methodologies for detection of pyrogens in pharmaceutical products was performed. The rabbit pyrogen test was optimized and the dose-response curve was obtained for the 2nd International Standard for bacterial endotoxins, establishing 13.81 EU/mL/kg as the concentration of endotoxin necessary to induce a temperature rise of 0.5ºC. The 0.5ºC cut-off was shown to give results that were more compatible with the pyrogenic doses for humans. The Limulus amoebocyte lysate test (LAL) was standardized with gel-clot and chromogenic endpoints, and used for the comparative evaluation of pharmaceutical products showing good agreement. The use of beta-glucan-reactive and non-reactive LAL reagents identified some products with false-positive results. The interference test was carried out and the specifications validated for some new products as the maximum valid dilution. The results emphasized the importance and limitations of the assays recommended for the evaluation of purity and quality control of parenteral medicinal products, improving the existing methodologies in the context of reduction and replacement in the use of animal models.


Realizou-se a comparação de metodologia para avaliação de pirogênios em produtos farmacêuticos. Otimizou-se o teste da hipertermia em coelhos elaborando a curva dose-resposta com o 2º Padrão Internacional de endotoxinas bacterianas, com base na qual determinou-se a concentração de 13,81 UE/mL por kg de peso corporal, necessária para produzir aumento de temperatura de 0,5ºC. Observou-se que o limite de 0,5ºC forneceu resultados comparáveis com as doses pirogênicas para o homem. Padronizou-se o teste do lisado de amebócitos do Limulus (LAL) com determinação do ponto final cromogênico e por geleificação, que foram utilizados para a avaliação de produtos farmacêuticos obtendo-se resultados concordantes. Avaliaram-se as respostas de reagentes LAL reativos e não-reativos a beta-glicanos, observando diferenças que poderiam reprovar amostras com base em resultados falso-positivos. Executou-se o teste de interferências, validou-se o procedimento e estabeleceu-se a máxima diluição válida para produtos farmacêuticos sem especificações farmacopéicas. Os resultados enfatizam a importância e as limitações dos ensaios preconizados para avaliação da pureza e controle da qualidade de produtos farmacêuticos parenterais, contribuindo para aprimorar as metodologias existentes no contexto da redução e substituição dos modelos animais.

11.
Rev. bras. hematol. hemoter ; 26(2): 104-108, 2004. ilus, tab
Article in English | LILACS | ID: lil-394866

ABSTRACT

Realizou-se a identificação do fator estimulador da colônia de granulócitos humanos recombinante em produtos farmacêuticos por eletroforese em gel de poliacrilamida não redutora e imunodetecção com anticorpos específicos, que apresentaram banda única na região de, aproximadamente, 19 kDa. A avaliação de potência baseada na contagem do número de neutrófilos em camundongos com neutropenia forneceu valores entre 88,4 ù 122,4 % em relação à potência declarada. A precisão expressa pela ponderação, calculada nos ensaios independentes, forneceu valores entre 141 e 432. As amostras lote-a-lote cumpriram os requisitos dos testes de toxicidade e endotoxinas bacterianas. Os resultados dos ensaios biológicos e imunológicos demonstram a qualidade dos produtos farmacêuticos em uso clínico, e as especificações sugeridas contribuem para assegurar a inocuidade e eficácia terapêutica dos produtos biológicos.


Subject(s)
Humans , Biological Assay , Filgrastim/pharmacology , Granulocyte Colony-Stimulating Factor , Neutropenia
12.
Rev. bras. hematol. hemoter ; 25(2): 103-110, abr.-jun. 2003. tab
Article in Portuguese | LILACS | ID: lil-351827

ABSTRACT

Realizou-se a avaliação biológica de potência de heparinas convencionais contra o 5º Padrão Internacional de heparina suína pelos ensaios preconizados da inibição da coagulação do plasma ovino (ICPO), tempo de tromboplastina parcial ativada (TTPA) e anti-fator Xa. Correlacionaram-se os resultados, demonstrando que o ICPO fornece potências em média 10,72 por cento, significativamente superiores aos outros procedimentos. Analisou-se a influência de diferentes lotes de plasma sobre o resultado do ensaio do ICPO observando-se variação de até 7,32 por cento. Como alternativa, padronizou-se o ensaio do anti-fator IIa e efetuou-se a determinação de potência das amostras obtendo-se valores reprodutíveis, comparáveis ao método do anti-fator Xa, que demonstram a viabilidade da inclusão como ensaio harmonizado para o controle da qualidade. Os resultados de potência, fornecidos lote a lote, em geral, cumprem as especificações farmacopéicas e demonstram a qualidade que garante a segurança e eficácia clínica dos medicamentos


Subject(s)
Animals , Cattle , Anticoagulants , Heparin , Partial Thromboplastin Time
13.
Arq. bras. endocrinol. metab ; 47(2): 183-189, abr. 2003. ilus, tab
Article in Portuguese | LILACS | ID: lil-337107

ABSTRACT

Realizou-se a identificaçäo de eritropoietina humana recombinante em produtos farmacêuticos comerciais por eletroforese em gel de poliacrilamida e detecçäo com anticorpos específicos, demonstrando-se típica banda larga, semelhante ao padräo de rhEPO da Farmacopéia Européia. Igualmente por focalizaçäo isoelétrica e imunodetecçäo, observaram-se 5-6 isoformas características de acordo com o laboratório produtor. A avaliaçäo de potência efetuada através de ensaio biológico em camundongos normocitêmicos forneceu valores entre 67,6 por cento e 119,4 por cento em relaçäo à declarada. A precisäo dos ensaios combinados, calculada pela ponderaçäo, variou de 200 a 389. Os testes de endotoxinas bacterianas, toxicidade e pH apresentaram valores variáveis conforme o lote. Concluiu-se destacando a importância dos testes e ensaios de controle para assegurar a qualidade lote a lote e garantir a eficácia terapêutica dos produtos farmacêuticos


Subject(s)
Animals , Female , Mice , Erythropoietin , Pharmaceutical Preparations , Biological Assay , Sodium Dodecyl Sulfate , Electrophoresis, Polyacrylamide Gel , Toxicity Tests
14.
São Paulo; s.n; 1998. 127 p. ilus, tab.
Thesis in Portuguese | LILACS | ID: lil-272130

ABSTRACT

Padronizou-se metodologia de cromatografia líquida de alta eficiência em fase reversa (RP-HPLC) isocrática para determinação de hormônio de crescimento humano recombinante (rec-hGH) em extratos periplásmicos de E. coli. O procedimento possibilitou uma rápida análise inicial da qualidade e quantidade de hGH secretado no espaço periplásmico, imediatamente após, ou mesmo durante a fermentação. Considerando que a RP-HPLC não identifica isômeros de massa, estes foram determinados através da análise paralela dos extratos periplásmicos por cromatografia líquida de alta eficiência por exclusão molecular (HPSEC) e radioimunoensaio (RIE) das frações eluídas. O método permitiu obter em 24 h, do início do processo de fermentação, uma avaliação da atividade, identidade, rendimento e contaminantes relacionados ao hGH. Entre esses incluem-se os sulfóxidos e desamidados, dímero e formas de alta massa molecular. As metodologias padronizadas foram empregadas em diferentes etapas da produção de rec-hGH. O processo de fermentação de E. coli transformada foi otimizado, escolhendo-se o melhor tempo de ativação, que propiciou maior nível de secreção de hGH e a menor quantidade de formas alternadas. Analisou-se uma das primeiras fases do processo de purificação, confirmando-se a ausência de perdas significativas em formas poliméricas. A liofilização foi aprimorada, possibilitando a preparação e estudo de diferentes padrões. Todos esses estudos acrescentaram importantes conhecimentos para o controle de qualidade do produto farmacêutico injetável. que foi realizado de acordo com as recomendações das Farmacopéias Européia e Brasileira


Subject(s)
Chromatography, High Pressure Liquid , DNA, Recombinant , Growth Hormone
15.
Mem. Inst. Butantan ; 54(1): 21-30, 1992. tab
Article in Portuguese | LILACS, SES-SP | ID: lil-125824

ABSTRACT

The determination of the LD50 of bothropic reference venom and the evaluation of the respective antivenin potency were standardized by intraperitoneal inoculation in mice. The computer program was developed for the calculations of the LD50 and the potency(ED50) by probit analysis. The final results were consistent and reproducibles. The weight obtained in independent assays was between 374 and 1762. The precision index was < 0,10


Subject(s)
Poisons , Antivenins
16.
Arq. bras. endocrinol. metab ; 31(1): 10-2, 14, mar. 1987. ilus, tab
Article in Portuguese | LILACS | ID: lil-41408

ABSTRACT

O bioensaio de hormônio de crescimento humano por incremento de peso corpóreo de ratos hipofisectomizados tem sido estudado com enfoque especial na economia de tempo e material, além de melhorar ou ao menos manter a qualidade dos parâmetros estatísticos do ensaio fatorial 2x2 clássico, que usa doses de 20 e 100microng/rato/dia. A determinaçäo da atividade biológica e dos parâmetros estatísticos relativos foi obtida através de um programa de computaçäo BASSY, em linguagem FORTRAN IV, descrito para a análise de ensaio fatorial 2x2. Com uma sensibilidade calculada da ordem de 2migrong/rato/dia, o ensaio pode ainda ser realizado em condiçöes de maior economia usando-se apenas um total de 0,6mg de hGH, com índice de precisäo inferior a 0,3. O presente estudo também mostra a excelente estabilidade das preparaçöes padräo (WHO) e Ipen ampolizadas e a precisäo interensaio relativamente alta deste bioensaio in vivo: CV = 8,7 e 18,9% respectivamente, usando-se o mesmo (n = 3) e diferentes (n = 6) esquemas de ensaio em um período superior a um ano


Subject(s)
Rats , Animals , Body Weight/drug effects , Growth Hormone/metabolism , Hypophysectomy , Computers , Factor Analysis, Statistical
SELECTION OF CITATIONS
SEARCH DETAIL