Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Ciênc. rural (Online) ; 50(3): e20190790, 2020. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1089565

ABSTRACT

ABSTRACT: The objective of this study was to evaluate the effect of the initial microbial load, temperature and contact time on the biofilm formation of Alicyclobacillus acidoterrestris on stainless steel and natural food-grade rubber using orange juice as culture medium. The low initial load of A. acidoterrestris (2 log CFU/mL) led to biofilm formation on the stainless steel surface after 48 h of contact at 28 ºC and after 24 h at 45 ºC, and on natural food-grade rubber surface after 48 h of contact at both temperatures. The high initial microbial load (5 log CFU/mL) led to biofilm formation on stainless steel after 4 h of contact at 28 °C and 45 °C, while biofilm was formed on natural food-grade rubber after 8 h of contact at 28 °C and 4 h at 45 °C. The microbial load also affected the presence of spores in biofilm, which was observed on both surfaces only at high initial loads of A. acidoterrestris.


RESUMO: O objetivo deste estudo foi avaliar o efeito da carga microbiana inicial, temperatura e tempo de contato na formação de biofilme de Alicyclobacillus acidoterrestris em aço inoxidável e borracha natural de qualidade alimentar utilizando suco de laranja como meio de cultura. A baixa carga inicial de A. acidoterrestris (2 log UFC/mL) levou à formação de biofilme na superfície do aço inoxidável após 48 h de contato a 28 ºC e após 24 h a 45 ºC, e na superfície natural de borracha de qualidade alimentar após 48 h de contato nas duas temperaturas. A alta carga microbiana inicial (5 log UFC/mL) levou à formação de biofilme em aço inoxidável após 4 h de contato a 28 °C e 45 °C, enquanto o biofilme foi formado em borracha natural de qualidade alimentar após 8 h de contato a 28 °C e 4 h a 45 °C. A carga microbiana também afetou a presença de esporos no biofilme, o que foi observado em ambas as superfícies apenas com altas cargas iniciais de A. acidoterrestris.

2.
Hig. aliment ; 33(288/289): 2390-2395, abr.-maio 2019. tab, ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482226

ABSTRACT

Superfícies de aço inoxidável com especificações determinadas pela American Society for Testing and Materials (ASTM) são usadas em testes in vitro para simular a formação e a remoção de biofilmes. Muitas vezes estas superfícies são reutilizadas nos ensaios de formação de biofilmes. O objetivo deste trabalho foi avaliar se cupons de aço inoxidável anteriormente utilizados para formação de biofilmes multiespécies podem ser reutilizados em novos ensaios. Assim, cupons submetidos a diferentes procedimentos de higienização foram analisados por microscopia eletrônica de varredura (MEV) e perfilometria . A reutilização das superfícies em novos experimentos deve ser realizada com cautela, aplicando procedimentos que removam as células bacterianas e a substância polimérica extracelular (EPS) aderidas na superfície. Além disso, observações da superfície (topografia e rugosidade) devem ser avaliadas, comprovando as especificações da ASTM.


Subject(s)
Stainless Steel/analysis , Biofilms , Microscopy, Electron, Scanning/methods , Recycling
3.
Hig. aliment ; 33(288/289): 2529-2533, abr.-maio 2019. tab, ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482254

ABSTRACT

O objetivo deste trabalho foi verificar a influência do tempo e da temperatura na formação de biofilmes de P. fluorescens e P. aeruginosa em superfície de aço inoxidável através de um delineamento composto central rotacional (DCCR). Os biofilmes foram avaliados nas temperaturas de 7; 13; 27; 41 e 47 °C e nos tempos de contato de 0; 1,2; 4; 6,8 e 8 dias. As superfícies de resposta mostraram que P. fluorescens foi capaz de formar biofilme entre 0,9 e 8 dias em temperaturas entre 9,8 e 47 °C. P. aeruginosa foi capaz de formar biofilme entre0,7 a 8 dias e entre 11 e 47 °C. É importante destacar que estas condições são frequentemente encontradas durante todo o processamento de queijo Minas frescal, comprometendo a segurança do alimento.


Subject(s)
Biofilms/growth & development , Dairying , Food Microbiology , Pseudomonas/isolation & purification , Pseudomonas/pathogenicity , Cheese/microbiology
4.
Dental press j. orthod. (Impr.) ; 24(1): 68-73, Jan.-Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-989682

ABSTRACT

ABSTRACT Introduction: The heat treatment of stainless steel wires is a routine clinical procedure adopted by many dentists in order to relieve the stress caused after performing bends in the archwire. Objective: This study aimed to evaluate the influence of heat treatment of stainless steel archwires with a rectangular section of 0.016 x 0.022'-in. Methods: For analysis of the dimensional stability, the anterior and posterior dimensions of forty 0.016 x 0.022-in stainless steel orthodontic archwires without heat treatment and 30 days after heat treatment were evaluated. For analysis of the mechanical properties, 12 stainless steel wire segments with the same rectangular section without heat treatment and 30 days after heat treatment were tested through tensile strength and strain tests. To evaluate if there were differences between the anterior and posterior dimensions, the results were analyzed by the Student's t-test. To compare the tensile strength and strain between the groups, the ANOVA test was used. The level of significance adopted was 95% (p< 0.05). Results: The heat treatment did not stop the expansion of archwires 30 days after their preparation, and there was no statistical difference in the tensile strength and strain tests with and without heat treatment. Conclusion: From the findings of this study, it can be conclude that the mechanical behavior of heat-treated stainless steel archwires is similar to that of archwires not subjected to heat treatment.


RESUMO Introdução: o tratamento térmico de fios de aço inoxidável é um procedimento clínico rotineiro adotado por muitos cirurgiões-dentistas para aliviar o estresse causado após a confecção de dobras no fio. O presente estudo avaliou a influência do tratamento térmico em fios de aço inoxidável com secção retangular de 0,016'' x 0,022''. Métodos: para análise da estabilidade dimensional, foram avaliadas as dimensões anteriores e posteriores de 40 arcos ortodônticos de aço inoxidável de 0,016'' x 0,022'' sem tratamento térmico e 30 dias após o tratamento térmico. Para análise das propriedades mecânicas, 12 segmentos de fio de aço inoxidável com a mesma secção retangular sem tratamento térmico e 30 dias após o tratamento térmico foram analisadas por testes de resistência à tração e tensão. Para verificar se houve diferenças entre as dimensões anteriores e posteriores, os resultados foram analisados pelo teste t de Student. Para comparar a resistência à tração e tensão entre os grupos, foi utilizado o teste ANOVA. O nível de significância adotado foi 95% (p< 0,05). Resultados: o tratamento térmico não interrompeu a expansão dos fios 30 dias após seu preparo, e não houve diferença estatística nos testes de resistência à tração e tensão com e sem o tratamento térmico. Conclusão: pelos achados desse estudo, conclui-se que o comportamento mecânico de fios submetidos a tratamento térmico é semelhante ao de fios de aço não submetidos ao tratamento térmico.


Subject(s)
Orthodontic Wires , Orthodontic Brackets , Stainless Steel , Surface Properties , Tensile Strength , Materials Testing , Dental Alloys , Hot Temperature
5.
Ciênc. rural (Online) ; 47(10): e20170011, 2017. tab, graf
Article in English | LILACS | ID: biblio-1044871

ABSTRACT

ABSTRACT: The consumption of fish by the Brazilian population is increasing. However, fish and seafood are highly perishable and can be contaminated with several microorganisms. In addition, the possibility of biofilm formation is a greater cause for concern. In this study, biofilm formation was evaluated in single- and multispecies cultures at 25°C for incubation periods of 0, 4, 8, 24, and 48h in stainless steel coupons (size, 1.0×1.0cm) immersed in tryptic soy broth. The characteristics of the formed biofilms after sanitizing by immersing the coupons in 200ppm sodium hypochlorite solution for 10min were also evaluated under the same experimental conditions but with some modifications. Biofilm structure was evaluated using scanning electron microscopy. Analysis of single-species biofilms indicated that all bacterial strains formed biofilms at different intervals without any statistically significant difference. However, comparison of the growth of single- and multispecies cultures indicated a significantly higher biofilm formation by the pure cultures. In multispecies biofilms, compared with the other microorganisms, growth of Salmonella spp. was significantly lower for all tested incubation periods; whereas, of Staphylococcus aureus was significantly higher than that of E. coli until 8h of incubation; the differences in growth were not significantly different after this incubation period. Sanitizing with sodium hypochlorite was effective because no cell growth was observed in the coupons that were treated with 200ppm sodium hypochlorite for 10min. This study demonstrated the ability of isolated microorganisms to form biofilms, reinforcing the need for food handling establishments to adopt good manufacturing practices, developing adequate protocols for cleaning and disinfecting surfaces and equipment used in food production, maintaining and replacing equipment when necessary.


RESUMO: A população brasileira tem apresentado um elevado consumo de peixes, no entanto pescados são alimentos altamente perecíveis e podem ser contaminados por uma diversidade de microrganismos. A situação ainda é mais alarmante quando se trata da formação de biofilmes. Para verificação da formação de biofilme, as cepas foram testadas dentro de cultivos mono e multi-espécies a 25°C durante o tempo total de 48h, onde as análises foram realizadas no tempo 0 e nos intervalos de 4, 8, 24 e 48h em cupom de aço inoxidável medindo 1,0x1,0cm, imersos em caldo TSB (Tryptic Soy Broth).O comportamento dos biofilmes formados, diante da sanitização por imersão dos cupons em solução de hipoclorito de sódio a 200ppm por 10 minutos, também foi avaliado, nas mesmas condições citadas acima, com algumas particularidades. A avaliação estrutural foi procedida por microscopia de varredura eletrônica (MEV). Nos resultados de biofilmes mono-espécie, foi verificado que todas as cepas foram capazes de formar biofilme, nos diferentes tempos, sem diferenças estatisticamente significativas. Entretanto, comparando-se o crescimento de culturas mono e múltiplas espécies observou-se formação de biofilme, estatisticamente maior, entre as culturas puras. Nas culturas multi-espécies, Salmonella spp. apresentou crescimento, estatisticamente menor, em todos os tempos, entre os microrganismos testados, enquanto S. aureus apresentou maior crescimento que E. coli até 8 horas de incubação, deste tempo em diante a diferença não foi significativa. Quanto ao comportamento frente sanitização com hipoclorito, o sanitizante foi eficaz, uma vez que não foi observado crescimento celular nas análises dos cupons tratados com a solução de hipoclorito a 200ppm por 10 minutos. Este estudo demonstrou a capacidade dos microrganismos isolados em formar biofilmes, reforçando, a importância dos estabelecimentos manipuladores de alimentos investirem em treinamento de Boas Práticas de Fabricação, desenvolvimento de protocolos adequados de limpeza e desinfecção de áreas e equipamentos envolvidos na produção de alimentos e manutenção e troca desses sempre que se fizer necessário.

6.
Rev. Inst. Adolfo Lutz (Online) ; 74(2): 134-139, abr.-jun. 2015. graf
Article in Portuguese | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-786658

ABSTRACT

Neste estudo as cepas de Escherichia coli produtora de toxina Shiga (STEC) O153:H25, O113:H21 e O111:H8, isoladas de rebanhos do país, foram avaliadas quanto à capacidade de formar biofilmes em superfície de aço inoxidável utilizada na indústria de alimentos, bem como a eficácia de diferentes concentrações de hipoclorito de sódio na inativação desses biofilmes. A capacidade de formação de biofilme foi detectada em todas as cepas de E. coli produtoras de toxina Shiga. Na avaliação da eficáciado sanitizante hipoclorito de sódio, nas concentrações de 100 mg.L-1 e 200 mg.L-1, observou-se a redução a <1 log UFC/cm2 em todas as cepas e nos tempos avaliados. Estes dados reforçam aimportância do correto procedimento de higienização, uma vez que biofilmes podem tornar-se importantes fontes de contaminação no ambiente de produção de alimentos.


This study aimed at evaluating the biofilm formation of Shiga toxin-producing Escherichia coli O153:H25, O113:H21 and O111:H8 (STEC non-O157), isolated from Brazilian cattle, on the stainless steel surface, and also the efficacy of different s concentrations of sodium hypochlorite for inactivating these biofilms. The ability to form biofilm was demonstrated in all of Shiga toxin-producing E. coli strains. In assessing the effectiveness of sodium hypochlorite sanitizer, a reduction to <1 log CFU/cm2 was observed in all of the evaluated strains and times. These data strengthen the relevance of the correct cleaning procedure, considering that biofilms formations might be an important source of food contamination.


Subject(s)
Stainless Steel , Biofilms , Escherichia coli , Shiga-Toxigenic Escherichia coli , Serogroup , Shiga Toxin
7.
Arq. bras. med. vet. zootec ; 67(2): 642-646, Mar-Apr/2015. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1100011

ABSTRACT

Este estudo avaliou a capacidade de Salmonella enterica subsp. enterica isolada de produtos cárneos formar biofilme e testou sua resistência a diferentes sanitizantes. Vinte cepas foram avaliadas quanto à capacidade de formar biofilme em placas de microtitulação. As cepas formadoras de biofilme foram testadas em superfícies de polietileno de alta densidade, aço inoxidável e vidro e tiveram a sensibilidade ao hipoclorito de sódio e ao iodo avaliada. Duas cepas de Salmonella Enteritidis isoladas de produtos de frango apresentaram capacidade de formar biofilme nas superfícies testadas. Essas cepas alcançaram maiores populações nas superfícies do que aquelas não formadoras de biofilme, e foram mais difíceis de remover ou reduzir. Devido à ação sanitizante ser menos eficiente sobre bactérias formadoras de biofilme, esses micro-organismos podem persistir no biofilme formado sobre as superfícies de equipamentos e utensílios e ocasionalmente contaminar os alimentos antes da sua expedição, aumentando dessa forma o risco de ocorrência de doenças transmitidas por alimentos.(AU)


Subject(s)
Stainless Steel , Biofilms , Salmonella enterica , Polyethylene , Drug Resistance, Bacterial , Glass , Sodium Hypochlorite/administration & dosage , Iodine/administration & dosage , Meat Products/microbiology
8.
Belo Horizonte; s.n; 2015. 118 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-790344

ABSTRACT

As propriedades mecânicas, especialmente a resistência dos instrumentos endodônticos de NiTi são influênciadas pelas suas características geométricas, físicas e químicas, somadas ainda à influência da anatomia dos canais radiculares. A exploração e negociação do canal radicular seguido de dilatação prévia ao processo de formatação (Glide Path) reduz consideravelmente as chances de fratura dos instrumentos. Essa manobra elimina as interferências em toda a extensão do canal, possibilitando aos instrumentos seguintes agirem livremente na formação e limpeza minimizando assim, a sobrecarga sobre o mesmo. O objetivo desse trabalho foi avaliar a resitência torcional após uso clínico múltiplo dos instrumentos de Niti PathFile e Scout RaCe e a influência de três diferentes sequências de glide path (K-File, PathFile e Scout RaCe) no comportamento em torção dos instrumentos de formatação MtWo...


The mechanical properties, mainly the resistance of endodontic instruments are affected by factors such as diameter, design, chemical composition, physical properties and canal anatomy. Instrument failure can be controlled by creating a manual or mechanical glide path. The aim of this study was to evaluate the torsional resistance of PathFile and Scout RaCe NiTi rotary instruments with the purpose of "glide path” after multiple clinical use and the influence of three different preflaring (K-File, PathFile and Scout RaCe) on the torsional resistance of shaping Mtwo files after multiple clinical use. The mechanical behavior was evaluated by torsion tests, in accordance with specification ISO 3630-1. All instruments showed geometric features within the tolerance limits and no significant difference concerned about the torsional resistance. Despite of one subtle increase in torsional resistance is noted, it is suggested as an effect of simultaneous sterilization methods or by the work hardening of the NiTi alloy. The present study highlights the importance of preparing the glide path before introducing the shaping files and concludes if sterilization does not render rotary NiTi endodontic instruments stronger, it does not result in deleterious effects that could reducetheir mechanical resistance.


Subject(s)
Dental Instruments , Materials Science/analysis , Stainless Steel , Root Canal Therapy/instrumentation , Infection Control, Dental , Nickel/therapeutic use , Torque , Titanium/therapeutic use
9.
Ortho Sci., Orthod. sci. pract ; 6(23): 279-284, 2013. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-707581

ABSTRACT

Avaliou-se a proporção carga/deflexão da alça ortodôntica em forma de “T” confeccionada com fio retangular de secção transversal 0,019” x 0,025” de ligas de aço inoxidável e beta-titânio de diferentes marcas comerciais. Foram confeccionadas 20 alças para fechamento de espaço provenientes de quatro grupos experimentais de acordo com a liga do fio ortodôntico e com a marca comercial utilizada na confecção da alça: G1 - aço inoxidável da marca comercial Morelli®; G2 - aço inoxidável da marca Ortho Organizers®; G3 - beta-titânio da Ormco™ e G4 - beta-titânio da Ortho Organizers®. As alças foram submetidas ao ensaio mecânico no qual as deflexões de 1,0 mm; 1,5 mm; 2,0 mm; 2,5 mm e 3,0 mm foram procedidas. A carga horizontal liberada pelas alças de beta-titânio, frente às diversas deflexões, foi menor em relação às alças de aço inoxidável com diferença estatisticamente significante (p<0,05). O comportamento dos fios de aço inoxidável Morelli® e Ortho Organizers® foi semelhante nas deflexões de 1,5 mm e 2,5 mm; nas demais ativações o fio da Morelli® conferiu menor proporção carga/deflexão à mola. Os fios de beta-titânio apresentaram resultados semelhantes nas ativações de 1,0 mm, 1,5 mm e 2,0 mm; nas demais ativações o fio da Ormco™ proporcionou menor valor de carga/deflexão do que o fio da Ortho Organizers®. Para a configuração de mola utilizada neste experimento a utilização de fios de beta-titânio confere menor proporção carga/deflexão e proporciona a liberação de força mais leve e constante em comparação aos fios de aço inoxidável.


It was assessed the load-deflection rate of beta-titanium and stainless steel T-loops constructed from 0.019”x0.025” orthodontic archwires of different manufactures. Twenty retraction loop springs were allocated into 4 experimental groups according to the trademark and alloy of the wire used: G1 - stainless steel from Morelli®; G2 - stainless steel from Ortho Organizers®; G3 - beta-titanium from Ormco™; G4 - beta-titanium from Ortho Organizers®. The specimens were submitted to the mechanical test in which the 1.0 mm; 1.5 mm; 2.0 mm; 2.5 mm; and 3.0 mm deflections proceeded. The horizontal load of beta-titanium T-loops was lower than the stainless steel for all deflections evaluated; with statistical significant difference (p<0.05). Tthe stainless steel groups (G1 and G2) showed similar behavior within the 1.5 mm and 2.5 mm deflections and the Morelli® wire (G1) lead the lower horizontal load within the other deflections. The beta-titanium alloy springs showed similar load values within the 1.0 mm, 1.5 mm, and 2.0 mm deflections and the Ormco™ T-loop presented lower load values compared to the Ortho Organizers® within the 2.5 mm and 3.0 mm deflections. For the T-loop sprig configuration the beta-titanium wire leads to lower load-deflection rate and leaches more constant and lower forces than the stainless steel wire.


Subject(s)
Orthodontic Wires , Orthodontics, Corrective , Stainless Steel , Titanium
10.
Article in Portuguese | LILACS | ID: lil-667061

ABSTRACT

A maioria dos casos de fraturas ósseas é utilizada nas cirurgias, implantes ortopédicos de osteossíntese (placa-parafuso e parafusos) e a infecção associada ao implante está relacionada com crescimento de microrganismos em biofilme. O objetivo deste estudo foi identificar os microrganismos recuperados de implantes de osteossíntese usados para fixação de fratura óssea, avaliar a viabilidade celular, a capacidade de aderência dos estafilococos e, determinar o perfil de sensibilidade/resistência aos antimicrobianos. Após a remoção cirúrgica, os conjuntos metálicos de aço inoxidável austenítico ASTM F138/F139 ou ISO NBR 5832-1/9 foram enviados ao Laboratório de Microbiologia Clínica, lavados em solução tampão e submetidos ao banho ultrassônico em 40±2 kHz por 5 minutos. O fluido sonicado foi semeado em meios de cultura e a viabilidade celular foi avaliada por meio de marcador fluorescente. A produção de polissacarídeo extracelular por Staphylococcus spp. foi averiguada por meio do teste de aderência em placa de poliestireno. O perfil de sensibilidade/resistência foi determinado por meio de técnica do disco difusão. As bactérias mais isoladas incluíram Staphylococcus coagulase-negativa resistente à eritromicina, oxacilina e clindamicina. Em menor freqüência, Pseudomonas aeruginosa resistente à sulfametoxazol/trimetoprim e ampicilina; Acinetobacter baumannii resistente à ceftazidima; Enterobacter cloacae resistente à cefalotina, cefoxitina, cefazolina, levofloxacina, ciprofloxacina; Bacillus spp. e Candida tropicalis. A observação ao microscópio de fluorescência demonstrou agrupamentos celulares vivos envoltos em substância transparente. O teste de aderência dos Staphylococcus coagulase-negativa à placa de poliestireno mostrou que estes microrganismos são produtores de polissacarídeo extracelular. Em conclusão, os conjuntos metálicos foram colonizados por bactérias relacionadas à infecção de implantes ortopédicos, os quais apresentaram resistência múltipla aos antimicrobianos.


In the majority of cases of bone fracture requiring surgery, orthopedic implants (screw-plate and screw) are used for osteosynthesis and the infections associated with such implants are due to the growth of microorganisms in biofilms. The objective of this study was to identify microorganisms recovered from osteosynthesis implants used to fix bone fractures, to assess the viability of the cells and the ability of staphylococci to adhere to a substrate and to determine their sensitivity/resistance to antimicrobials. After surgical removal, the metal parts of austenitic stainless steel (ASTM F138/F139 or ISO NBR 5832-1/9) were transported to the Laboratory of Clinical Microbiology, washed in buffer and subjected to ultrasonic bath at 40±2 kHz for 5 minutes. The sonicated fluid was used to seed solid culture media and cell viability was assessed under the microscope by with the aid of a fluorescent marker. The production of extracellular polysaccharide by Staphylococcus spp. was investigated by means of adhesion to a polystyrene plate. The profile of susceptibility to antimicrobials was determined by the disk diffusion assay. The most frequently isolated bacteria included coagulase-negative Staphylococcus resistant to erythromycin, clindamycin and oxacillin. Less frequent were Pseudomonas aeruginosa resistant to trimethoprim/sulfamethoxazole and ampicillin, Acinetobacter baumannii resistant to ceftazidime, Enterobacter cloacae resistant to cephalothin, cefoxitin, cefazolin, levofloxacin and ciprofloxacin, Bacillus spp. and Candida tropicalis. The observation of slides by fluorescence microscope showed clusters of living cells embedded in a transparent matrix. The test for adherence of coagulase-negative Staphylococcus to a polystyrene plate showed that these microorganisms produce extracellular polysaccharide. In conclusion, the metal parts were colonized by bacteria related to orthopedic implant infection, which were resistant to multiple antibiotics.


Subject(s)
Fracture Fixation, Internal , Prostheses and Implants , Sonication
11.
Dental press j. orthod. (Impr.) ; 17(6): 24e1-24e7, Nov.-Dec. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-669389

ABSTRACT

OBJECTIVE: This in vitro study verified the resistance to corrosion of metallic brackets, evaluating the superficial aspects in scanning electron microscopy (SEM) and the residual components. METHODS: The sample consisted of 17 sets of brackets of four different metallic alloys: Titanium, Cobalt-Chromium, Stainless steel with low nickel concentration and with titanium nitride coating (NiTi). Twelve sets were submitted to corrosion by immersion in 50 ml of artificial saliva (pH 6.5) and four in saliva (pH 6.5) containing fluoride (2 g/l), all at a temperature of 37 ºC and analyzed after 7, 9 and 11 weeks. One was kept as control set. The analysis consisted in qualitative evaluation of the corrosion by the images obtained on the SEM, in semi-quantitative evaluation of chemical composition of the surface residue by SEM-EDS and the amount of ions released in saliva on evaluation of atomic absorption spectrophotometry. RESULTS: The results showed that the pure titanium brackets and the ones with low nickel concentration were superior regarding resistance to corrosion. The cobalt-chromium alloy showed the greatest corrosion. In the presence of fluoride, it was observed greater variation in all alloys, especially in the ones of NiTi coated steel and the ones of cobalt-chromium. CONCLUSION: Although observed corrosion on the SEM, the spectrophotometry showed low ions release in the artificial saliva, however, the presence of fluoride negatively affected the corrosion resistance.


OBJETIVO: este estudo in vitro verificou a resistência à corrosão de braquetes metálicos, avaliando-se os aspectos superficiais em microscopia eletrônica de varredura (MEV) e os componentes residuais formados. MÉTODOS: a amostra consistiu de 17 conjuntos de braquetes de quatro diferentes ligas metálicas: titânio, cobalto-cromo, aço inoxidável com baixa concentração de níquel e com cobertura de nitreto de titânio (TiN). Doze conjuntos foram submetidos à corrosão por imersão em 50ml de saliva artificial (pH 6,5) e 4 em saliva (pH 6,5) contendo flúor (2g/l), todos sob temperatura de 37ºC, e analisados após 7, 9 e 11 semanas. Uma montagem foi mantida como controle. As análises consistiram na avaliação qualitativa da corrosão por meio das imagens obtidas no MEV, na avaliação semiquantitativa da composição química dos resíduos superficiais por meio de MEV-EDS e da quantidade de íons liberados nas salivas na avaliação da espectrofotometria de absorção atômica. RESULTADOS: os resultados demonstraram que os braquetes com liga de titânio puro e os de aço com baixa concentração de níquel foram superiores em relação à resistência à corrosão. A liga de cobalto-cromo foi a que apresentou maior corrosão. Na presença do flúor, observaram-se maiores alterações em todas as ligas, com destaque para as de aço cobertos com TiN e as de cobalto-cromo. CONCLUSÃO: apesar de se observar a corrosão no MEV, a espectrofotometria mostrou baixo desprendimento de íons nas salivas artificiais, porém a presença do flúor interferiu negativamente na resistência à corrosão.

12.
Dental press j. orthod. (Impr.) ; 17(4): 51-56, July-Aug. 2012. ilus
Article in English | LILACS | ID: lil-653501

ABSTRACT

OBJECTIVE: The aim of this study was to assess resistance to sliding of stainless steel passive self-ligating brackets with 0° and 2.5° angulations and to compare them to active self-ligating brackets at zero angulation. The hypothesis to be tested was that passive self-ligating brackets produce lower frictional forces than active self-ligating brackets. METHODS: Twenty five 0.022 x 0.028-in slot maxillary canine brackets were divided into 5 groups of 5 brackets: Damon SL II (Ormco, CA, USA) self-ligating bracket and Gemini (3M/Unitek, CA, USA) conventional bracket with angulation of 0 and 2.5° and a group of Speed 2 (American Orthodontics, WI, USA) active clip self-ligating system with zero angulation. Twenty five segments of stainless steel 0.020-in archwire (TP Orthodontics, IN, USA) were tested and each bracket/wire interface was evaluated at 4 successive points during sliding. Overall, 100 frictional values were analyzed by parametric analysis of variance and Bonferroni tests. RESULTS AND CONCLUSION: Frictional tests were performed with an Emic DL 10000 testing machine (Emic, Brazil) with a load cell of one kilogram. Passive self-ligating brackets produced lower frictional forces than active self-ligating brackets (p < 0.01). Under angulation, brackets with a slide mechanism produced higher friction than the same brackets under zero angulation (p < 0.01). Nevertheless, the slide system under angulation produced smaller friction values than conventional brackets tied with elastomeric ligatures in 0° tests.


OBJETIVO: avaliar a fricção apresentada por braquetes autoligáveis de aço inoxidável com sistema passivo de tampa deslizante sob angulação de 0 grau e 2,5 graus, e comparar o comportamento desse grupo sob angulação nula com o de um grupo de braquetes autoligáveis com sistema ativo de tampa resiliente. MÉTODOS: foram utilizados 25 braquetes de caninos superiores, divididos em 5 grupos - braquetes autoligáveis passivos Damon SL II sob angulação de 0 grau e de 2,5 graus; braquetes convencionais Gemini amarrados com ligaduras elásticas sob as mesmas angulações; e um grupo formado pelo sistema ativo Time 2, sob angulação nula. A hipótese a ser testada é se artefatos autoligáveis com sistema de tampa passiva são mais efetivos no controle da fricção do que dispositivos contendo coberturas ativas. O tracionamento foi realizado segundo emprego de 25 segmentos de fio de aço inoxidável 0,020" na máquina de ensaios EMIC DL 10000 com célula de carga de 2,0kg. Cada conjunto braquete/fio foi responsável pela geração de quatro corpos de prova, totalizando-se 100 leituras. As comparações entre médias dos valores foram realizadas através da Análise de Variância (one-way ANOVA) com correções pelo coeficiente de Bonferroni. RESULTADOS E CONCLUSÃO: as médias de fricção encontradas confirmaram a hipótese em teste, de que o sistema de braquetes Damon SL II é mais eficiente no controle do atrito do que o sistema de tampa ativa sob angulação de 0 grau (p<0,01). Quando submetidos a angulações de 2,5 graus, a fricção aumentou significativamente (p<0,01), porém mantendo-se ainda muito inferior aos patamares evidenciados no grupo de braquetes convencionais amarrados com ligaduras elásticas.

13.
Dental press j. orthod. (Impr.) ; 16(4): 35.e1-35.e7, jul.-ago. 2011. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-604321

ABSTRACT

OBJETIVO: o objetivo do presente trabalho foi determinar a força de atrito estático entre braquetes de aço inoxidável autoligados com sistema de fechamento resiliente e fios ortodônticos redondos e retangulares do mesmo material. MÉTODOS: empregaram-se 30 braquetes referentes aos caninos superiores divididos em 6 grupos formados por braquetes autoligados Smartclip, In-Ovation R e convencionais Gemini amarrados com ligaduras elásticas. A hipótese testada neste trabalho foi quanto à possibilidade dos braquetes autoligados ativos serem suscetíveis à elevação da força de atrito com o aumento e alteração da secção transversal dos fios ortodônticos. Os ensaios foram realizados com tração de 30s em fios de aço inoxidável 0,020" e 0,019"X0,025" na máquina de ensaios Emic DL 10000, com uma célula de carga de 20 newtons. Cada conjunto braquete/fio foi responsável pela geração de quatro corpos de prova, totalizando 120 leituras. As comparações entre as médias foram realizadas através da Análise de Variância (one way ANOVA) com correções pelo coeficiente de Bonferroni. RESULTADOS E CONCLUSÃO: os braquetes autoligados apresentaram maior força de atrito do que os braquetes convencionais amarrados com ligaduras elásticas. O grupo Smartclip foi o mais efetivo no controle do atrito (p<0,01). A hipótese em teste, influência da forma da seção transversal do fio na força de atrito, foi confirmada, uma vez que os fios de secção retangular 0,019"X0,025" apresentaram maior força de atrito ao serem tracionados do que os fios redondos 0,020" (p<0,01). O sistema Smartclip foi mais efetivo mesmo quando o tracionamento de fios retangulares foi comparado com o ensaio de braquetes In-Ovation R conjugados a fios redondos (p<0,01).


OBJECTIVES: The purpose of this study was to assess the surface friction produced by self-ligating stainless steel brackets equipped with a resilient closure system and compare the friction generated during traction of round and rectangular orthodontic wires made from the same material. METHODS: Thirty maxillary canine brackets were divided into six groups comprising SmartClip and In-Ovation R self-ligating brackets, and conventional Gemini brackets tied with elastomeric ligatures. This investigation tested the hypothesis that self-ligating brackets are susceptible to increases in friction that are commensurate with increases and changes in the cross-section of orthodontic wires. Traction was performed with the aid of thirty segments of 0.020" and 0.019" x 0.025" stainless steel wires in an EMIC DL 10000 testing machine with a 2N load cell. Each set of bracket/wire generated four samples, totaling 120 readings. Comparisons between means were performed using analysis of variance (one way ANOVA) corrected with the Bonferroni coefficient. RESULTS AND CONCLUSION: The self-ligating brackets exhibited lower friction than conventional brackets tied with elastomeric ligatures. The SmartClip group was the most effective in controlling friction (p <0.01). The hypothesis under test was confirmed to the extent that the traction performed with rectangular 0.019" x 0.025" cross-section wires resulted in higher friction forces than those observed in the 0.020" round wire groups (p<0.01). The SmartClip system was more effective even when the traction produced by rectangular wires was compared with the In-Ovation R brackets combined with round wires (p<0.01).


Subject(s)
Orthodontic Brackets , Friction , Orthodontic Wires , Stainless Steel , Orthodontics
14.
Article in Portuguese | LILACS, BBO | ID: lil-618563

ABSTRACT

O aço inoxidável é um dos principais materiais empregados na fabricação de instrumentais cirúrgicos devido à combinação de propriedades mecânicas adequadas e elevada resistência à corrosão. Apesar de apresentar uma resistência à corrosão superior à maioria dos metais, em meios muito agressivos os aços inoxidáveis podem sofrer algum tipo de corrosão, podendo prejudicar de alguma forma sua durabilidade ou aparência. Este trabalho apresenta características e resultados de ensaios realizados em um cisalhador de placas de titânio com propósito de avaliar a resistência à corrosão do aço inoxidável M340. O objetivo principal deste estudo é determinar as resistências à esterilização em autoclave, à corrosão e à exposição térmica dos instrumentais cirúrgicos (cisalhador de placas de titânio) fabricadas em aço inoxidável.


tainless steel is one of the main materials used in the manufacture of surgical instruments through the combination of mechanical properties and high corrosion resistance. Despite presenting a corrosion resistance superior to most metals in very aggressive media stainless steels can suffer some type of corrosion, may somehow undermine their durability or appearance. This paper presents features and results of tests on a shear of titanium plates with purpose of evaluating the corrosion resistance of stainless steel M340. The main objective of this study is to determine the resistance to autoclaving, corrosion and thermal exposure of the surgical instruments (shear titanium plates) made of stainless steel.


Subject(s)
Dental Implants , Stainless Steel , Surgical Instruments
15.
RSBO (Impr.) ; 7(3): 312-319, jul.-set. 2010. ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-553604

ABSTRACT

Introdução e objetivo: Este estudo teve como objetivo analisar a influência do grau de curvatura na ocorrência de desvios apicais após a realização do preparo oscilatório. Material e métodos: Utilizaram-se 20 canais simulados com 21 mm de comprimento, os quais foram divididos em dois grupos experimentais com curvaturas de 20° e 40°. Os canais foram preparados com instrumentos de aço inoxidável acoplados a um contra-ângulo de sistema automatizado de movimentos oscilatórios com redução da velocidade de 10:1. Para a realização da análise do desvio, antes e após o preparo, os canais foram preenchidos com tinta nanquim e fotografados de forma padronizada com o auxílio de uma plataforma. Em seguida, as imagens obtidas foram manipuladas no programa Adobe Photoshop®, sobrepondo a imagem pré e pós-operatória, e com a ferramenta régua fez-se a medição dos desvios a 1 mm do comprimento de trabalho e no meio da área de curvatura. Os dados obtidos foram submetidos à Análise de Variância (Anova) com nível de significância de 5%. Resultados e conclusão: Por meio dos resultados obtidos observou-se que, quanto maior o grau de curvatura, maior foi o desvio. Já em relação ao local de análise, notou-se que na região a 1 mm do comprimento de trabalho houve maior desvio do que no ponto localizado no meio da área de curvatura.


Introduction and objective: This study aims to analyze the influence of degree of curvature in the occurrence of apical deviations after the oscillatory preparation. Material and methods: Twenty simulated root canals of 21 mm in length were divided into two experimental groups according to the degree of curvature: 20° and 40°. The canals were prepared using stainless steel instruments connected to a 10:1 speed reducing contra-angle handpiece with an automatized system of oscillatory movement. When analyzing the deviation, canals were filled with India ink and photographed in a standardized way with the aid of a platform, before and after the accomplishment of the preparation. In sequence, the images obtained were manipulated in Photoshop® Adobe program, preoperative and postoperative images were overlapped, and the deviation was measured with a ruler within 1 mm of working length and in the halfway of curvature. Data were submitted to analysis of variance (Anova) with a significance level of 5%. Results and conclusion: Through the results obtained, it was possible to see that the greater the degree of curvature, the greater the deviation. In relation to the place of analysis, it was possible to realize that there was more deviation in the region of 1 mm of working length than in the halfway of curvature.

16.
Innov. implant. j., biomater. esthet. (Impr.) ; 5(2): 40-44, maio-ago. 2010. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-581346

ABSTRACT

O aço inoxidável é um dos principais materiais empregados na fabricação de fresas odontológicas devido à combinação de propriedades mecânicas adequadas e elevada resistência à corrosão. Apesar de apresentar uma resistência à corrosão superior à maioria dos metais, em meios muito agressivos os aços inoxidáveis podem sofrer algum tipo de corrosão, podendo prejudicar de alguma forma sua durabilidade ou aparência. Este trabalho apresenta características e resultados de ensaios realizados em fresas odontológicas com propósito de avaliar a resistência à corrosão do aço inoxidável M340. O objetivo principal deste estudo é determinar as resistências à esterilização em autoclave, à corrosão e à exposição térmica dos instrumentais cirúrgicos (fresas odontológicas) fabricadas em aço inoxidável.


Stainless steel is one of the main materials used in the manufacture of dental burs due to the combination of mechanical properties and high resistance to corrosion. Despite presenting a corrosion resistance superior to most metals, in very aggressive to stainless steels may suffer some form of corrosion that may impair in any way their durability or appearance. This paper presents features and results of tests on dental burs in order to evaluate the corrosion resistance of stainless steel M340. The objective of this study is to determine the resistance to autoclaving, corrosion and thermal exposure of the surgical instruments (dental burs) made of stainless steel.


Subject(s)
Surgical Instruments , Dental Instruments , Stainless Steel
17.
Ortho Sci., Orthod. sci. pract ; 3(11): 207-213, 2010. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-576700

ABSTRACT

Este estudo teve como objetivo testar a resistência ao deslizamento de braquetes nacionais estéticos sobre fio ortodôntico de aço inoxidável nacional. Foram utilizados seis diferentes tipos de braquetes (Grupo 1 - Compósito Cristal Tecnident, Grupo 2 - Compósito com Canaleta de Metal Tecnident, Grupo 3 - Cerâmico Abzil, Grupo 4 - Cerâmico Tecnident, Grupo 5 – Compósito Morelli, Grupo 6 - Metálico Morelli utilizado como controle) e dois tipos de fios de aço inoxidável fio 1 (0,018”) e fio 2 (0,016 x 0,022”). Na máquina de testes universais Emic DL2000, a força necessária para a condução do braquete através do fio (pico máximo) foi registrada sob a forma de Gráfico - força x tempo, nas duas espessuras de fio separadamente. Verificou-se que o Grupo 1 e o Grupo 5 assemelham-se tendo as forças de deslizamento menores e pouca variabilidade. Já para os Grupos 3 e 4 produziram os maiores valores de forças de deslizamento. Os Grupos 2 e 6 controle apresentaram valores intermediários aos demais. O fio 2 (0,016 x 0,022”) produziu maior valor de força de resistência ao deslizamento. Pôde-se concluir que os braquetes de compósito nacionais produziram menor resistência a mecânica de deslize (atrito), comparáveis aos braquetes metálicos, sendo uma alternativa viável para os tratamentos com demanda estética.


The aim of this study was avaluate the resistance to sliding of national aesthetic brackets with stainless steel orthodontic wires. Six different kind of brackets were separate in six groups (G1 - Composite Cristal Tecnident, G2 - Composite with metal “slot” insert Tecnident, G3 – Ceramic Abzil, G4 - Ceramic Tecnident, G5 - Composite Morelli, G6 – Conventional Stainless Steel Morelli as a control group) and two kind of orthodontic stainless steel arch-wires A1 (0.018”) and A2 (0.016 X 0.022”). On the universal testing machine (Emic DL2000), the strengh needed on the traction of each one of 18 specimens was recorded in a graffic – strength X time, for the two dimensions of arch-wires individually. The results showed that G1 and G5 had the lower values of resistance to sliding and little variability. The group G3 and G4 showed the highest scores of resistance to sliding. Group 2 showed low score but with great variability, and G6 control group had scores lower than the G3 and G4 groups but was higher than G1, G2 and G5. On the arch-wires comparison the A1 showed lower values than the A2 arch-wire. It was concluded that the national composite brackets produced lower resistance to sliding mechanics (friction), comparable to metal brackets, being a viable alternative to the treatments with aesthetic demands.


Subject(s)
Materials Testing , Orthodontic Brackets , Tooth Attrition
18.
Rev. bras. ortop ; 44(5): 380-385, set.-out. 2009. ilus
Article in Portuguese | LILACS | ID: lil-531469

ABSTRACT

Os autores fazem uma ampla revisão da literatura destacando o emprego de hastes intramedulares flexíveis no tratamento de fraturas em crianças. Destacam o tratamento das fraturas diafisárias do fêmur e dos ossos do antebraço e enfatizam também a importância da abordagem não cirúrgica. A idade e o peso limite das crianças ainda não estão bem definidos para o emprego do método. A retirada de implantes tem destaque controverso na literatura, com tendência da permanência dos implantes.


The authors present a comprehensive review of the literature emphasizing the use of flexible intramedullary nails in the treatment of fractures in children, focusing the treatment of femoral shaft and forearm fractures and emphasizing the importance of the non-surgical approach. Children's age and weight threshold are not well defined for the use of the method. The removal of implants is a controversial matter in the literature, with a trend towards keeping the implants.


Subject(s)
Humans , Child , Fracture Fixation, Intramedullary , Fracture Fixation/methods , Internal Fixators , Orthopedic Fixation Devices , Stainless Steel , Titanium
19.
Rev. bras. odontol ; 66(1): 93-96, jan.-jun. 2009. tab
Article in Portuguese | LILACS, BBO | ID: lil-575391

ABSTRACT

O objetivo deste trabalho foi avaliar a influência da liga metálica na flexibilidade de instrumentos endodônticos. Foram utilizados instrumentos endodônticos de aço inoxidável e de NiTi de 25 mm de comprimento útil, conicidadede 0,02 mm/mm e de números 40 e 45. A flexibilidade dos instrumentos foi determinada por meio de um ensaio de flexão em cantilever. Com base nos resultados experimentais obtidos, pode-se concluir que entre os instrumentos endodônticos tipo K de mesmo número, os de NiTi são mais flexíveis e menos rígidos do que os de aço inoxidável.


Subject(s)
Dental Instruments/standards , Nickel , Pliability , Root Canal Preparation/instrumentation , Stainless Steel , Titanium
20.
Rev. bras. ortop ; 43(7): 261-270, jul. 2008. ilus
Article in Portuguese | LILACS | ID: lil-492428

ABSTRACT

O tratamento de algumas das fraturas da criança tem sofrido modificações nos últimos anos, com o objetivo de obtenção de resultados mais satisfatórios, restrição do tempo de incapacidade e para melhor corresponder às expectativas da família. Isso é especialmente válido para as fraturas diafisárias de alguns ossos longos com o tratamento feito por hastes intramedulares elásticas. Esse tratamento é de baixa morbidade, respeita a biologia e a biomecânica da fratura e permite consolidação óssea por mecanismo secundário, com a formação de calo ósseo. Entretanto, requer implantes, instrumental e conhecimento técnico do cirurgião, pois os maus resultados relacionam-se diretamente com falhas técnicas. Atualmente, os ossos que mais se prestam para esse tipo de fixação, em relação à prioridade, são: fêmur, rádio, ulna, tíbia e úmero. O objetivo deste texto de atualização foi analisar a literatura e fornecer informações fundamentais para o conhecimento do método.


The treatment of some fractures in children has changed over the last years aiming at improving results, shortening the time of physical limitation, and meeting family expectations. This is particularly true when long bone shaft fractures are involved and when treatment is carried out with elastic nails. This technique carries low morbidity, respects the biology and the biomechanics of the reparative process and allows secondary healing with osseous callus formation. Nevertheless, the technique requires adequate surgical implants, proper instruments and trained surgeons, since complications are related mainly to technical pitfalls. The technique has been used for the following bones: femur, radius and ulna, tibia and humerus. The objective of the present update was to review and to analyze the literature so as to present basic information about the treatment of diaphyseal fractures of some long bones of children with flexible nails.


Subject(s)
Humans , Child , Fracture Fixation, Internal , Fracture Fixation, Intramedullary , Fracture Fixation/methods , Orthopedic Fixation Devices , Stainless Steel , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL