Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Article in English | LILACS-Express | LILACS | ID: biblio-1529493

ABSTRACT

ABSTRACT Objective: To compare and analyze pulmonary function and respiratory mechanics parameters between healthy children and children with cystic fibrosis. Methods: This cross-sectional analytical study included healthy children (HSG) and children with cystic fibrosis (CFG), aged 6-13 years, from teaching institutions and a reference center for cystic fibrosis in Florianópolis/SC, Brazil. The patients were paired by age and sex. Initially, an anthropometric evaluation was undertaken to pair the sample characteristics in both groups; the medical records of CFG were consulted for bacterial colonization, genotype, and disease severity (Schwachman-Doershuk Score — SDS) data. Spirometry and impulse oscillometry were used to assess pulmonary function. Results: In total, 110 children were included, 55 in each group. In the CFG group, 58.2% were classified as excellent by SDS, 49.1% showed the ΔF508 heterozygotic genotype, and 67.3% were colonized by some pathogens. Statistical analysis revealed significant differences between both groups (p<0.05) in most pulmonary function parameters and respiratory mechanics. Conclusions: Children with cystic fibrosis showed obstructive ventilatory disorders and compromised peripheral airways compared with healthy children. These findings reinforce the early changes in pulmonary function and mechanics associated with this disease.


RESUMO Objetivo: Comparar e analisar parâmetros de função pulmonar e de mecânica respiratória entre escolares saudáveis e com fibrose cística (FC). Métodos: Estudo transversal que incluiu escolares saudáveis (GES) e com FC (GFC), com idades entre seis e 13 anos, provenientes de instituições de ensino e de um centro de referência da FC em Florianópolis/SC, Brasil, pareados por idade e sexo, respectivamente. Inicialmente, conduziu-se avaliação antropométrica para pareamento e caracterização de ambos os grupos e, no GFC, consultou-se prontuário médico para registro dos dados de colonização bacteriana, genótipo e gravidade da doença (Escore de Schwachman-Doershuk — ESD). Para a avaliação da função pulmonar, realizou-se espirometria e a avaliação da mecânica respiratória foi conduzida por meio do sistema de oscilometria de impulso. Resultados: Participaram 110 escolares, 55 em cada grupo. No GFC, 58,2% foram classificados pelo ESD como excelentes, 49,1% apresentaram genótipo ∆F508 heterozigoto e 67,3% eram colonizados por alguma patógeno. Houve diferença significativa (p<0,05) na maioria dos parâmetros de função pulmonar e de mecânica respiratória entre os grupos. Conclusões: Escolares com FC apresentaram distúrbio ventilatório obstrutivo e com comprometimento de vias aéreas periféricas, em comparação aos escolares hígidos. Esse evento reforça o início precoce da alteração de função pulmonar e de mecânica respiratória nessa enfermidade, evidenciados pelos achados desta investigação.

2.
Rev. chil. enferm. respir ; 39(3): 2016-225, 2023. tab, graf
Article in Spanish | LILACS | ID: biblio-1521830

ABSTRACT

Introducción: Se han informado patrones de deterioro temprano de la función pulmonar en el asma pediátrica. Nuestro objetivo fue identificar las trayectorias de la función pulmonar en la espirometría, desde la edad preescolar hasta la edad escolar. Materiales: Estudio prospectivo realizado entre el 2016 y el 2021. Se reclutaron pacientes con asma persistente a quienes se les realizó oscilometría de impulso (IOS)-espirometría al inicio y después de 3 años. La espirometría anormal se definió de acuerdo con las guías ATS/ERS. Métodos: se utilizó χ2 y ANOVA para comparar las características clínicas y promedios de parámetros de la espirometría e IOS entre trayectorias. Resultados: 86 pacientes, promedio de edad 5,3 y 8,3 años en su primera y segunda evaluación. El 70,9% de los pacientes mantuvo la espirometría normal en ambas evaluaciones (trayectoria 1), el 9,3% presentó espirometría preescolar anormal que normalizó en la edad escolar (trayectoria 2) y el 19,8% espirometría en anormal en ambas evaluaciones (trayectoria 3). La trayectoria 3 registró menor peso promedio al nacer (2,4 kg vs 3,02 kg p = 0,04), mayor promedio de exacerbaciones (5,3 vs 2,01 p = 0,00002), mayor promedio de hospitalizaciones (0,61 vs 0,16 p = 0,04), parámetros promedio más bajos en espirometría (relación VEF1/CVF %, relación VEF0,75/CVF %, VEF0,75 L, VEF0,5 L), promedios más bajos en X5 kPa/Ls y más altos en AX kPa/Ls, que la trayectoria 1. Conclusiones: La trayectoria 1 fue la más frecuente, con persistencia de función pulmonar normal. La trayectoria 3, la segunda más frecuente, inició seguimiento con función pulmonar disminuida en la espirometría y disfunción de vía aérea pequeña en el IOS que se mantuvo en la edad escolar. Los niños que siguieron la trayectoria 3 tuvieron menor peso al nacer, más exacerbaciones y hospitalizaciones que los niños de la trayectoria 1.


Introduction: Patterns of early decline in lung function have been reported in pediatric asthma. Our objective was to identify pulmonary function trajectories in spirometry, from preschool age to school age. Materials: Prospective study conducted between 2016 and 2021. Patients with persistent asthma who underwent impulse oscillometry (IOS)-spirometry at baseline and after 3 years were recruited. Abnormal spirometry was defined according to ATS/ERS guidelines. Methods: χ2 and ANOVA was used to compare clinics characteristics and means of IOS-spirometry parameters between trajectories. Results: 86 patients, mean age of 5,3 and 8,3 years in their first and second evaluation. 70.9% of the patients maintained normal spirometry in both evaluations (Track 1), 9.3% presented abnormal preschool spirometry that normalized at school age (Track 2) and 19.8% abnormal spirometry in both evaluations (Track 3). Trajectory 3 had a lower average birth weight (2,4 kg vs 3,02 kg p = 0,04), higher average of exacerbations (5,3 vs 2,01 p = 0,00002), higher average of hospitalizations (0,61 vs 0,16 p = 0,04), lowest averages parameters in spirometry (FEV1/FVC % ratio, FEV0,75/FVC % ratio, FEV0,75 L, FEV0,5 L), lower average in X5 kPa/Ls and higher in AX kPa/Ls, than trajectory 1. Conclusions: Trajectory 1 was the most common, with persistent normal lung function. Trajectory 3, the second most frequent, started follow-up with decreased lung function in spirometry and small airway disfunction in the IOS that were maintained at school age. Children who followed trajectory 3 had lower birth weight, more exacerbations, and hospitalizations than children in trajectory 1.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Asthma/physiopathology , Oscillometry , Spirometry , Vital Capacity , Forced Expiratory Volume , Prospective Studies , Analysis of Variance
3.
Arq. neuropsiquiatr ; 80(12): 1233-1238, Dec. 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1439406

ABSTRACT

Abstract Background Parkinson's disease (PD) causes a series of movement disorders, many of them starting in the early stage. Objective To analyze the pulmonary function of mild-stage subjects with PD and to investigate the effects of levodopa on it. Methods We included 21 patients with idiopathic PD and 20 healthy control subjects. The participants were submitted to spirometry and impulse oscillometry assessments. The PD patients were evaluated during the "off" and "on" phases of their anti-PD medication, which was was converted to levodopa in an equivalent daily dose. A statistical analysis was performed with cross-sectional (PD patients "off" medication versus controls) and paired (PD patients "off" medication versus PD patients "on" medication) tests. The effect of levodopa was calculated with partial Eta-squared (η2ρ). Significance was set at 5%. Results The PD patients presented normal values in the impulse oscillometry. Regarding spirometry, the results indicated an incipient obstructive ventilatory disorder in the PD group - confirmed by patients' flow-volume curves. The PD patients received a daily dose of 354.7 ± 148.2 mg of levodopa. The paired analyses showed a small effect of anti-PD medication on pulmonary parameters (η2ρ = 0.197 for spirometry and η2ρ = 0.043 for impulse oscillometry). Conclusion Patients with PD in the mild stage of the disease present pulmonary compliance and resistance compatible with normal parameters. The differences regarding the spirometric results indicate an incipient obstructive ventilatory disorder in patients with PD. Levodopa had small effect on pulmonary function in the mild stage of the disease.


Resumo Antecedentes A doença de Parkinson (DP) causa uma série de distúrbios do movimento, muitos deles se desenvolvendo na fase inicial. Objetivo Analisar função pulmonar de pessoas com DP em estágio leve e investigar o efeito da levodopa nesse processo. Métodos Vinte e um participantes com DP idiopática e vinte controles saudáveis foram incluídos na pesquisa. Todos os sujeitos foram submetidos a avaliações de espirometria e oscilometria de impulso. Participantes com DP foram avaliados nas fases 'on' e 'off' de medicação anti-parkinsoniana. A medicação dos pacientes foi convertida em dose diária de levodopa. A análise estatística foi realizada com testes transversais (Parkinson na fase 'off' da medicação vs controles) e pareados (Parkinson nas fases 'off' vs 'on' da medicação). O efeito da levodopa foi calculado pelo eta ao quadrado parcial (η2ρ). Significância foi estipulada em 5%. Resultados Pacientes com DP apresentaram valores normais na oscilometria de impulso. Na espirometria, os resultados indicaram uma desordem ventilatória obstrutiva incipiente no grupo DP - confirmada pelas curvas fluxo-volume dos pacientes. Pacientes com DP receberam uma dose diária de 354,7 ± 148,2 miligramas de levodopa. Análises pareadas mostraram baixo impacto da medicação anti-parkinsoniana nos parâmetros pulmonares (η2ρ = 0,197 na espirometria e η2ρ = 0,043 na oscilometria de impulso). Conclusão Pacientes com DP na fase leve apresentam complacência e resistência pulmonares compatíveis com parâmetros normais. Diferenças espirométricas indicam distúrbio ventilatório obstrutivo incipiente em pacientes com DP. A administração de levodopa apresentou baixo efeito na função pulmonar na fase leve da doença.

4.
Neumol. pediátr. (En línea) ; 17(3): 80-85, 2022. ilus
Article in Spanish | LILACS | ID: biblio-1418075

ABSTRACT

La Oscilometría de Impulso (IOS) es una técnica no invasiva que evalúa las propiedades mecánicas de todo el sistema respiratorio durante la respiración tranquila. Mide la impedancia total del sistema respiratorio, evaluando la resistencia total de la vía aérea, la resistencia de la vía aérea alta y las propiedades elásticas del pulmón. Detecta el compromiso de la vía aérea periférica en forma muy precoz, antes que la espirometría, y es útil en niños pequeños porque no requiere maniobras de espiración forzada. Permite evaluar la respuesta broncodilatadora y broncoconstrictora a través de pruebas de provocación bronquial para el diagnóstico de hiperreactividad bronquial. La IOS tiene un rol en la evaluación temprana y seguimiento de la función pulmonar en niños con enfermedades respiratorias crónicas, principalmente asma bronquial, displasia broncopulmonar y fibrosis quística. Este artículo revisa los aspectos fisiológicos, técnicos y aplicación clínica de la IOS, considerando las últimas recomendaciones para la estandarización del examen y las limitaciones que dificultan su interpretación .


Impulse Oscillometry (IOS) is a non-invasive technique that assesses the mechanical properties of the entire respiratory system during quiet breathing. It measures the total impedance of the respiratory system by evaluating total airway resistance, upper airway resistance, and elastic properties of the lung. It detects peripheral airway compromise very early, before spirometry, and is useful in young children because it does not require forced expiration maneuvers. It allows evaluating the bronchodilator and bronchoconstrictor response through bronchial provocation tests for the diagnosis of bronchial hyperreactivity. The IOS has a role in the early evaluation and monitoring of lung function in children with chronic respiratory diseases, mainly bronchial asthma, bronchopulmonary dysplasia and cystic fibrosis. This article reviews the physiological, technical, and clinical application aspects, considering the latest recommendations for the standardization of the test and the limitations that hinder its interpretation.


Subject(s)
Humans , Child , Oscillometry/methods , Respiratory Function Tests/methods , Respiratory Tract Diseases/physiopathology , Respiratory Physiological Phenomena , Respiratory Tract Diseases/diagnosis , Airway Resistance/physiology
5.
Rev. bras. enferm ; 75(4): e20210658, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1376585

ABSTRACT

ABSTRACT Objectives: to characterize oscillometric blood pressure measurement devices for sale in the virtual market and identify which ones have undergone a validation study. Methods: this was a cross sectional study. The search for devices for sale was conducted on websites, and the sample was composed of 137 devices obtained from 644 ads. We conducted a bibliographic survey in five databases and web pages enlisting devices submitted for validation. The Kolmogorov-Smirnov test was used to check data distribution, followed by Mann-Whitney and Kruskal-Wallis tests for comparisons, using the SAS 9.4 program. Results: only 16.7% of the devices were validated. The home devices ranged from USD 10.57 to USD 275.67. Only 102 ads informed the cuff size, with different nomenclatures. Conclusions: most ads contained non-validated devices, which were cheaper. We identified some ads falsely informing validation.


RESUMEN Objetivos: caracterizar aparatos oscilométricos de medición de la presión sanguínea a la venta en el mercado virtual e identificar cuales pasaron por estudio de validación. Métodos: discorre de un estudio transversal. La búsqueda de equipos a la venta fue realizada en páginas de internet, y la muestra fue composta por 137 equipos, obtenidos en 644 anuncios. Realizado levantamiento bibliográfico en cinco bases de datos y consultadas páginas de internet que registran equipos sometidos a validación. Utilizadas las pruebas Kolmogorov-Smirnov para verificación de la distribución de los datos, seguidos de Mann-Whitney y Kruskal-Wallis para comparaciones, mediante el programa SAS 9.4. Resultados: solamente 16,7% de los aparatos eran validados. Equipos domiciliares presentaron variancia de R$ 58,70 a R$ 1.531. Solo 102 anuncios informaron las dimensiones del brazalete, con nomenclaturas diferentes. Conclusiones: la mayoría de los anuncios contenía equipos no validados, que eran más baratos. Fueron identificados anuncios con informaciones falsas sobre validación.


RESUMO Objetivos: caracterizar os dispositivos oscilométricos de medida da pressão arterial à venda no mercado virtual e identificar quais passaram por estudo de validação. Métodos: trata-se de um estudo transversal. A busca dos aparelhos à venda foi realizada em páginas da internet, e a amostra foi composta por 137 aparelhos, obtidos em 644 anúncios. Foi realizado levantamento bibliográfico em cinco bases de dados e consultadas páginas da internet que registram aparelhos submetidos à validação. Utilizaram-se os testes Kolmogorov-Smirnov para verificação da distribuição dos dados, seguidos de Mann-Whitney e Kruskal-Wallis para comparações, por meio do programa SAS 9.4. Resultados: somente 16,7% dos dispositivos eram validados. Os aparelhos domiciliares apresentaram variação de R$ 58,70 a R$ 1.531. Apenas 102 anúncios informaram as dimensões da braçadeira, com nomenclaturas diferentes. Conclusões: a maioria dos anúncios continha aparelhos não validados, que eram mais baratos. Foram identificados anúncios com informações falsas sobre validação.

6.
J. bras. pneumol ; 48(1): e20210290, 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1360539

ABSTRACT

ABSTRACT Objective: To assess respiratory system impedance (Zrs) and spirometric parameters in children and adolescents with and without a history of preterm birth. Methods: We evaluated a sample of 51 subjects between 11 and 14 years of age: 35 who had a history of preterm birth (preterm group) and 16 who had been born at term (full-term group). Lung function was measured by spirometry, spectral oscillometry, and intra-breath oscillometry. Results: Neither spirometry nor spectral oscillometry revealed any statistically significant differences between the preterm and full-term groups. However, intra-breath oscillometry demonstrated significant differences between the two groups in terms of the change in resistance, reactance at end-inspiration, and the change in reactance (p < 0.05 for all). Conclusions: Our findings suggest that abnormalities in Zrs persist in children and adolescents with a history of preterm birth and that intra-breath oscillometry is more sensitive than is spectral oscillometry. Larger studies are needed in order to validate these findings and to explore the impact that birth weight and gestational age at birth have on Zrs later in life.


RESUMO Objetivo: Avaliar a impedância do sistema respiratório (Zsr) e parâmetros espirométricos em crianças e adolescentes com e sem história de prematuridade. Métodos: Foi analisada uma amostra de 51 indivíduos entre 11 e 14 anos de idade: 35 com história de prematuridade (grupo pré-termo) e 16 nascidos a termo (grupo a termo). A função pulmonar foi medida por meio de espirometria, oscilometria espectral e oscilometria intra-breath. Resultados: A espirometria e a oscilometria espectral não revelaram diferenças estatisticamente significativas entre os grupos pré-termo e a termo. No entanto, a oscilometria intra-breath demonstrou diferenças significativas entre os dois grupos quanto à alteração da resistência, à reatância ao final da inspiração e à alteração da reatância (p < 0,05 para todas). Conclusões: Nossos achados sugerem que as anormalidades na Zsr persistem em crianças e adolescentes com história de prematuridade e que a oscilometria intra-breath é mais sensível do que a oscilometria espectral. São necessários estudos maiores para validar esses achados e para explorar o impacto do peso e idade gestacional ao nascer na Zsr mais tarde na vida.

7.
Rev. chil. enferm. respir ; 37(4): 285-292, dic. 2021. tab
Article in Spanish | LILACS | ID: biblio-1388163

ABSTRACT

INTRODUCCIÓN: El incremento del índice de masa corporal afecta la función pulmonar en el asma. Objetivo: determinar si existen diferencias entre asmáticos con estado nutricional normal, sobrepeso y obesidad en cuanto a alteraciones de la oscilometría de impulso (IOS) y espirometría. MÉTODO: Estudio realizado en niños y adolescentes con asma persistente. Se practicó sucesivamente IOS y Espirometría pre y post- broncodilatador según criterios ATS/ERS/SER. Los pacientes se clasificaron en: eutróficos (AE), con sobrepeso (ASP) y obesos (AO). Se compararon promedios de valores basales y con respuesta broncodilatadora (RB) en espirometría e IOS, con análisis de varianzas ANOVA y test de Tukey post hoc. Se consideró un poder de 80% y error α de 5%. RESULTADOS: Se analizaron 559 pacientes, promedio de edad 9,2 años, 50,9% varones. AE 52,4%, ASP 31,3% y AO 16,3%. Se encontraron diferencias significativas entre AO vs AE (X5, AX, D5-20, VEF1/CVF, FEF25-75/CVF, RB VEF1), y entre ASP vs AE (AX, D5-20, VEF1/CVF). También se encontraron diferencias significativas en varones, no encontradas en las mujeres (X5, D5-20, VEF1/CVF, RB CVF, RB VEF1). CONCLUSIONES: Los niños asmáticos con sobrepeso y obesidad, tienen un mayor compromiso de los índices de función pulmonar medida por espirometría e IOS que los asmáticos con estado nutricional normal. Existen diferencias de género en las alteraciones espirometría e IOS.


INTRODUCTION: Increased body mass index asthma affects lung function in asthma. Objective: to determine if asthmatics with overweight or obesity have alterations in Impulse oscillometry (IOS) and spirometry compared to eutrophic METHOD: Study carried out in children and adolescents with persistent asthma. IOS-Spirometry pre and post bronchodilator were performed successively according to ATS/ERS/SER criteria. The patients were classified as: eutrophic (AE), overweight (ASP) and obese (OA). Baseline and bronchodilator response (BR) averages were compared in spirometry and IOS with ANOVA and Tukey's post hoc analysis of variance. A power of 80% and α error of 5% were considered. RESULTS: 559 patients were analyzed, mean age 9.2 years, 50.9% male. AE 52.4%, ASP 31.3% and OA 16.3%. Significant differences were found between OA vs AE (X5, AX, D5-20, FEV1/FVC, FEF25-75 / FVC, RB FEV1), and between ASP vs AE (AX, D5-20, FEV1/FVC). Significant differences were also found in men, not women (X5, D5-20, FEV1/FVC, BR FVC, BR FEV1). CONCLUSIONS: Asthmatic children with overweight and obesity have a greater compromise of pulmonary function parameters measured by spirometry and IOS than asthmatics with normal nutritional status. There are gender differences in spirometry and IOS alterations.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Respiratory Function Tests/methods , Asthma/physiopathology , Lung/physiopathology , Obesity/physiopathology , Oscillometry , Spirometry , Vital Capacity , Forced Expiratory Volume , Nutritional Status , Cross-Sectional Studies , Analysis of Variance , Overweight/physiopathology
8.
Neumol. pediátr. (En línea) ; 16(1): 5-10, 2021. ilus
Article in Portuguese | LILACS | ID: biblio-1284148

ABSTRACT

Asthma is considered the most prevalent chronic disease in children. The pulmonary function measurements are important in the evaluation of the disease, being able to confirm the diagnosis by demonstrating the reversibility of the obstruction as well as detecting risks of poor prognosis in the control of asthma. However, the most common methods for analyzing pulmonary function in this age group have restrictions on its applicability, especially due to the need for cooperation on the part of patients. The forced oscillation technique (FOT) is considered a modern tool capable of estimating measures of respiratory mechanics related to the lungs. This method is easily applicable due to the low need for patient cooperation, an important element in the assessment of children. The aim of this study is to review the clinical utility of the Forced Oscillation Technique in the pulmonary assessment of asthmatic children. The bibliographic search covered the years between 1950 and 2019, in the databases: Medical Literature Analysis and Retrieval System Online (MEDLINE) and Latin American and Caribbean Literature in Health Sciences (LILACS). It was used as a search strategy the combination of the following Medical Subject Headings (MeSH) terms: "asthma", "oscillometry" and "child" crossed through the AND and OR Boolean connectors. In asthmatic children, FOT showed greater accuracy in the evaluation of smaller caliber peripheral airways, which can be applied as a complementary method to spirometry to strengthen the diagnosis, enabling a better understanding of the disease and its progression.


A asma é considerada a doença crônica de maior incidência em crianças. As medidas de função pulmonar são importantes na avaliação da doença, podendo confirmar o diagnóstico pela demonstração de reversibilidade da obstrução assim como detectar riscos de mau prognóstico no controle da asma. Entretanto, os métodos mais usuais para análise da função pulmonar nesta faixa etária apresentam restrições em sua aplicabilidade, especialmente pela necessidade de cooperação por parte dos pacientes. A técnica de oscilações forçadas (FOT) é considerada uma ferramenta moderna capaz de estimar medidas da mecânica respiratória relativas aos pulmões. Este método apresenta fácil aplicabilidade pela baixa necessidade de cooperação do paciente, elemento importante na avaliação de crianças. O objetivo deste estudo é revisar a utilidade clínica da Técnica de Oscilações Forçadas na avaliação pulmonar de crianças asmáticas. A busca bibliográfica contemplou os anos entre 1950 e 2019, nas bases de dados: Medical Literature Analysis and Retrieval System Online (MEDLINE) e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS). Foi utilizada como estratégia de busca a combinação dos seguintes Medical Subject Headings(MeSH) terms: "asthma", "oscillometry" e "child" cruzados por meio dos conectores booleanos AND e OR. Em crianças asmáticas, a FOT mostrou maior acurácia na avaliação de vias aéreas periféricas de menor calibre, podendo ser aplicada como método complementar a espirometria para encorpar o diagnóstico, possibilitando compreender melhor a doença e sua progressão.


Subject(s)
Humans , Child , Oscillometry/methods , Respiratory Function Tests/methods , Asthma/diagnosis , Asthma/physiopathology , Spirometry , Respiratory Mechanics
9.
Rev. panam. salud pública ; 44: e88, 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1127118

ABSTRACT

RESUMEN La hipertensión arterial es una causa modificable muy prevalente de enfermedades cardiovasculares, accidentes cerebrovasculares y muerte. Medir con exactitud la presión arterial es fundamental, dado que un error de medición de 5 mmHg puede ser motivo para clasificar incorrectamente como hipertensas a 84 millones de personas en todo el mundo. En la presente declaración de posición se resumen los procedimientos para optimizar el desempeño del observador al medir la presión arterial en el consultorio, con atención especial a los entornos de ingresos bajos o medianos, donde esta medición se ve complicada por limitaciones de recursos y tiempo, sobrecarga de trabajo y falta de suministro eléctrico. Es posible reducir al mínimo muchos errores de medición con una preparación adecuada de los pacientes y el uso de técnicas estandarizadas. Para simplificar la medición y prevenir errores del observador, deben usarse tensiómetros semiautomáticos o automáticos de manguito validados, en lugar del método por auscultación. Pueden ayudar también la distribución de tareas, la creación de un área específica de medición y el uso de aparatos semiautomáticos o de carga solar. Es fundamental garantizar la capacitación inicial y periódica de los integrantes del equipo de salud. Debe considerarse la implementación de programas de certificación de bajo costo y fácilmente accesibles con el objetivo de mejorar la medición de la presión arterial.(AU)


ABSTRACT High blood pressure (BP) is a highly prevalent modifiable cause of cardiovascular disease, stroke, and death. Accurate BP measurement is critical, given that a 5-mmHg measurement error may lead to incorrect hypertension status classification in 84 million individuals worldwide. This position statement summarizes procedures for optimizing observer performance in clinic BP measurement, with special attention given to low-tomiddle- income settings, where resource limitations, heavy workloads, time constraints, and lack of electrical power make measurement more challenging. Many measurement errors can be minimized by appropriate patient preparation and standardized techniques. Validated semi-automated/automated upper arm cuff devices should be used instead of auscultation to simplify measurement and prevent observer error. Task sharing, creating a dedicated measurement workstation, and using semi-automated or solar-charged devices may help. Ensuring observer training, and periodic re-training, is critical. Low-cost, easily accessible certification programs should be considered to facilitate best BP measurement practice.(AU)


RESUMO A hipertensão é uma causa altamente prevalente de doença cardiovascular, acidente vascular cerebral e morte. A medição precisa da pressão arterial (PA) é um aspecto crítico, uma vez que erros de mensuração da ordem de 5 mmHg podem levar a uma classificação incorreta do status de hipertensão em 84 milhões de pessoas em todo o mundo. O presente posicionamento resume os procedimentos para otimizar o desempenho do observador (o indivíduo responsável pela mensuração da PA) na mensuração clínica da PA, com atenção especial para contextos de baixa a média renda, onde recursos limitados, cargas de trabalho pesadas, restrições de tempo e falta de energia elétrica tornam mais desafiadora a tarefa de medir a PA. Muitos erros de mensuração podem ser minimizados pela preparação adequada do paciente e pelo uso de técnicas padronizadas. Para simplificar a mensuração e evitar erros do observador, devem-se utilizar dispositivos semiautomatizados ou automatizados validados, com manguito para braço, ao invés de auscultação. O compartilhamento de tarefas, a criação de uma estação de trabalho dedicada à mensuração e o uso de dispositivos semiautomatizados ou com carga solar podem ajudar. É essencial que seja assegurado o treinamento e retreinamento periódico do observador. Programas de certificação de baixo custo e de fácil acesso devem ser considerados para facilitar a adoção das melhores práticas na mensuração da PA.(AU)


Subject(s)
Humans , Oscillometry , Blood Pressure Monitors/supply & distribution , Global Health/trends , Risk Measurement Equipment , Hypertension/prevention & control
10.
J. bras. pneumol ; 46(3): e20190021, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1386038

ABSTRACT

ABSTRACT Objective: To compare impulse oscillometry parameters between healthy children and adolescents with symptoms of rhinitis and those without. Methods: This was a cross-sectional analytical study of healthy individuals 7-14 years of age. Health status was determined through the use of questionnaires. We performed anthropometric measurements, impulse oscillometry, and spirometry. Results: The sample comprised 62 students, with a mean age of 9.58 ± 2.08 years and a mean body mass index (BMI) of 17.96 ± 3.10 kg/m2. The students were divided into two groups: those with symptoms of rhinitis (n = 29) and those without such symptoms (n = 33). The oscillometry results and anthropometric parameters were normal in both groups and did not differ significantly between the two. The variables age, height, and body mass, respectively, correlated negatively and moderately with most of the following parameters: total airway resistance (r = −0.529, r = −0.548, and r = −0.433); central airway resistance (r = −0.441, r = −0.468, and r = −0.439); respiratory impedance (r = −0.549, r = −0.567, and r = −0.455); reactance at 5 Hz (r = 0.506, r = −0.525, and r = −0.414); reactance area (r = −0.459, r = −0.471, and r = −0.358); and resonance frequency (r = −0.353, r = −0.371, and r = −0.293). We found that BMI did not correlate significantly with any of the parameters evaluated. The same was true when we analyzed each group in isolation. Conclusions: In our sample, impulse oscillometry parameters did not differ between the students who had symptoms of rhinitis and those who did not.


RESUMO Objetivo: Comparar parâmetros de impulso oscilométricos em crianças e adolescentes saudáveis com e sem sintomas de rinite. Métodos: Estudo transversal analítico com indivíduos saudáveis com idade de 7-14 anos. A higidez foi determinada por meio de questionários, e foram realizadas medições antropométricas, oscilometria de impulso e espirometria. Resultados: A amostra total foi composta por 62 escolares (média de idade = 9,58 ± 2,08 anos e média de índice de massa corpórea (IMC) = 17,96 ± 3,10 kg/m2). A amostra total foi dividida em grupos com (n = 29) e sem sintomas de rinite (n = 33), que apresentaram resultados normais nos parâmetros oscilométricos e antropométricos, sem diferenças entre os grupos. As variáveis idade, estatura e massa corporal, respectivamente, correlacionaram-se, em sua grande maioria, negativa e moderadamente com os parâmetros resistência total das vias aéreas (r = −0,529; r = −0,548; e r = −0,433), resistência central das vias aéreas (r = −0,441; r = −0,468; e r = −0,439), impedância respiratória (r = −0,549; r = −0,567; e r = −0,455), reatância a 5 Hz (r = 0,506; r = −0,525; e r = −0,414), área de reatância (r = −0,459; r = −0,471; e r = −0,358) e frequência de ressonância (r = −0,353; r = −0,371; e r = −0,293). O IMC não se correlacionou significativamente com os parâmetros avaliados. O mesmo comportamento foi observado analisando-se os grupos isoladamente. Conclusões: Em nossa amostra, escolares que apresentam sintomas de rinite não apresentaram alterações nos parâmetros de impulso oscilométricos quando comparados àqueles sem esses sintomas.

11.
Arq. bras. cardiol ; 113(2): 242-249, Aug. 2019. tab
Article in English | LILACS | ID: biblio-1019386

ABSTRACT

Abstract Background: Psoriasis correlates with metabolic disorders, early atheromatosis and increased cardiovascular risk. Objectives: To assess markers of cardiovascular disease in psoriatic patients. Methods: Cross-sectional, observational study involving 11 psoriatic participants and 33 controls. Anthropometric, biochemical, hemodynamic and imaging parameters were evaluated. Arterial stiffness was assessed by oscillometric measurement of the brachial artery. Intima-media thickness (IMT) and left ventricular diastolic function were assessed by Doppler echography and echocardiography. Between-group comparisons of numerical variables were performed by the Student's t-test or Wilcoxon Mann-Whitney test for independent samples. Significance level was set at 5%. Results: Psoriatic patients showed increased pulse wave velocity (PWV) (9.1 ± 1.8 vs 8.0 ± 2 m/s, p = 0.033), IMT of the left common carotid artery (p = 0.018) and a higher percentage of patients above the 75th percentile according to the ELSA table when compared with controls (54.5 vs 18.2%, p = 0.045). Psoriatic patients also showed an increase in peripheral/central systolic blood pressure (137.1 ± 13.2 vs 122.3 ± 11.6 mmHg, p = 0.004)/(127 ± 13 vs 112.5 ± 10.4 mmHg, p = 0.005), peripheral/central diastolic blood pressure (89.9 ± 8.9 vs 82.2 ± 8, p = 0.022)/(91 ± 9.3 vs 82.2 ± 8.3, p = 0.014), total cholesterol (252 ± 43.5 vs 198 ± 39.8 mg/dL, p < 0.001), LDL cholesterol (167 ± 24 vs 118 ± 40.8 mg/dL, p < 0.001) and C-reactive protein (7.6 ± 35.4 vs 1 ± 1.2 mg/L p < 0.001) compared with controls. Conclusion: Psoriasis patients show increased PWV, IMT, peripheral and central blood pressures, and serum cholesterol and C-reactive protein levels, denoting a higher cardiovascular risk.


Resumo Fundamento: A psoríase correlaciona-se a distúrbios metabólicos, ateromatose precoce e aumento do risco cardiovascular. Objetivos: Avaliar marcadores de doença cardiovascular na população psoriásica. Métodos: Estudo observacional transversal, envolvendo 11 participantes psoriásicos e 33 controles. Foram avaliados parâmetros antropométricos, laboratoriais, hemodinâmicos e de imagem. A rigidez arterial foi avaliada por oscilometria da artéria braquial. A espessura médio-intimal (EMI) e a função diastólica do ventrículo esquerdo foram avaliadas por meio da ecografia e ecocardiografia Doppler. As comparações de variáveis numéricas entre grupos foram realizadas por teste t-Student e Wilcoxon Mann-Whitney para amostras independentes, adotando-se o nível de significância de 5%. Resultados: Os pacientes psoriásicos apresentaram aumento de VOP (9,1 ± 1,8 e 8 ± 2 m/s, p = 0,033), EMI da artéria carótida comum esquerda (p = 0,018) e maior proporção de percentil > 75 pela tabela ELSA (54,5 e 18,2%, p = 0,045) e) quando comparados aos controles. Pacientes psoriásicos também mostraram aumento nos seguintes parâmetros em relação ao grupo controle, respectivamente: pressão arterial sistólica periférica/central (137,1 ± 13,2 e 122,3 ± 11,6 mmHg, p = 0,004)/(127 ± 13 e 112,5 ± 10,4 mmHg, p = 0,005), pressão arterial diastólica periférica/central (89,9 ± 8,9 e 82,2 ± 8 mmHg, p = 0,022) / (91 ± 9,3 e 82,2 ± 8,3 mmHg, p = 0,014), colesterol total (252 ± 43,5 e 198 ± 39,8 mg/dL, p < 0,001), colesterol LDL (167 ± 24 e 118 ± 40,8 mg/dL, p < 0,001) e proteína C reativa (7,6 ± 35,4 e 1 ± 1,2 mg/L, p<0,001). Conclusão: Pacientes psoriásicos apresentam elevações de VOP e EMI, além de maiores pressões arteriais periféricas e centrais, níveis séricos de colesterol e de proteína C reativa, denotando maior risco cardiovascular.


Subject(s)
Humans , Male , Adult , Middle Aged , Aged , Psoriasis/complications , Psoriasis/physiopathology , Cardiovascular Diseases/etiology , Cardiovascular Diseases/physiopathology , Oscillometry/methods , Reference Values , Severity of Illness Index , Blood Pressure/physiology , Brachial Artery/physiopathology , C-Reactive Protein/analysis , Echocardiography, Doppler , Case-Control Studies , Cholesterol/blood , Cross-Sectional Studies , Risk Factors , Statistics, Nonparametric , Risk Assessment , Carotid Intima-Media Thickness , Vascular Stiffness , Pulse Wave Analysis
12.
J. bras. pneumol ; 45(5): e20180311, 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1040280

ABSTRACT

RESUMO Objetivo avaliar os diferentes componentes da resistência do sistema respiratório e a força muscular respiratória, bem como investigar a ocorrência de limitação de fluxo expiratório (LFE) de pacientes obesos mórbidos (OM) na posição sentada. Métodos a amostra foi composta de OM (IMC ≥ 40 kg/m2) e de indivíduos não obesos (NO) com IMC entre 18 e 30 kg/m2. O protocolo foi composto de: avaliação antropométrica e da função respiratória (espirometria, pressões inspiratória (PIM) e expiratória máximas (PEM) e oscilometria de impulso). Na comparação entre os grupos, foi utilizado o teste T para amostras não pareadas. As correlações foram avaliadas pelo teste de Pearson, e o nível de significância foi de 5%. Resultados Foram avaliados 50 OM (idade 40,0 ± 10,4 anos, 1,64 ± 0,09 m, 138,8 ± 33,6 kg e 50,7 ± 8,9 kg/m2), além de 30 NO (idade 37,6 ± 11,5 anos, 1,67 ± 0,09 m, 65,2 ± 10,3 kg e 23,2 ± 22 kg/m2). Os OM apresentaram maiores valores de resistência total, central, de vias aéreas, tecidual e periférica quando comparados aos NO. Nenhum paciente apresentou LFE. A circunferência abdominal se associou com variáveis espirométricas PIM e PEM. A relação cintura-quadril se correlacionou com variáveis de mecânica respiratória, além das espirométricas PIM e PEM. Conclusões pacientes com obesidade mórbida e sem padrão espirométrico obstrutivo apresentam aumento nas resistências total, de vias aéreas, periférica e tecidual do sistema respiratório quando comparados a não obesos. Esses indivíduos, entretanto, não apresentam limitação de fluxo expiratório e redução da força muscular respiratória.


ABSTRACT Objective To evaluate the different components of the resistance of the respiratory system, respiratory muscle strength and to investigate the occurrence of expiratory flow limitation (EFL) in patients with morbid obesity (MO) when seated. Methods The sample was composed of MO (BMI≥40 kg/m2) and non-obese individuals (NO) with a BMI between 18 and 30 kg/m2. The protocol consisted of the anthropometric assessment and the following measures of respiratory function: spirometry, maximal inspiratory and expiratory pressures (MIP and MEP, respectively) and impulse oscillometry. The group comparison was performed using T-test for unpaired samples. The correlations were evaluated by the Pearson test with a significance level of 5%. Results Fifty MO (age 40±10.4 years, 1.64±0.09 m, 138.8±33.6 kg and 50.7±8.9 kg/m2), and 30 NO (age 37.6±11.5 years, 1.67±0.09 m, 65.2±10.3 kg and 23.2±22 kg/m2) were evaluated. The MO showed higher values of total, peripheral, airways, tissue and central resistance when compared to the NO. No patient showed EFL. The waist circumference was associated with spirometric variables, MIP, and MEP. The waist-to-hip ratio was correlated to respiratory mechanics and spirometric variables, MIP, and MEP. Conclusion Morbidly obese patients with no obstructive spirometric pattern show increased total, airway, peripheral, and tissue respiratory system resistance when compared to nonobese. These individuals, however, do not present with expiratory flow limitation and reduced respiratory muscles strength.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Obesity, Morbid/physiopathology , Respiratory Muscles/physiopathology , Respiratory Mechanics/physiology , Muscle Strength/physiology , Reference Values , Respiratory Function Tests , Case-Control Studies , Anthropometry , Cross-Sectional Studies , Statistics, Nonparametric , Exhalation/physiology
13.
Rev. Paul. Pediatr. (Ed. Port., Online) ; 36(4): 474-481, out.-dez. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-977084

ABSTRACT

RESUMO Objetivo: Verificar as repercussões do teste de esforço submáximo na mecânica respiratória e na função pulmonar de escolares. Métodos: Estudo transversal com escolares de 7 a 14 anos submetidos à avaliação da mecânica respiratória por sistema de oscilometria de impulso (IOS) e da função pulmonar pela espirometria. Realizou-se também o teste de caminhada de seis minutos (TC6), todos segundo os padrões da Sociedade Torácica Americana. O TC6 foi executado duas vezes com intervalo de 30 minutos entre cada teste. O IOS e a espirometria foram feitos antes do primeiro TC6 (pré-TC6) e repetidos imediatamente após o primeiro TC6 (pós-TC61) e após o segundo TC6 (pós-TC62). A comparação dos resultados nos três tempos do estudo se deu por análise de variância para medidas repetidas (teste post-hoc de Bonferroni) ou teste de Friedman, sendo significante p≤0,05. Resultados: Participaram 21 sujeitos; 53% masculinos e idade média de 10,9±2,3 anos. Encontraram-se diferenças entre resistência total (R5) e resistência central das vias aéreas (R20) nos 3 tempos do estudo (p=0,025 e p=0,041, respectivamente). A análise post-hoc indicou aumento de resistência R5 entre pré-TC6 e pós-TC61 (R5=0,540±0,100 versus 0,590±0,150 kPa/L/s, p=0,013; e R20=0,440±0,800 versus 0,470±0,100 kPa/L/s, p=0,038). A única variável espirométrica com alteração no decorrer do tempo foi o fluxo expiratório forçado 25-75% (FEF25-75%) (p=0,003). Conclusões: As repercussões encontradas foram: aumento da resistência total e da resistência central das vias aéreas e redução do FEF25-75% após o TC6 em escolares, sugerindo a necessidade de mais atenção na realização de testes submáximos em crianças com alguma predisposição a alterações das vias aéreas.


ABSTRACT Objective: To verify repercussions of submaximal exercise testing on respiratory mechanics and pulmonary function in schoolchildren. Methods: Cross-sectional study, with children aged 7 to 14 years, who had their respiratory mechanics assessed by impulse oscillometry (IOS), and pulmonary function by spirometry. They performed the six-minute walk test (6MWT), as per the standards by the American Thoracic Society. The 6MWT was performed twice with a 30-minute interval. IOS and spirometry were performed before the first 6MWT (Pre-6MWT) and immediately after the first (Post-6MWT1) and second walking tests (Post-6MWT2). The results in these three phases were compared by analysis of variance for repeated measures (post-hoc Bonferroni test) or by the Friedman's test, with p≤0.05 considered significant. Results: Twenty-one subjects participated in the study: 53% were males and mean age was 10.9±2.3 years. There were differences between total resistance (R5) and central airway resistance (R20) at the three phases of assessment (p=0.025 and p=0.041, respectively). Post-hoc analysis indicated increase in R5 when Pre-6MWT and Post-6MWT1 were compared (R5=0.540±0.100 versus 0.590±0.150 kPa/L/s, p=0.013; and R20=0.440±0.800 versus 0.470±0.100 kPa/L/s, p=0.038). Forced expiratory flow 25-75% (FEF25-75%) changed over time (p=0.003). Conclusions: Repercussions were: increase in central and total airway resistance and reduction of FEF25-75% after 6MWT in schoolchildren, suggesting that greater attention should be given to submaximal tests in children with predisposition to airways alterations.


Subject(s)
Humans , Male , Female , Child , Adolescent , Spirometry , Chest Wall Oscillation , Walk Test/methods , Lung/physiopathology , Time Factors , Cross-Sectional Studies
14.
J. pediatr. (Rio J.) ; 94(4): 419-424, July-Aug. 2018. tab
Article in English | LILACS | ID: biblio-954632

ABSTRACT

Abstract Objective: To compare impulse oscillometry system parameters of normal-weight children with overweight and obese children. Method: All participants were submitted to the evaluation of lung function (spirometry and impulse oscillometry) following the American Thoracic Society standards. The evaluation of respiratory mechanics was performed using the Jaeger™ MasterScreen™ Impulse Oscillometry System (Erich Jaeger, Germany), three tests were recorded, with acquisition for at least 20 seconds. Results: The study included 81 children (30 in the control group, 21 in the overweight group, and 30 the in obesity group), matched for age and sex. Regarding spirometry data, obesity group showed higher numerical values in relation to the control group; however, there were no significant differences among the three groups. For impulse oscillometry parameters, there was a difference between control group and obesity group for respiratory impedance (p = 0.036), resistance at 5 hertz (p = 0.026), resonant frequency (p = 0.029), and reactance area (p = 0.014). For the parameters expressed in percentage of predicted, there were differences in resistance at 5 hertz, resonant frequency, and reactance area between control group and obesity group. Conclusions: Obese children showed increased oscillometry parameters values representative of airway obstruction, compared to normal-weight children. Changes in some oscillometry parameters can already be observed in overweight school-aged children.


Resumo Objetivo: Comparar parâmetros do Sistema de Oscilometria de Impulso de crianças com peso normal com crianças com sobrepeso e obesas. Método: Todos os participantes foram submetidos à avaliação de mecanismos respiratórios utilizando o Sistema de Oscilometria de Impulso Jaeger™ (MasterScreen™ IOS, Erich Jaeger, Alemanha) seguindo as normas da Sociedade Torácica Americana. Todos os participantes foram submetidos a testes de espirometria e oscilometria (três testes foram registrados, com coleta de dados por pelo menos 20 segundos). Resultados: O estudo incluiu 81 crianças (30 no grupo de controle, 21 no grupo sobrepeso e 30 no grupo obesidade), pareadas por idade e sexo. No que diz respeito a dados de espirometria, o grupo obesidade mostrou valores numéricos mais elevados; contudo, não houve diferenças significativas entre os três grupos. No que diz respeito a parâmetros do Sistema de Oscilometria de Impulso, houve diferença entre o grupo de controle e o grupo obesidade em Z5 (p = 0,036), resistência 5 hertz (p = 0,026), frequência de ressonância (p = 0,029) e área de reatância (p = 0,014). Nos parâmetros expressos em percentual previsto, houve diferenças em resistência 5 hertz, frequência de ressonância e área de reatância entre o grupo de controle e grupo obesidade. Conclusões: Crianças obesas mostraram parâmetros de oscilometria aumentados representativos de obstrução das vias aéreas em comparação a crianças com peso normal. As alterações em alguns parâmetros oscilométricos já podem ser observadas em crianças com sobrepeso em idade escolar.


Subject(s)
Humans , Male , Female , Child , Adolescent , Oscillometry/methods , Respiratory Mechanics/physiology , Airway Resistance/physiology , Obesity/physiopathology , Spirometry , Case-Control Studies , Overweight/physiopathology
15.
Rev. sanid. mil ; 72(2): 90-97, mar.-abr. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-991626

ABSTRACT

Resumen Introducción La oscilometría de impulso es una prueba que evalúa la mecánica respiratoria a través de la aplicación de pequeños pulsos de presión que producen oscilaciones de flujo a una frecuencia determinada. Su aplicación relevante es en el estudio de las enfermedades de la vía aérea pequeña. El software integrado al equipo que ejecuta esta prueba genera cálculos de valores predictivos para cada uno de los parámetros oscilométricos, los cuales se basan en datos de población alemana. Objetivo Estandarizar la prueba de oscilometría de impulso y obtener ecuaciones piloto para valores de referencia. Material y métodos Se realizó un estudio experimental, analítico, prospectivo y longitudinal con sujetos voluntarios sanos. Se llevaron a cabo pruebas de espirometría y oscilometría de impulso basales y, tras broncodilatador, se registraron las impedancias, resistencias y reactancias del sistema respiratorio a 5, 10, 15 y 20 Hz. Los resultados se analizaron por sexo, edad, talla y peso. Se de 127 participantes sanos ingresaron al estudio, 51.5% del sexo efectuó un modelo de regresión lineal múltiple. Resultados Un total masculino (68) y 48.5% (64) del femenino, con edad promedio de 39.65 ± 15.26 años; la talla tuvo un promedio de 1.63 ± 0.09 m. Se demostró que el sexo influye en los valores de la oscilometría en el volumen corriente (VT), la impedancia, las resistencias y el área de reactancia (p < 0.05), y no afecta las reactancias (XRs) (p > 0.05); este parámetro está mayormente asociado a la talla (r = 0.727, r2 = 0.528). La edad incide en los valores de la oscilometría, ya que las resistencias (Rrs) son menores en los grupos más jóvenes; el IMC y el peso no comprometieron los valores de IOS. Conclusiones Este estudio proporciona ecuaciones piloto de referencia para los índices comunes de oscilometría de impulso en sujetos mexicanos. Así, integra una prueba de función pulmonar para facilitar la detección de alteraciones funcionales en vía aérea pequeña. Sugerimos realizar más trabajos en población mexicana, sobre todo de edad avanzada, para confirmar nuestros resultados y proporcionar una base más sólida a las ecuaciones de referencia para IOS, con un fin clínico y epidemiológico.


Abstract Introduction Impulse oscillometry is a test that evaluates the respiratory mechanics by the application of small pulses of pressure, which produce flow oscillations to a certain frequency. Its main application is in the study of the illnesses of the small airline. The integrated software of the test equipment generates predictive values for each of the oscillometric parameters, based on German population data. Objective To standardize the impulse oscillometry test in order to design pilot equations for reference values in our population. Material and methods We performed a pilot, experimental, analytical, longitudinal study with healthy volunteer subjects. Spirometry and impulse oscillometry tests were performed, both basal impedances, resistances, and reactances of the respiratory system to and after bronchodilator application; we measured and registered the 5, 10, 15, and 20 Hz. The results were analyzed by sex, age, height, and weight. The analysis was performed using a model of multiple linear retrogression. Results A total of 127 healthy participants were recruited, 51.5% men (68) and 48.5% (64) women, with an average age of 39.65 ± 15.26 years; their height was an average of 1.63 ± 0.09 m. It was proved that the gender influences the oscillometry values of tidal volume (VT), the impedance, the resistances and reactance area (p < 0.05), but not the reactances (XRs) (p > 0.05); this parameter is mainly associated with the size (r = 0.727, r2 = 0.528). The age influences the oscillometry values since the resistances (Rrs) are lower in the youngest groups; the BMI and the weight had no influence on the values of IOS. Conclusions This study provides pilot reference equations for the common indexes of impulse oscillometry in Mexican subjects, in order to integrate this test of pulmonary function to facilitate the detection of functional alterations in the small airline. We suggest more studies should be done on Mexican population, and especially on people of advanced age, to confirm our results and to provide a more solid base for the equations of reference to IOS, with clinical and epidemiologic purposes.

16.
Neumol. pediátr. (En línea) ; 12(4): 187-193, oct. 2017. graf, tab
Article in Spanish | LILACS | ID: biblio-999185

ABSTRACT

Impulse oscillometry (IOS) is an emerging tool in the study of pulmonary function in respiratory diseases. In this review we compare its usefulness with that of forced spirometry in children. Although these techniques measure different mechanical properties of the respiratory system, -the first, resistance, and the second, flow- they are, undoubtedly, complementary tests.. This review includes a brief description of some comparative studies since 1973, year of the first publication about children; then, with the advent of technology, its application in the mid-80s and 90s made it possible to include reference values in order to establish functional diagnoses. IOS measures airway, pulmonary and thoracic resistance, which is a primary function of the mechanics of ventilation, whereas spirometry measures the flow, which is a secondary function. This principle allows us to understand why IOS indices are more sensitive than those of spirometry


La Oscilometría de Impulso (IOS) es una herramienta emergente en el estudio de la función pulmonar y en esta revisión se compara su utilidad con la espirometría forzada en niños. Aunque ambas técnicas miden diferentes propiedades mecánicas del sistema respiratorio, resistencias la primera y flujos la segunda, tienen un carácter complementario incuestionable. Esta revisión describe brevemente algunos trabajos comparativos a partir de 1973, fecha de la primera publicación en niños y luego con el advenimiento tecnológico, su aplicación a mediados de los 80 y 90 permite incluir valores de referencia para poder establecer diagnósticos funcionales. La IOS se caracteriza por medir resistencia de la vía aérea y toracopulmonar y que desde el punto de vista de la mecánica respiratoria ésta es una función primaria versus los flujos, medidos por espirometría, que son una función secundaria, este principio es el que permite entender porque sus índices son más sensibles que los de la espirometría


Subject(s)
Humans , Child , Oscillometry/methods , Respiratory Tract Diseases/diagnosis , Spirometry/methods , Respiratory Function Tests/methods , Respiratory Tract Diseases/physiopathology , Vital Capacity , Airway Resistance , Forced Expiratory Volume
17.
Campinas; s.n; 2017. 114 p. ilus, tab.
Thesis in Portuguese | LILACS | ID: biblio-909436

ABSTRACT

Introdução: O sistema de oscilometria de impulso (IOS) é uma ferramenta de avaliação da função pulmonar, particularmente da mecânica respiratória. Envolve, em suas mensurações, parâmetros de resistência e reatância das vias aéreas, a partir de múltiplas frequências de 5 a 35 hertz, o que permite a diferenciação do comportamento dos parâmetros nas estruturas do sistema respiratório. Objetivos: Apresentar e discutir três estudos relacionados a função pulmonar avaliada pelo IOS e espirometria, em três situações distintas, em crianças e adolescentes: 1) com obesidade, 2) com exposição passiva ao tabagismo e 3) submetidas ao teste de caminhada de seis minutos (TC6). Método: Os estudos apresentados são de caráter comparativo, observacional, de corte transversal. Verificaram-se variáveis antropométricas (peso e altura) e aplicação do questionário Internacional de Asma e Alergias na Infância (ISAAC). Realizaram-se avaliações da função pulmonar por meio do IOS e da espirometria em crianças e adolescentes nos três estudos, com grupo de indivíduos saudáveis; estudo 1 (com sobrepeso e obesidade); estudo 2 (com relato de exposição passiva ao tabagismo); e estudo 3 (avaliações pré e pós o TC6). Resultados: No estudo 1, sobre obesidade, encontrou-se aumento dos valores dos parâmetros de IOS, representativos de obstrução das vias aéreas, em crianças obesas. O estudo 2, acerca da exposição ao tabagismo passivo, revelou que o IOS foi capaz de identificar mudanças iniciais relacionados à parâmetros da mecânica respiratória, relacionado a indicadores de presença de obstrução periférica e central das vias aéreas. No estudo 3, com o TC6, identificou-se aumento das resistências das vias aéreas (total e central), e diminuição significativa do fluxo expiratório forçado entre 25% e 75% da capacidade vital forçada (FEF25-75%) após o primeiro teste. Conclusões: O IOS demonstrou alterações significativas nas três situações estudadas. Este fato mostra que a busca de instrumentos e de marcadores para avaliar a função pulmonar deve continuar em situações fisiológicas e de doenças do trato respiratório. Esforços nessa área poderão contribuir para melhor esclarecimento e entendimento da deterioração da função pulmonar ao longo da vida de pessoas saudáveis e com doenças pulmonares crônicas.(AU)


Introduction: The impulse oscillometry (IOS) system is a tool to evaluate pulmonary function, particularly respiratory mechanics. It involves, in its measurements, airway resistance and reactance parameters, from multiple frequencies of 5 to 35 hertz, which allows the differentiation of the behavior of the parameters in the structures of the respiratory system. Objectives: To present and discuss three studies related to pulmonary function assessed by IOS and spirometry, in three different situations, in children and adolescents: 1) with obesity, 2) with passive exposure to smoking, and 3) submitted to six-minute walk test (6MWT). Method: The studies presented are comparative, observational, and cross-sectional. There were anthropometric variables (weight and height) and application of the International Questionnaire of Asthma and Allergies in Childhood (ISAAC). Evaluations of pulmonary function were performed through IOS and spirometry in children and adolescents in the three studies, with a group of healthy subjects; study 1 (overweight and obese); study 2 (with report of passive exposure to smoking); and study 3 (evaluation pre and post 6MWT). Results: In study 1, on obesity, it was found increase in IOS parameters, representative of airway obstruction, in obese children. Study 2, on exposure to passive smoking, revealed that IOS was able to identify initial changes in parameters of respiratory mechanics, and related to indicators of presence of peripheral and central airway obstruction. In the study 3, with 6MWT, identified increase in airway resistance (total and central), and significant decrease of forced expiratory flow between 25% and 75% of forced vital capacity (FEF25-75%) after the first test. Conclusions: IOS demonstrated significant alterations in the three situations studied. This fact demonstrates that the search for instruments and markers to evaluate pulmonary function should continue in physiological situations and diseases of the respiratory tract. Efforts in this area may contribute to a better enlightenment and understanding of the deterioration of pulmonary function during the life of healthy people with chronic lung diseases.(AU)


Subject(s)
Humans , Male , Female , Child , Adolescent , Adolescent , Child , Oscillometry , Tobacco Smoke Pollution , Exercise Test , Obesity , Obesity/complications , Oscillometry/methods , Respiratory Function Tests , Spirometry , Walk Test , Walk Test/methods
18.
Ces med. vet. zootec ; 11(2): 61-72, jul.-dic. 2016. tab
Article in English | LILACS | ID: biblio-952540

ABSTRACT

Abstract Background: most studies about Degenerative Mitral Valve Disease (DMVD) in dogs have focused on studying the echocardiographic (ECG) changes without considering changes in systolic, diastolic or mean blood pressure. Objective: to relate echocardiographic alterations and systemic pressure with the clinical stage in patients with DMVD. Methods: a random sample of 23 dogs with DMVD was obtained. A clinical classification of patients was performed based on criteria of the ACVIM. Blood pressure was taken with high-definition oscillometry equipment (HDO-2112-Vet) and then, patients underwent echocardiographic examination. Ultrasonographic features of the valve apparatus were assessed qualitatively, specifically the presence of thickening and prolapse of leaflets and remodelative changes, heart rate (HR), left atrium and aorta ratio (LA/AO), fractional shortening (FS), trans-valvular flows and pressure gradients were calculated as well. The confidence level was set at 95%. An univariate analysis was employed, as well as an ANOVA followed by a Fisher's test; Pearson's correlation was applied. Results: in the echocardiographic evaluation, statistically significant differences were observed between stages B1, B2 and C for the variables LA/AO, FS, and mitral gradient. There was a direct correlation between FS and mitral gradient (r= 0.66), LA/AO and mitral gradient (r= 0.70), and LA/AO and FS, (r= 0.75). An inverse correlation was found between systolic arterial pressure and FS (r= 0.51). Conclusions: patients with EDVM on stage C tended to have lower values tension; therefore, clinical evaluation with repeated blood pressure measurements in the same patient can help in decision-making and classification of the disease process. Among echocardiographic variables, the FS and LA/AO ratio were directly related to the clinical stage of the DMVD


Resumen Antecedentes: la mayoría de estudios sobre la Enfermedad Degenerativa de la Válvula Mitral (EDVM) en caninos se han enfocado en estudiar los cambios ecocardiográficos (ECG) sin considerar los cambios en la presión arterial sistólica, diastólica o media. Objetivo: relacionar las alteraciones ecocardiográficas y de presión sistémica con el estadio clínico en pacientes con EDVM. Métodos: se obtuvo una muestra al azar de 23 caninos con EDVM. Se realizó la clasificación del paciente según los criterios de la ACVIM. Se tomó la presión arterial con un equipo de oscilometría de alta definición (Vet-HDO-2112). Las características ultrasonográficas del aparato valvular fueron evaluadas cualitativamente, específicamente la presencia de engrosamiento y prolapso de valvas y los cambios remodelativos, la frecuencia cardíaca (FC), la relación AI/AO, la fracción de acortamiento, los flujos trans-valvulares y se calcularon los gradientes de presión. El nivel de confianza establecido fue del 95%. Se realizó un análisis univariado, prueba de ANOVA y el test de Fisher y se aplicó la correlación de Pearson. Resultados: en la evaluación ecocardiográfica se observó diferencia estadística significativa entre los estadios B1, B2 y C para las variables AI/AO, FA y gradiente mitral, una correlación directa entre FA y gradiente mitral (r= 0,66), AI/AO y gradiente mitral (r= 0,70), y entre AI/AO con FA (r= 0,75), y una correlación inversa entre la presión arterial sistólica y FA (r= 0,51). Conclusión: los pacientes con EDVM en estadio C mostraron tendencia a presentar valores más bajos de presión arterial, por ende, la evaluación clínica con mediciones repetidas de la presión arterial en el mismo paciente puede ayudar en la toma de decisiones y en la clasificación del proceso mórbido. Entre las variables ecocardiográficas, la FA y la relación AI/AO se relacionaron de manera directa con el estadio clínico de EDVM.


Resumo Antecedentes: a maioria dos estudos sobre a Doença Degenerativa da Valva Mitral (EDVM) em c ães têm sido foco em estudar alterações no ECG, independentemente de alterações na press ão arterial sistólica, press ão arterial diastólica ou média. Objetivo: relacionar ecocardiográfica e press ão sistêmica e estágio clínico em pacientes com EDVM. Métodos: foi obtida uma amostra aleatória de 23 c ães com EDVM. Houve um exame clínico seguido de classificação clínica de um paciente com base nos critérios do American College of Veterinary Internal Medicine (ACVIM). A press ão arterial foi tirada com uma Oscillometry alta definição automática (HDO-2112-Vet). Os pacientes foram submetidos a exame ecocardiográfico. Ele foi avaliado qualitativamente características ultra-sonográficos do aparelho valvar, específicamente a Presença de espessamento e / ou prolapso de folhetos e mudanças remodelative, HR, relação AE/AO, fração de encurtamento (FE), os fluxos trans-valvar e press ão, em seguida, calculou-se gradientes. O nível de confiança foi de 95% em setembro. Foi realizada análise de variância, seguida pelo teste de Fisher, correlação de Pearson foi aplicado. Resultados: a avaliação ecocardiográfica, foi observada diferença estatisticamente significativa entre as fases B1, B2 e C para as variáveis AI/AO, FE e gradiente mitral. Houve uma correlação direta entre a % de Gordura e gradiente mitral (r= 0,66), AI/AO e gradiente mitral (r= 0,70), e entre AI / AO com de gordura (r= 0,75) e uma correlação inversa entre a Press ão Arterial Sistólica e FE (r= 0,51). Conclusões: pacientes com EDVM fase em C eles tendem a ter valores tens ão, portanto, avaliação clínica com medições de press ão arterial repetidas no mesmo paciente pode ajudar na tomada de decisões e classificação do processo da doença. Entre as variáveis ecocardiográficas, FE e relação AI/AO estavam directamente relacionados com o estágio clínico da EDVM.

19.
Campinas; s.n; Jul. 2016. 105 p ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-848516

ABSTRACT

A mortalidade cardiovascular aumenta com a elevação da pressão arterial; sua aferição deve ser precisa e pode ser feita com aparelhos manuais ou automáticos. Estes equipamentos têm seu uso difundido por serem de fácil manuseio e custo acessível. Em decorrência da tecnologia da oscilometria, conceitos devem ser compreendidos e divulgados, entre eles a validação, realizada por meio de protocolos. Diretrizes americanas, brasileiras e outros autores apontam limitações na utilização do método oscilométrico, devido a alterações nos valores pressóricos que podem ser influenciados por rigidez arterial e arritmia cardíaca. Objetivos: Comparar valores de pressão arterial obtidos por dois aparelhos oscilométricos (um detecta arritmia cardíaca, outro não) àqueles obtidos com esfigmomanômetro de mercúrio; descrever o desempenho destes aparelhos. Método: A amostra por conveniência foi composta por 101 voluntários (51 homens e 50 mulheres; 52 com fibrilação atrial e 49 com ritmo cardíaco sinusal) e cada um foi submetido a oito aferições da pressão arterial em ambos os braços. Foram realizadas 808 aferições da pressão arterial, 404 utilizando o método auscultatório concomitantemente por dois observadores, com manômetro de mercúrio, e mais 404 utilizando o método oscilométrico por outro observador. Para medida oscilométrica utilizou-se dois esfigmomanômetros automáticos e para auscultatório um manômetro de mercúrio. Os dados foram coletados por uma equipe de quatro profissionais de saúde devidamente capacitados. Resultados: A coleta de dados ocorreu entre novembro de 2014 e agosto de 2015. Dos 101 participantes, 52 apresentavam fibrilação atrial e 49 ritmo cardíaco sinusal. A média de idade foi 69,57 anos. A circunferência de braço variou entre 21,50 e 41,00 cm. O esfigmomanômetro com recurso de detecção de arritmia cardíaca não exibiu esse sinal em 46,2% das medidas, no entanto houve associação significante entre a aparição deste sinal e o pulso apical irregular, auscultado no início do procedimento. Houve 26 ocorrências de duas tentativas de insuflação, sendo 18 pelo aparelho que detecta arritmia cardíaca e oito com o que não detecta. A concordância entre observadores atingiu um nível adequado. Conclusão: Ambos aparelhos automáticos apresentaram, de modo global, bom desempenho na amostra estudada, o que não diminui a necessidade de submetê-los a estudo de validação em indivíduos com ritmo cardíaco irregular.(AU)


Cardiovascular mortality increases due to high blood pressure; its measurement must be accurate and manual or automatic devices can be used. Such devices have widespread use because they are easy to handle and affordable. Due to the oscillometric technology, concepts must be understood and disclosed, including validation performed by means of protocols. American and Brazilian guidelines, and other authors point out limitations in the use of the oscillometric method, due to changes in blood pressure values which may be influenced by arterial stiffness and cardiac arrhythmia. Objectives: To compare blood pressure values obtained by two oscillometric devices (one detects cardiac arrhythmia, the other does not) to those obtained with mercury sphygmomanometer; to describe the performance of these devices. Methods: This convenience sample consisted of 101 volunteers (51 men and 50 women, 52 with atrial fibrillation and 49 with sinus rhythm) each one was subjected to eight measurements of blood pressure in both arms. It were performed 808 blood pressure measurements, 404 using auscultation with mercury manometer by two observers simultaneously, and 404 using the oscillometric method by another observer. Two automatic sphygmomanometers were used for oscillometric measurement, a mercury manometer for the auscultation. Data were collected by a team of four properly trained health professionals. Results: Data collection took place from November 2014 to August 2015. There were 101 participants, 52 had atrial fibrillation and 49 had sinus rhythm. The average age was 69.57 years. The arm circumference ranged from 21.50 to 41.00 cm. The sphygmomanometer cardiac arrhythmia detector did not show that sign in 46.2% of measures, however there was a significant association between the appearance of this signal and the irregular apical pulse, auscultation at the beginning of the procedure. There were 26 times of two attempts to inflation, 18 by the device that detected cardiac arrhythmia and eight which did not. The agreement among observers reached an appropriate level. Conclusion: Both automatic devices showed, at large, good performance in the sample studied which does not diminish the need to subject them to validation study in patients with irregular heart rhythm.(AU)


Subject(s)
Humans , Male , Female , Arrhythmias, Cardiac , Arterial Pressure , Blood Pressure Determination , Arrhythmia, Sinus , Atrial Fibrillation , Heart Auscultation , Oscillometry , Sphygmomanometers
20.
Rev. mex. ing. bioméd ; 37(1): 49-61, ene.-abr. 2016. tab, graf
Article in English | LILACS-Express | LILACS | ID: lil-789473

ABSTRACT

Abstract The Impulse Oscillometry System (IOS) has been recognized as a useful diagnostic tool. Previous research by our group has shown that R5 (Resistance at 5 Hz), R5-R20 (frequency dependence of resistance), AX (the "Goldman Triangle") and the extended Resistor-Inductor-Capacitor (eRIC) model-derived parameter Cp (peripheral Compliance) are reliable measures that track respiratory system function. Here we determined the predictive equations from 112 asthmatic and non-asthmatic Anglo and Hispanic children data, that were previously classified into four groups: Normal, PSAI (Probable Small Airway Impairment), SAI (Small Airway Impairment), and Asthma by using regression analysis of IOS and eRIC model parameters as dependent variables regressed against age, height, and weight. Height showed the greatest correlation with IOS and eRIC model parameters and provided the most significant reference values for these measures in Anglo and Hispanic children. These values could serve as a useful framework for diagnosis, early interventions, and treatment of respiratory diseases in this population.


Resumen El Sistema de Oscilometría Impulsos (por sus siglas en Inglés: IOS) ha sido reconocido como una herramienta de diagnóstico útil. Investigaciones previas realizadas por nuestro grupo han demostrado que R5 (Resistencia a 5 Hz), R5-R20 (dependencia a la frecuencia de la resistencia), AX (el "Triángulo de Goldman") y el párametro Cp (Capacitancia periférica) derivado del modelo extendido Resistencia-inductor-condensador (eRIC) son medidas fiables que monitorean la función del sistema respiratorio. El presente estudio determina las ecuaciones de predicción de 112 niños Anglo e Hispanos asmáticos y no asmáticos, que previamente clasificados en cuatro grupos: Normal, PSAI (por su nombre en inglés: Probable daño en las vías aéreas menores), SAI (por su nombre en inglés: Daño en las vías aéreas menores), y Asma. Las ecuaciones de predicción se determinaron mediante análisis de regresión de parámetros del IOS y del modelo eRIC (variables dependientes) contra edad, estatura y peso. La estatura mostró la mejor correlación con los parámetros del IOS y del modelo eRIC, proporcionando los valores de referencia más significativos para estas medidas en niños Anglos e Hispanos. Estos valores podrían servir como un marco de referencia útil para el diagnóstico, intervenciones tempranas, y tratamiento de las enfermedades respiratorias en esta población.

SELECTION OF CITATIONS
SEARCH DETAIL