Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Braz. dent. sci ; 26(2): 1-11, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1436387

ABSTRACT

Objective: The rehabilitation choice for the edentulous patients usually lies between the fixed and removable prosthetic options. The treatment decisions are affected by many factors where complications and maintenance needs are both considered crucial factors, in addition to the cost effectiveness of the chosen treatment. Material and Methods: This study was applied on 44 edentulous patients, where 22 patient for each group were enrolled in the outpatient clinic of prosthodontics, Cairo University as per a set of eligibility criteria. Four inter-foraminal implants were installed for all eligible participants. Three months later, healing abutments were used for soft tissue preparation prior to the fabrication of the final prosthesis. A prosthetic treatment option was then randomly allocated to obtain two equal groups via computer generated randomization program; Group. A received telescopic implant overdentures, and Group. B received screw retained dentures. All Complications (Screw loosening or fracture, tooth or denture base fracture and mucositis) were reported after overdenture insertion along the follow up period (1, 6, 9 and 12 months respectively). Results: The frequency of the screw loosening for hybrid overdentures where (59.1%) compared to (27.3%) of telescopic prosthesis at 12 months follow up period (p=0.035), mucositis reporting at 6m interval had shown the highest frequency in both groups (Group A (54.5%), Group B (81.8%), (p=0.045), all other reported complications that lack statistical significance either within the same group or between both groups at different time intervals. Conclusion: Both treatment modalities; telescopic implant overdenture and hybrid fixed screw-retained are reliable for restoring the completely edentulous arches, the decision whether to make a fixed or removable implant denture shall be guided with the patient preference together with the dentist assessment in relation (AU)


Objetivo: A escolha da reabilitação para pacientes edêntulos geralmente recai entre próteses fixas e removíveis. As decisões de tratamento são afetadas por muitos fatores onde as complicações e as necessidades de manutenção são consideradas critérios cruciais, além do custo-efetividade do tratamento escolhido. Material e Métodos: Este estudo foi aplicado em 44 pacientes edêntulos, onde 22 pacientes para cada grupo foram matriculados no ambulatório de prótese dentária da Universidade do Cairo de acordo com um conjunto de critérios de elegibilidade. Quatro implantes interforaminais foram instalados para todos os participantes elegíveis. Três meses depois, pilares de cicatrização foram utilizados para preparação dos tecidos moles antes da fabricação da prótese final. Uma opção de tratamento protético foi então alocada aleatoriamente para obter dois grupos iguais por meio de andomização gerada através programa de computador. O Grupo A recebeu overdentures de implantes telescópicos e o Grupo B recebeu dentaduras fixas parafusadas sobre os implantes. Todas as complicações (afrouxamento ou fratura do parafuso, fratura da base do dente ou da prótese e mucosite) foram relatadas após a inserção da overdentures ao longo do período de acompanhamento (1, 6, 9 e 12 meses, respectivamente). Resultados: A frequência do afrouxamento do parafuso para Overdentures híbridas (59,1%) em comparação com (27,3%) da prótese telescópica no período de acompanhamento de 12 meses (p=0,035), o relato de mucosite no intervalo de 6 meses mostrou a maior frequência em ambos os grupos (Grupo A (54,5%), Grupo B (81,8%), p=0,045, todas as outras complicações relatadas foram sem significância estatística dentro do mesmo grupo ou entre os dois grupos em intervalos de tempo diferentes. Conclusão: Ambas as modalidades de tratamento; overdentures sobre implantes telescópicos e próteses híbridas fixas parafusadas são confiáveis para reabilitar as arcadas completamente edêntulas. A decisão de fazer uma prótese fixa ou removível sobre implantes deve ser guiada pela preferência do paciente juntamente com a avaliação do dentista em relação ao estado geral do paciente e sua saúde bucal. (AU)


Subject(s)
Humans , Dental Prosthesis Design , Dental Prosthesis , Dental Prosthesis, Implant-Supported , Denture, Overlay
2.
Rev. inf. cient ; 101(6)dic. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1441968

ABSTRACT

Introducción: El envejecimiento es un fenómeno presente a lo largo del ciclo vital, desde el mismo proceso de la concepción hasta la muerte, donde el uso de prótesis dental puede influir en la calidad de vida. Objetivo: Determinar la influencia del uso de prótesis dental en la calidad de vida de los adultos mayores de la clínica privada Dental C&S Luis Fernando Criollo, Esmeraldas, Ecuador. Método: Se realizó un estudio descriptivo transversal en 23 ancianos seleccionados mediante un muestreo no probabilístico. La recolección de la información se realió mediante una encuesta validada por expertos. Se analizó el uso de prótesis total, tiempo de su uso, problemas en la masticación, desajuste con facilidad y a qué lo atribuye, afección de la mucosa bucal por la masticación, tiempo en tomar los alimentos y características de estos. Resultados: Predominó del uso de prótesis total (62,5 %) con más de 2 años de uso (59,1 %). El 59,5 % refirió tener problemas en la masticación al usar las prótesis y que se les desajustaban con facilidad (54,5 %), atribuyen esto último al consumo de alimentos duros (50,0 %). Se encontró la presencia de lesiones en las encías en el 56,5 % de los encuestados, los que demoraban alrededor de 40 minutos en tomar sus comidas. Conclusiones: El uso de prótesis influye en la calidad de vida del adulto mayor al afectar la masticación, desajustarse la prótesis al ingerir alimentos duros, presentar lesiones en la mucosa bucal y utilizar más tiempo en la toma de sus alimentos.


Introduction: Aging is a phenomenon present throughout the life cycle, from the beginning to end of life, where the use of dental prostheses may have a great impact on the quality of life. Objective: To determine the influence of the use of dental prostheses on the quality of life of the older adult patients treated in the private dental clinic Dental C&S Dr. Luis Fernando Criollo, located in the city of Esmeraldas, Ecuador. Method: A cross-sectional descriptive study was carried out in 23 elderly people selected by non-probabilistic sampling. The information was collected by means of a survey validated by experts. It was analyzed the use of total prosthesis, time of use, chewing problems, easily misaligned and the causes, affectation of the buccal mucosa caused by chewing, time in taking food and its characteristics. Results: The use of total prosthesis was predominant (62.5%) in the adults studied and 59.1% of them referred have been using it for more than 2 years. The 59.5% reported chewing problems when using the prosthesis, 54.5% reported a frequent prosthesis misalignment, in which 50.0% of them reported the consumption of hard foods as main cause. The 56.5% of respondents was found with gums problem and they took approximately 40 minutes to eat their meals. Conclusions: The use of prostheses have a great impact on the quality of life of older adults, causing on them chewing problems and misalignment when eating hard foods, presenting lesions in the oral mucosa and taking more time to eat.


Introdução: O envelhecimento é um fenômeno presente em todo o ciclo vital, desde o próprio processo de concepção até a morte, onde o uso de próteses dentárias pode influenciar na qualidade de vida. Objetivo: Determinar a influência do uso de próteses dentárias na qualidade de vida dos idosos da clínica privada Dental C&S Luis Fernando Criollo, Esmeraldas, Equador. Método: Estudo transversal descritivo realizado em 23 idosos selecionados por amostragem não probabilística. A coleta de informações foi realizada por meio de uma pesquisa validada por especialistas. Foram analisados o uso de prótese total, tempo de uso, problemas mastigatórios, desalinhamento com facilidade e a que se atribui, acometimento da mucosa oral devido à mastigação, tempo gasto para se alimentar e suas características. Resultados: Predominou o uso de prótese total (62,5%) com mais de 2 anos de uso (59,1%). 59,5% relataram ter problemas de mastigação ao usar as próteses e que elas se desajustavam facilmente (54,5%), atribuem isso ao consumo de alimentos duros (50,0%). A presença de lesões gengivais foi constatada em 56,5% dos entrevistados, que demoravam em torno de 40 minutos para realizar suas refeições. Conclusões: O uso de prótese influencia na qualidade de vida do idoso por afetar a mastigação, desajustar a prótese ao ingerir alimentos duros, apresentar lesões na mucosa oral e passar mais tempo comendo.

3.
Rev. cienc. salud (Bogotá) ; 20(2): 1-15, 20220510.
Article in Spanish | LILACS, COLNAL | ID: biblio-1427178

ABSTRACT

Introducción: evaluar la satisfacción con los tratamientos requiere cuestionarios específicos y validados que garanticen una prestación del servicio adecuada y que contribuya al bienestar de las personas. El objetivo fue evaluar la validez y la confiabilidad de la versión colombiana de un cuestionario sobre satis-facción en una población de usuarios de prótesis total. Materiales y métodos: se realizó un estudio de evaluación de tecnología diagnóstica con una población de 226 pacientes, a partir de las características sociodemográficas y los diez ítems del instrumento. Se analizó la consistencia interna, la reproducibilidad prueba-reprueba y los límites de acuerdo de Bland y Altman. Así mismo, se analizaron los componentes y se aplicó el modelo de Rasch. Resultados: participaron 158 (69.91 %) mujeres y la mediana de edad fue de 69 años. Se obtuvieron un alfa de Cronbach de 0.90 y un coeficiente de correlación intraclase de 0.91. Se identificaron dos factores, los diez ítems se ajustaron al modelo de Rasch y no se observó un funcionamiento diferencial del ítem. Conclusiones: la versión colombiana del cuestionario presentó excelente confiabilidad y las medidas obtenidas explicaron el 58.60 % de la varianza.


Introduction: Evaluating treatment satisfaction requires a specific and validated questionnaire that can obtain information about adequate service provision and contribute to people's well-being. The objective of this study was to evaluate the validity and reliability of the Colombian version of a questionnaire on satisfaction among complete denture wearers. Materials and methods: This survey evaluated diagnostic technology used among 226 patients. Information on sociodemographic characteristics was obtained and ten items of the instrument were evaluated. Internal consistency, test-retest reproducibility, and Bland-Altman limits of agreement were analyzed. Component analysis was performed and the Rasch model was used. Results: Median age of the participants was 69 (ric: 63-76) years, and 158 (69.91%) were women. Cronbach's alpha and intraclass correlation coefficients were 0.91 and 0.80, respectively. Two factors were identified, all ten items conformed to the Rasch model and no differential item functioning was observed. Conclusions: The Colombian version of the questionnaire showed excellent reliability, and the proportion of variance explained by the measures was deemed satisfactory (58.60%).


Introdução: a avaliação da satisfação com os tratamentos requer questionários específicos e validados, que garantam uma prestação de serviço adequada e contribuam para o bem-estar das pessoas. O obje-tivo é avaliar a validade e confiabilidade da versão colombiana de um questionário de satisfação em uma população de usuários de próteses dentárias totais. Materiais e métodos: foi realizado um estudo de avaliação de tecnologia diagnóstica com uma população de 226 pacientes. Foram avaliadas as carac-terísticas sociodemográficas e os dez itens do instrumento. A consistência interna, a reprodutibilidade teste-reteste e os limites de concordância foram analisados de acordo com Bland e Altman. Foi reali-zada uma análise de componentes e aplicado o modelo Rasch. Resultados: participaram 158 (69,91%) mulheres, a mediana de idade foi de 69 anos. Obteve-se um alfa de Cronbach de 0,90 e um coeficiente de correlação intraclasse de 0,91. Dois fatores foram identificados, os dez itens se ajustaram ao modelo Rasch e nenhum funcionamento diferencial dos itens foi observado. Conclusões: A versão colombiana do questionário apresentou excelente confiabilidade e as medidas obtidas explicaram 58,60% da variância.


Subject(s)
Humans , Female , Middle Aged , Patients , Personal Satisfaction , Prostheses and Implants , Health Care Quality, Access, and Evaluation
4.
Rev. inf. cient ; 100(6)dic. 2021.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1409504

ABSTRACT

RESUMEN Introducción: Con el avance de la tecnología adhesiva, nuevas técnicas y materiales restauradores están siendo utilizados para el tratamiento de dientes endodonciados, por ello, las endocoronas son una alternativa clínica para su tratamiento. La ventaja de esta restauración es que tiene mejores características macro retentivas, requiere menor tiempo clínico y de laboratorio. Objetivo: Proporcionar información bibliográfica actual sobre esta nueva alternativa para aplicar una nueva guía en rehabilitación oral con el uso de la endocorona mediante una revisión de la literatura. Método: Se realizó una revisión bibliográfica detallada, con la consideración de artículos originales o casos clínicos que incluían información relacionada a las restauraciones de tipo endocorona. La búsqueda se efectuó en las bases de datos PubMed, SciELO, Science Direct, Elsevier y Google Académico. Resultados: Las restauraciones de tipo endocorona son un monobloque único que devuelve la anatomía completa de la corona dental, la cual aprovecha la cámara pulpar para así lograr una mayor adhesión y macro retención mecánica. Este enfoque restaurador proporciona una función adecuada y estética, así como la integridad biomecánica de las estructuras no vitales. Conclusiones: Actualmente en la Odontología moderna se emplea el término de mínima intervención, conservando en su mayor cantidad posible el tejido dental de manera que los dientes tengan mayor funcionalidad, por ello las endocoronas son una opción segura y con buen pronóstico a largo plazo en rehabilitación oral para tratar piezas endodonciadas, debido a que es un procedimiento técnicamente más conservador, estético, sencillo y de menor costo.


ABSTRACT Introduction: With the advancement of adhesive technology, new techniques and restorative materials are being used for the treatment of root canals; therefore endocrowns are a clinical alternative for their treatment. The advantage of this restoration is that it has better macro retentive characteristics, requires less clinical and laboratory time. Objective: To provide current bibliographic information on this new alternative to apply a new guide in oral rehabilitation with the use of endocrown through a literature review. Method: A detailed bibliographic review was carried out, with the consideration of original articles or clinical cases that included information related to endocrown-type restorations. The search was carried out in the databases PubMed, SciELO, Science Direct, Elsevier and Google Scholar. Results: Endocrown restorations are a single monoblock that rebuilds the complete anatomy of the dental crown, which takes advantage of the pulp chamber to achieve greater adhesion and macro mechanical retention. This restorative approach provides adequate function and aesthetics, as well as the biomechanical integrity of non-vital structures. Conclusions: The term minimal intervention is currently very used in modern dentistry, preserving the dental tissue as much as possible so that the teeth have greater functionality. Endocrowns are a safe option with a good long-term prognosis in oral rehabilitation to treat root canals, because it is a technically more conservative, aesthetic, simple and lower-cost procedure.


RESUMO Introdução: Com o avanço da tecnologia adesiva, novas técnicas e materiais restauradores estão sendo utilizados para o tratamento de dentes endodônticos, portanto os endocrowns são uma alternativa clínica para seu tratamento. A vantagem dessa restauração é que ela apresenta melhores características macro retentivas, requer menos tempo clínico e laboratorial. Objetivo: Fornecer informações bibliográficas atuais sobre esta nova alternativa de aplicação de um novo guia na reabilitação oral com o uso de endocrown por meio de uma revisão da literatura. Método: Foi realizada uma revisão bibliográfica detalhada, considerando artigos originais ou casos clínicos que incluíam informações relacionadas a restaurações do tipo endocrown. A busca foi realizada nas bases de dados PubMed, SciELO, Science Direct, Elsevier e Google Scholar. Resultados: As restaurações do tipo endocrown são um único monobloco que devolve a anatomia completa da coroa dentária, que aproveita a câmara pulpar para obter maior adesão e retenção macromecânica. Esta abordagem restauradora fornece função e estética adequadas, bem como a integridade biomecânica de estruturas não vitais. Conclusões: Atualmente na odontologia moderna é utilizado o termo de intervenção mínima, preservando-se o tecido dentário o máximo possível para que os dentes tenham maior funcionalidade, portanto endocrowns são uma opção segura e com bom prognóstico em longo prazo na reabilitação oral para tratamento da endodontia dentes, por ser um procedimento tecnicamente mais conservador, estético, simples e de menor custo.

5.
Rev. inf. cient ; 100(4): e3462, 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1289649

ABSTRACT

RESUMEN Introducción: Los pacientes geriátricos portadores de prótesis removible con frecuencia presentan lesiones paraprotésicas que repercuten en su calidad de vida. Objetivo: Identificar los tipos de lesiones paraprotésicas en pacientes geriátricos portadores de prótesis removibles. Método: Se realizó un estudio observacional y descriptivo en 97 pacientes de cualquier sexo, mayores de 60 años, portadores de prótesis removible, que acudieron a la Clínica Estomatológica Docente Provincial "Dr. Justo Ortelio Pestana Lorenzo" de Sancti Spíritus, por presentar algún tipo de lesión en la mucosa bucal, desde enero de 2019 hasta febrero de 2020. Se utilizaron métodos del nivel teórico, empírico y estadístico-matemático para el estudio de las variables: edad, sexo, tipo de lesión. Resultados: El 49,5 % del universo correspondió a pacientes de 60 a 69 años y el 66 % del sexo femenino. Las lesiones paraprotésicas más frecuentes fueron la estomatitis subprótesis (55,6 %) y las úlceras traumáticas (31,9 %). Conclusiones: Las lesiones de la mucosa bucal asociadas al uso de prótesis removible fueron más frecuentes en las mujeres. La estomatitis subprótesis fue la lesión paraprotésica que predominó, seguida de la úlcera traumática y épulis fisurado.


ABSTRACT Introduction: Geriatric patients with removable prostheses often present paraprosthetic lesions that have an unfavorable impact on their quality of life. Objective: To identify the type of paraprosthetic lesions in geriatric patients with removable prostheses. Method: An observational and descriptive study in a total of 97 patients with removable prostheses, no specific sex, and over 60 years of age, was carried out. All patients studied were presented to the Clínica Estomatológica Docente Provincial "Dr. Justo Ortelio Pestana Lorenzo" in Sancti Spíritus, from January 2019 throughout February 2020, with any type of oral lesions. Theoretical, empirical and statistical-mathematical methods were used to study the following variables: age, sex, type of lesions. Results: The 49.5% of the total of patients studied were 60 to 69 years old and 66% were female. Most common paraprosthetic lesions found were the subprosthetic stomatitis (55.6%) and traumatic ulcers (31.9%). Conclusions: The oral lesions related to removable prostheses were most common in females. The subprosthetic stomatitis was the most predominant followed by the traumatic ulcer and fissured epulis.


RESUMO Introdução: Pacientes geriátricos com próteses removíveis freqüentemente apresentam lesões paraprotéticas que afetam sua qualidade de vida. Objetivo: Identificar os tipos de lesões paraprotéticas em pacientes geriátricos com próteses removíveis. Método: Foi realizado um estudo observacional e descritivo em 97 pacientes de ambos os sexos, maiores de 60 anos, com próteses removíveis, atendidos na Clínica Provincial de Ensino de Estomatologia "Dr. Justo Ortelio Pestana Lorenzo "de Sancti Spíritus, por apresentar algum tipo de lesão na mucosa oral, de janeiro de 2019 a fevereiro de 2020. Foram utilizados métodos de nível teórico, empírico e estatístico-matemático para estudar as variáveis: idade, sexo, tipo de lesão. Resultados: 49,5% do universo corresponderam a pacientes de 60 a 69 anos e 66% ao sexo feminino. As lesões paraprotéticas mais frequentes foram estomatite subprotética (55,6%) e úlceras traumáticas (31,9%). Conclusões: As lesões da mucosa oral associadas ao uso de próteses removíveis foram mais frequentes nas mulheres. A estomatite subprotética foi a lesão paraprotética predominante, seguida por úlcera traumática e epúlide fissurada.


Subject(s)
Humans , Middle Aged , Aged , Aged, 80 and over , Stomatitis, Denture/etiology , Denture, Partial, Removable , Mouth Mucosa/injuries , Epidemiology, Descriptive , Observational Studies as Topic
6.
São José dos Campos; s.n; 2021. 75 p. ilus, graf, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1362274

ABSTRACT

Este estudo avaliou a resistência à fadiga cíclica de estruturas em forma de disco cerâmico multicamada de configuração tradicional (T) e bionispirado em macroescala (B), cimentadas de forma adesiva ao substrato analógo à dentina. As amostras foram produzidas com zircônia (Ø = 10 mm, espessura = 0,5 mm) e cerâmica feldspática (Ø = 10 mm, espessura = 1,5 mm) e foram unidas com três técnicas diferentes (n = 15): Injeção (inj); com vidro de fusão Crystal Connect (cv) e técnica cimentada (cim). Para a configuração tradicional a zircônia foi a infraestrura sobre qual a cerâmica feldspática foi aderida. Para os bioinspirados, a zircônia foi a supraestrutura e a cerâmica feldspática foi a infraestrutura. Os discos foram cimentados em resina G-10 (Ø = 10 mm, espessura = 1,5 mm). As amostras foram testadas sob a abordagem de fadiga cíclica até apresentar alguma trinca observada por transluminação. O método stepwise: 20 Hz, seguidos por etapas incrementais de 200 N a cada 10 x 103ciclos, com carga inicial de 600 N até 2600 N com pistão de 40 mm de diâmetro e célula de carga de 5 KN (Instron Electropuls E 3000, Instron, Glenview, IL, EUA). Todas as amostras foram analisadas estereomicroscópio para determinar o tipo de falha e uma amostra representativa de cada grupo foi analisada no microscópio eletrônico de varredura (MEV). As configurações bioinspiradas testadas foram estatisticamente semelhantes (p > 0,05) e não aumentaram a sobrevivência à fadiga das estruturas comparadas com a técnica tradicional. A bioinspiração apresentou predominantemente trincas radias e únicas. A gradação do modulo elástico em macroescala e a configuração das estruturas. A utilização do conector vítreo se mostro favorável para diminuir das trincas no material análogo á dentina.


This study evaluated the cyclic fatigue resistance of multilayer ceramic discshaped structures of traditional configuration (T) and macroscale bionispirate (B), cemented adhesively to the substrate analogic to dentin. The samples were produced with zirconia (Ø = 10 mm, thickness = 0.5 mm) and feldspar ceramics (Ø = 10 mm, thickness = 1.5 mm) and were joined with three different techniques (n = 15): Injection (inj); with Crystal Connect melting glass (cv) and cemented technique (Cim). For the traditional configuration zirconia was the infraestrura on which the feldspathic ceramic was adhered. For the bioinspired, zirconia was the superstructure, and feldspathic ceramics was the infrastructure. The discs were cemented in G-10 resin (Ø = 10 mm, thickness = 1.5 mm). The samples were tested under the cyclic fatigue approach until some crack was observed by translumination. The stepwise method: 20 Hz, followed by incremental steps of 200 N every 10 x 103 cycles, with initial charge from 600 N to 2600 N (40 mm diameter piston) and 5 KN load cell (Instron Electropuls E 3000, Instron, Glenview, IL, USA). All samples were analyzed stereomicroscopically to determine the type of failure and a representative sample of each group was analyzed in the scanning electron microscope (SEM). The bioinspired configurations tested were statistically similar (p > 0.05) and did not increase the fatigue survival of the structures compared to the traditional technique. The bioinspiration presented predominantly radial and unique cracks. The use of the vitreous connector was favorable to decrease the cracks in the analogous dentin material.


Subject(s)
Zirconium/chemistry , Dental Prosthesis , Dental Porcelain , Materials Testing , Microscopy, Electron, Scanning , Survival Analysis , Shear Strength
7.
J. Health Sci. Inst ; 37(4): 345-350, Oct-Dec 2019. tab
Article in Portuguese | LILACS | ID: biblio-1359246

ABSTRACT

Objetivos ­ À vista disso, conhecendo como a principal condição exógena para que ocorra a proliferação de Candida e introdução de Candidose em cavidade oral é a prótese dentária com tempo de uso de mais de 5 anos, propomos nesse estudo avaliar a quantificação de Candida na saliva pacientes usuários de prótese parcial e total removíveis, correlacionando com idade avançada e o fluxo salivar e fatores que possam agir influenciando sua quantificação. As espécies do gênero Candida são normalmente encontradas na microbiota de pacientes saudáveis, sendo a C. Albicans a mais comum. Já a patogenicidade da espécie só ocorre caso haja condições propicias para o seu desenvolvimento, como comprometimento do sistema imune, hiposalivação e uso incorreto de próteses. As próteses totais, em especial, estão associadas ao aumento de UFC e presença de candidose na cavidade oral. Métodos ­ Foram avaliados 121 indivíduos sendo 31 do grupo controle e 90 usuários de próteses dentárias. Foram realizada uma coleta de saliva de cada paciente no momento da primeira consulta odontológica e os pacientes foram classificados quanto ao fluxo salivar em reduzido, normal e aumentados. A análise microbiológica foi realizada com a mesma saliva utilizada na avaliação do fluxo salivar, sendo estas semeadas e a as colônias de Candida foram quantificadas e os pacientes serão categorizados em negativos, portadores e positivos. Resultados ­ Foi possível uma relação forte no que se refere a diminuição do fluxo salivar associado a idade avançada e em decorrência disto, com a quantidade de UFC de Candida na saliva dos pacientes estudados. Conclusão ­ Posto isso, fica comprovado que os pacientes que utilizam próteses removíveis são os com maior quantidade de UFC, seguidos pelos pacientes que utilizam próteses totais


Objectives ­ In view of this, knowing as the main exogenous condition for the occurrence of Candida proliferation and introduction of Candidosis in oral cavity is the dental prosthesis with time of use of more than 5 years, we propose in this study to carry out a evaluation the quantification of the presence of Candida in saliva in patients using partial and total removable prosthesis, correlating at the found with advanced age and the salivar flow and factors that may influence its quantification. Species of the genus Candida are usually found in the microbiota of healthy patients, with C. Albicans being the most universal. The pathogenicity of the species occurs only if there are propitious conditions to its development, such as impairment of the immune system, hyposalivation and incorrect use of prostheses. Total prostheses, in particular, are associated with increased CFU and the presence of candidosis in the oral cavity. Methods ­ A total of 121 individuals were evaluated, 31 from the control group and 90 users of dental prostheses. Saliva collection was performed from each patient at the time of the first dental appointment and the patients were classified as reduced, normal and increased salivary flow. Microbiological analysis was performed with the same saliva used for salivary flow evaluation. These were sown and Candida colonies were quantified and patients were categorized as negative, carrier and positive. Results ­ It was possible to have a strong relationship regarding the decrease in salivary flow associated with advanced age and, as a result, with the amount of Candida CFU in the saliva of the studied patients. Conclusion ­ Thus, it is proven that patients using removable prostheses are the ones with the highest amount of CFU, followed by patients using total prosthesis


Subject(s)
Humans , Male , Female , Candida , Candidiasis, Oral , Denture, Complete , Denture, Partial, Removable , Oral Hygiene , Fungi
8.
Braz. dent. sci ; 21(4): 377-385, 2018. ilus, tab
Article in English | LILACS, BBO | ID: biblio-965247

ABSTRACT

Objective: To evaluate the bond strength of different repair treatments for composite resin to aged Y-TZP ceramics. Material and Methods: Zirconia blocks were cut into smaller specimens, sintered according to manufacturer's recommendations (final dimensions of 4×4×3 mm), and randomly allocated into nine groups (n=15) according to the surface treatment and presence/ absence of aging of the substrate (subjected to lowtemperature degradation - LTD), as follows: without LTD (Control: without treatment; TBS: tribochemical silica coating + silane + adhesive); with LTD (Control-LTD: without treatment; TBS-LTD: TBS with hydrothermal degradation; MoS-LTD: Monobond S + adhesive; MoPLTD: Monobond Plus + adhesive; MZP-LTD: Metal/ Zirconia Primer + adhesive; USB-LTD: Single Bond Universal; AP-LTD: Alloy primer + adhesive). LTD was simulated in an autoclave (134 °C, 2 bar, 5 h). The ceramic blocks were embedded in PVC cylinders with a self-curing acrylic resin; each surface treatment protocol was performed; a composite resin cylinder ( : 3.25 mm and height: 3 mm) was then build-up using split metallic matrices. All the specimens were aged (thermocycling + storage in water for 90 days) and subjected to the shear bond strength test using a universal testing machine (1 mm/min). The failure mode was classified into four types: adhesive, composite resin cohesive fracture, ceramic cohesive fracture, and mixed. The bond strength values were subjected to Mann­Whitney test. Results: Only air-abraded samples (TBS and TBS­LTD) survived thermocycling. More than 80% of the samples of the other groups presented pre-test failures. TBS groups presented higher values of bond strength (3.94) compared to TBSLTD (0.96). The predominant type of failure for the surviving samples were adhesive. Conclusion: Air particle abrasion is mandatory to improve the bond strength of the Y-TZP substrate; an aged substrate presents an even more unfavorable scenario for adhesion. (AU)


Objetivo: Avaliar a resistência de união ao cisalhamento gerada por diferentes técnicas de reparo em resina composta aderida em zircônia envelhecida (sujeita a degradação a baixa temperatura - LTD). Material e Métodos: blocos de zircônia foram seccionados em espécimes, sinterizados de acordo com o fabricante (dimensões finais de 4x4x3 mm), e aleatorizados em nove grupos (n=15) de acordo com o tratamento de superfície e presença/ausência de envelhecimento do substrato (LTD), conforme: sem LTD (Control: sem tratamento; TBS: tribosilicatização + silano + adesivo); com LTD (Control-LTD: Monobond S + adesivo; MoP-LTD: Monobond plus + adesivo; MZPLTD: Meta/Zirconia primer + adesivo). LTD foi simulada em autoclave (134 °C, 2 bar, 5 h). Os blocos de cerâmica foram embutidos em cilindros de PVC com resina acrílica autopolimerizável; cada tratamento de superfície foi realizado; um cilindro de resina composta ( : 3,25 mm 3 mm de altura) foi confeccionado usando matrizes metálicas bipartidas. Todos os espécimes foram envelhecidos (termociclagem + armazenagem em água por 90 dias) e sujeitos ao teste de cisalhamento usando um equipamento de teste universal (1 mm/ min). O modo de falha foi classificado em quatro grupos: adesivo, fratura coesiva em resina composta, fratura coesiva da cerâmica, e mista. Os valores de adesão foram sujeitos ao teste de Mann-Whitney. Resultados: somente as amostras jateadas (TBS e TBSLTD) sobreviveram a termociclagem. Mais que 80% dos espécimes dos outros grupos apresentaram falhas préteste. Os grupos TBS apresentaram os maiores valores de resistência ao cisalhamento (3,94) comparado com TBS-LTD (0,96). Os tipos predominantes de falha para os espécimes sobreviventes foi adesiva. Conclusão: o jateamento é recomendável para aumentar a resistência adesiva à zircônia; um substrato envelhecido apresenta um cenário mais desfavorável de adesão. (AU)


Subject(s)
Dental Prosthesis Repair , Air Abrasion, Dental , Shear Strength
9.
ImplantNewsPerio ; 2(6): 1033-1039, nov.-dez. 2017. tab
Article in Portuguese | LILACS, BBO | ID: biblio-880488

ABSTRACT

Objetivo: avaliar a força de mordida (FM) em pacientes com próteses sobre implantes. Material e métodos: neste estudo transversal, os pacientes foram recrutados entre junho e setembro de 2015. Foram selecionados indivíduos maiores de 18 anos e de ambos os sexos, portadores de reabilitação protética osseointegrada total parafusada, com período pós-operatório de seis meses e 12 meses, divididos em G1 (próteses bimaxilares sobre implantes) e G2 (prótese total inferior/convencional superior). Os pacientes foram instruídos para que mordessem durante dez segundos com o máximo da força possível em um dinamômetro digital. As medidas foram realizadas na face oclusal dos primeiros molares inferiores em ambos os lados, um de cada vez, e na região dos incisivos. Cada local foi mensurado três vezes e obtida uma média dos valores, com precisão de 0,01 N. Entre cada local de medida, respeitou-se um intervalo de dois minutos. Ainda, a dor (EAV), abertura bucal (mm) e a qualidade de vida (OHIP-14) foram mensuradas. Resultados: a dor no G1 foi 0, enquanto no G2 foi grau 3. Não houve diferença para o grau de abertura bucal (47,5 mm x 39,5 mm). As queixas (dor física, desconforto e incapacidade) foram registradas apenas no G2, sem diferença estatística). Entretanto, houve uma diferença signifi cativa entre G1 (275,80 N) e G2 (63,38 N) para a FM somente no lado direito (p=0,025). Conclusão: pacientes com próteses bimaxilares apresentam melhores escores em todos os parâmetros avaliados. Entretanto, mais estudos devem ser realizados em função das amostras serem reduzidas neste ensaio.


Objective: to evaluate the bite force (BF) in patients with dental implants. Material and methods: in this cross-sectional study, patients were recruited between June and September 2015. Individuals older than 18 years-old and of both sexes, who underwent osseointegrated prosthetic rehabilitations within a 6-12-month postoperative period, were divided in G1 (bimaxillary protheses) and G2 (total, implant-supported mandibular/conventional maxillary denture). Patients were instructed to bite for ten seconds with as much force as possible on a digital dynamometer. Measurements were made on the occlusal face of the fi rst lower molars on both sides, separately, and also in the incisor region. Each site was measured 3 times and an average was obtained with an accuracy of 0.01 N. Between each measurement site, an interval of two minutes was respected. Still, pain (VAS), buccal opening (mm), and quality of life (OHIP-14) were registered. Results: pain levels for G1 were 0 while in G2 a grade 3 was scored. There was no difference for the degree of buccal opening (47.5 x 39.5 mm). Complaints (physical pain, discomfort, and disability) were recorded only in G2, but without statistical difference. However, there was a signifi cant difference between G1 (275.80 N) and G2 (63.38 N) for BF only at the right side (p=0.025). Conclusion: patients with bimaxillary prostheses presented better scores for all tested parameters. However, further studies should be performed since sample sizes were reduced in this trial.


Subject(s)
Humans , Male , Female , Bite Force , Data Interpretation, Statistical , Dental Prosthesis, Implant-Supported , Denture, Complete , Mouth Rehabilitation , Prostheses and Implants
10.
Braz. dent. sci ; 19(3): 14-22, 2016. ilus
Article in English | LILACS, BBO | ID: biblio-830992

ABSTRACT

A literature review was performed including studies that evaluated the use of cleaning protocols for removable dentures through questionnaires, clinical trials, randomized clinical trials, and systematic reviews. Twenty studies were included and the results showed that bad preservation of the prostheses is mainly due to low knowledge about cleaning habits and methods. Also, a wide variety of effective cleaning methods were presented. However, there is no standard protocol for all patients and it should be customized for each patient. It is important to highlight that dentists should give adequate instructions concerning maintenance and hygiene of the prosthesis.


Uma revisão da literatura foi realizada incluindo estudos que avaliaram o uso de protocolos de limpeza para próteses removíveis através de questionários, ensaios clínicos, estudos clínicos randomizados e revisões sistemáticas. Vinte estudos foram incluídos e os resultados mostraram que a má preservação das próteses é principalmente devido ao baixo conhecimento sobre os hábitos e métodos de limpeza. Além disso, foram apresentados uma grande variedade de métodos de limpeza eficazes. No entanto, não existe um protocolo padrão para todos os pacientes, devendo ser personalizado para cada paciente. É importante destacar que os dentistas devem dar instruções adequadas quanto a manutenção e higiene das próteses.


Subject(s)
Humans , Dental Prosthesis , Oral Health , Oral Hygiene
11.
Arch. oral res. (Impr.) ; 9(1): 9-12, Jan.-Apr. 2013. ilus
Article in English | LILACS | ID: lil-754507

ABSTRACT

Forensic dentistry is finding increased application in identifying deceased individuals. Incorporating patient identification system in dentures is one of the measures taken in this regard. There are several denture identification measures, each having their own merits and demerits. This article describes a new denture identification system using Quick Response Code incorporated in dentures. This identification system can be very cost-effective, store lot of patient-related information and be easily accessible to the dentist...


A identificação de indivíduos falecidos é uma demanda crescente em Odontologia. A incorporação de sistemas de identificação na prótese total de pacientes é um procedimento de possível. Existem vários sistemas de identificação em próteses totais, cada um com seus próprios méritos e deméritos. Este artigo descreve um novo sistema de identificação de dentadura utilizando o código QR incorporado em próteses totais. Este sistema de identificação é de baixo custo, armazena grande quantidade de informações relacionadas ao paciente e é de fácil acesso ao dentista...


Subject(s)
Humans , Denture, Complete , Dental Informatics/methods , Forensic Dentistry/methods , Electronic Data Processing/methods , Reproducibility of Results , Technology, Dental/methods
12.
São José dos Campos; s.n; 2013. 91 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867554

ABSTRACT

O objetivo deste estudo foi avaliar a taxa de sobrevida, carga para fratura e distribuição de tensões de incisivos centrais e caninos superiores restaurados com facetas cerâmicas variando o desenho do preparo. Trinta incisivos centrais superiores e trinta caninos superiores (N=60) foram selecionados para o estudo. Os espécimes foram embutidos até 3 mm da junção cemento esmalte e o ligamento periodontal simulado usando um material a base de poliéter. Após essa etapa os espécimes foram randomizados em quatro grupos (n=15) de acordo com o desenho do preparo e o tipo de dente: Gr1- Incisivo central com preparo conservador; Gr2- Incisivo central com preparo convencional com chanfro palatino; Gr3- Canino com preparo conservador; Gr4 – Canino com preparo convencional com chanfro palatino. Os espécimes foram restaurados com facetas cerâmicas a base de di-silicato de lítio, obtidas pela técnica da injeção. Os espécimes foram submetidos à 4.106 ciclos mecânicos (45º, 37oC, 100 N, 4 Hz) e avaliados quanto a possíveis falhas a intervalos de 500.000 ciclos. Ao final da ciclagem mecânica os espécimes que sobreviveram foram submetidos ao teste de compressão. Modelos semelhantes aos utilizados no teste laboratorial foram simulados bi-dimensionalmente (Rhinoceros® 4.0) e o comportamento mecânico avaliado (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) através dos valores de Tensão Máxima Principal. As taxas de sobrevida dos corpos de prova foram calculadas pelo teste de Kaplan Meier e Log-rank (α=0.05) e os valores de carga para fratura pelo teste T-Student (α=0.05). Todos os grupos apresentaram taxas de 100 % de sobrevida, não havendo diferença estatística entre eles. O teste T-Student não mostrou diferença estatística para os diferentes desenhos de preparo, mas mostrou diferença para os diferentes dentes submetidos ao mesmo desenho de preparo. O teste de elementos finitos mostrou maior concentração de tensões de tração na faceta cerâmica para os grupos submetidos ao preparo com ...


The aim of this study was to evaluate the survival rate, load to fracture and tensile distribution of human central incisors and canines restored with ceramic veneers varying the prepare design. Thirty human central incisors and thirty canines (N=60) were selected for the study. The specimens were embedded with acrylic resin up to 3 mm of the cemento/enamel junction and the periodontal ligament was simulated with polyether. After this step the specimens were randomized in four groups (n=15), based on the tooth prepare design and type of teeth: Gr1- Central incisor with a conservative prepare; Gr2- Central incisor with conventional prepare with palatine chamfer; Gr3- Canine with conventional prepare; Gr4 - Canine with conventional prepare with palatal chamfer. The specimens were prepared, molded and models with rock stone type IV were obtained. Ceramic veneers (IPS e.max Press, Ivoclar Vivadent, Schann) were confectioned. The veneers were adhesively cemented on specimens. The specimens were submitted to mechanical cycling (45o, 37oC, 100 N, 4 Hz, 4.000.000 cycles) and evaluated at each 500.000 cycles to detect any kind of failure. Specimens that survive to mechanical cycling were submitted to fracture resistance test. Identical models were draw bi-dimensionally (Rhinoceros® 4.0) and the mechanical behavior were evaluated (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) by Maximum Principal Stress. The survival rate were evaluated by Kaplan-Meier test (α=0.05), while load to fracture values was evaluated by T-Student test (α=0.05). All groups showed same values of survival rate (100%). Same teeth showed same values of fracture load, independently the design of prepare. Different teeth, showed differences in the fracture load, when submitted to same design prepare. The laminate veneer with the palatal chamfer design showed higher Maximum Principal Stress values


Subject(s)
Ceramics , Dental Prosthesis , Dental Materials
13.
São José dos Campos; s.n; 2013. 91 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-870198

ABSTRACT

O objetivo deste estudo foi avaliar a taxa de sobrevida, carga para fratura e distribuição de tensões de incisivos centrais e caninos superiores restaurados com facetas cerâmicas variando o desenho do preparo. Trinta incisivos centrais superiores e trinta caninos superiores (N=60) foram selecionados para o estudo. Os espécimes foram embutidos até 3 mm da junção cemento esmalte e o ligamento periodontal simulado usando um material a base de poliéter. Após essa etapa os espécimes foram randomizados em quatro grupos (n=15) de acordo com o desenho do preparo e o tipo de dente: Gr1- Incisivo central com preparo conservador; Gr2- Incisivo central com preparo convencional com chanfro palatino; Gr3- Canino com preparo conservador; Gr4 – Canino com preparo convencional com chanfro palatino. Os espécimes foram restaurados com facetas cerâmicas a base de di-silicato de lítio, obtidas pela técnica da injeção. Os espécimes foram submetidos à 4.106 ciclos mecânicos (45º, 37oC, 100 N, 4 Hz) e avaliados quanto a possíveis falhas a intervalos de 500.000 ciclos. Ao final da ciclagem mecânica os espécimes que sobreviveram foram submetidos ao teste de compressão. Modelos semelhantes aos utilizados no teste laboratorial foram simulados bi-dimensionalmente (Rhinoceros® 4.0) e o comportamento mecânico avaliado (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) através dos valores de Tensão Máxima Principal. As taxas de sobrevida dos corpos de prova foram calculadas pelo teste de Kaplan Meier e Log-rank (α=0.05) e os valores de carga para fratura pelo teste T-Student (α=0.05). Todos os grupos apresentaram taxas de 100 % de sobrevida, não havendo diferença estatística entre eles. O teste T-Student não mostrou diferença estatística para os diferentes desenhos de preparo, mas mostrou diferença para os diferentes dentes submetidos ao mesmo desenho de preparo. O teste de elementos finitos mostrou maior concentração de tensões de tração na faceta cerâmica para os grupos submetidos ao preparo com...


The aim of this study was to evaluate the survival rate, load to fracture and tensile distribution of human central incisors and canines restored with ceramic veneers varying the prepare design. Thirty human central incisors and thirty canines (N=60) were selected for the study. The specimens were embedded with acrylic resin up to 3 mm of the cemento/enamel junction and the periodontal ligament was simulated with polyether. After this step the specimens were randomized in four groups (n=15), based on the tooth prepare design and type of teeth: Gr1- Central incisor with a conservative prepare; Gr2- Central incisor with conventional prepare with palatine chamfer; Gr3- Canine with conventional prepare; Gr4 - Canine with conventional prepare with palatal chamfer. The specimens were prepared, molded and models with rock stone type IV were obtained. Ceramic veneers (IPS e.max Press, Ivoclar Vivadent, Schann) were confectioned. The veneers were adhesively cemented on specimens. The specimens were submitted to mechanical cycling (45o, 37oC, 100 N, 4 Hz, 4.000.000 cycles) and evaluated at each 500.000 cycles to detect any kind of failure. Specimens that survive to mechanical cycling were submitted to fracture resistance test. Identical models were draw bi-dimensionally (Rhinoceros® 4.0) and the mechanical behavior were evaluated (MSC.Patrans 2005r2 e.MSC.Marc 2005r2) by Maximum Principal Stress. The survival rate were evaluated by Kaplan-Meier test (α=0.05), while load to fracture values was evaluated by T-Student test (α=0.05). All groups showed same values of survival rate (100%). Same teeth showed same values of fracture load, independently the design of prepare. Different teeth, showed differences in the fracture load, when submitted to same design prepare. The laminate veneer with the palatal chamfer design showed higher Maximum Principal Stress values.


Subject(s)
Ceramics , Dental Prosthesis , Dental Materials
14.
Arch. oral res. (Impr.) ; 7(3): 259-266, Sept.-Dec. 2011.
Article in English | LILACS, BBO | ID: lil-687439

ABSTRACT

Objectives: The aim of this study was to verify if there are poly (methyl methacrylate) (PMMA) absorptionand releasing of nystatin (NYS) and fluconazole (FLZ) after simulated treatment of oral candidosis. Materialsand methods: Specimens (30 × 25 × 5 mm) prepared with PMMA polymerized by hot water bath or microwaveenergy were immersed into NYS (3.12 μg/mL), FLZ (2.56 μg/mL) or deionized water (control) during14 days at 35 ± 2 °C. After treatment simulation, specimens were immersed into distilled water during 3, 7, 10and 14 days. The immersion liquid was changed after each analysis. Higher performance liquid chromatographywas used in order to detect antifungal compounds. In order to determine if there was surface depositionof drugs on PMMA resin, specimens were analyzed with electronic microscopy (SEM). Results: None of theantifungal agents was released from the PMMA resins. Conclusion: Within the limitations of this study, itcould be concluded that PMMA resins had no drug absorption with posterior release.


Objetivos: O objetivo deste estudo foi verificar se o poli (metil metacrilato) (PMMA) é capaz de absorver e liberar nistatina (NYS) e fluconazol (FLZ) após simular um tratamento para candidose oral. Materiais e métodos:Espécimes (30 × 25 × 5 mm) foram preparados em resina de PMMA por banho de água quente ou energia demicro-ondas e, em seguida, imersos em solução contendo NYS (3.12 μg/mL), FLZ (2.56 μg/mL) ou água deionizada(controle) durante 14 dias a 35 ± 2 °C. Após a simulação de tratamento, os espécimes foram imersos em água destilada durante 3, 7, 10 e 14 dias. O líquido de imersão foi trocado após cada análise. Cromatografia líquida de alta performance foi utilizada para detectar a presença dos agentes antifúngicos. Para determinar se houve deposição dos agentes antifúngicos na superfície de PMMA, os espécimes foram analisados por microscopia eletrônica de varredura(MEV). Resultados: Não houve liberação de agentes antifúngicos dos espécimes. Conclusão: Considerando as limitações deste estudo, pode-se concluir que a resina de PMMA não absorve ou libera agentes antifúngicos.


Subject(s)
Antifungal Agents/chemistry , Fluconazole/chemistry , Nystatin/chemistry , Polymethyl Methacrylate/chemistry , Absorption , Chromatography, High Pressure Liquid , Candida albicans , Candidiasis, Oral/drug therapy , Stomatitis, Denture/drug therapy , Materials Testing , Microscopy, Electron, Scanning , Dental Prosthesis/microbiology , Surface Properties , Time Factors
15.
Full dent. sci ; 2(6): 166-170, 20110816.
Article in Portuguese | LILACS, BBO | ID: biblio-850831

ABSTRACT

As coroas totalmente cerâmicas tem se tornado uma solução atrativa para fornecer reabilitação estética e funcional em dentes. O Sistema Procera® é atualmente um serviço restaurador dental que alia bom custo-benefício e alta qualidade. A proposta deste relato de caso foi ilustrar as vantagens deste sistema na reabilitação de dentes anteriores superiores. Uma paciente de 40 anos de idade se apresentou com a seguinte queixa: “desejo de melhorar a estética” dos incisivos centrais superiores com alteração de cor. Os dois incisivos centrais superiores foram preparados e coroas Procera® foram cimentadas. A qualidade do material e o potencial do sistema ajudou a resolver este caso restaurador com total confiança, tempo de trabalho reduzido e ótimo resultado estético


The all-ceramic crowns have become an attractive solution to provide functionaland esthetic rehabilitation on teeth. The Procera® system is currently providing cost-effective and high-quality dental restorative services. The purpose of this case report was to illustrate the advantages of this system for anterior rehabilitation. A 40-year-old patient presented with the chief complaint of “desire to improve esthetics” of discoloured upper central incisors. The two maxillary incisors were prepared and Procera Crowns were cemented. Material quality and the potential of this system helped resolve this restorative case with full confidence, reduced working-time, and optimum esthetic result


Subject(s)
Humans , Female , Adult , Ceramics , Tooth Crown , Esthetics, Dental , Incisor , Dental Prosthesis , Dental Restoration, Permanent
16.
RPG rev. pos-grad ; 18(1): 33-38, Jan.-Mar. 2011. tab, ilus
Article in Portuguese | LILACS | ID: lil-679735

ABSTRACT

The purposes of this study were to evaluate the rate of success of immediate or early loaded implants placed in congenital cleft alveolus in a reference Brazilian Public Service, and to investigate the probable causes of failures. All the immediately restoredosseointegrated implants installed from 1991 to 2010 at the Hospital for Rehabilitation of Craniofacial Anomalies (Bauru, SP, Brazil) were investigated. This search resulted in 281 patients, in whom 573 implants were installed. Only 10 fulfilled the following criteria: 1) single implants installed at the cleft alveolus (grafted or not) at least two years before the beginning of the study; 2) implants that had undergone to immediate or early load. Data about the patients and implants were collected from records of the patients and presented as percentage of well succeeded and failed implants. None of the implants failed. The implants have been in function for at least 58 months. Nine implants are in function for at least 5 years and one, for at least 10 years. It was concluded that rough surfaced titanium implants with proper dimensions installed in low density bone at the cleft region can receive immediate nonfunctional provisional restoration with satisfactory prognosis at medium and long-term as long as strict criteria is followed for case selection.


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Cleft Palate , Dental Implants , Dental Prosthesis , Periodontics
17.
RFO UPF ; 14(2): 139-142, maio-ago. 2009. tab, ilus
Article in English | LILACS | ID: lil-527871

ABSTRACT

The null hypothesis tested was that the glass slab temperature control by means of a liquid crystal thermometer attached during cements manipulation was acceptable. For this purpose, the glass slab temperature was verified by placing a liquid crystal thermometer on the lateral surface (LAT) and under the glass slab (CEN). An infrared thermometer (IRT) was used as a gold standard to the temperature measurement at the interval of 18 ºC to 24 ºC. The value of each measurement in ºC was recorded on 15 reference points marked on the glass slab and were repeated three times. The data was submittedto t-test (p = 0.05). The mean temperature recorded was 2.17 ºC higher for the LAT and 0.48 ºC for the CEN compared to the IRT. The differences showed statistical significance (p < 0.05). The null hypothesis must be accepted, as the liquid crystal thermometer placed below the glass slab provided a more accurate recording of thetemperature. It is concluded that the technique is an option to the glass slab with a thermometer attached.


A hipótese nula testada neste estudo foi a de que o controle de temperatura da placa de vidro com um termômetro de cristal líquido anexado durante a manipulação de cimentos seria um procedimento aceitável. Com este propósito, a temperatura da placa de vidro foi verificada posicionando-se um termômetro de cristal líquido na superfície lateral (LAT) e abaixo da placa (CEN). Um termômetro infravermelho (TIV) foi utilizado como padrão-ouro para a determinação da temperatura no intervalo de 18 oC a 24 oC. O valor de cada aferição em graus centígrados foi registrado em 15 pontos de referência marcados na placa de vidro, e as aferições foram repetidas três vezes. Os dados foram estatisticamente submetidos ao teste T (α = 0,05). A temperatura média registrada foi 2,17 oC maior no grupo LAT e 0,48 oC maior no grupo CEN em comparação ao TIV, sendo essas diferenças estatisticamente significativas (p < 0,05).A hipótese nula deve ser aceita, visto que o termômetro de cristal líquido posicionado abaixo da placa de vidro possibilitou um registro mais preciso da temperatura.Conclui-se que a técnica é uma opção para as placas de vidro com termômetro anexado.


Subject(s)
Cementation , Dental Cements , Dental Prosthesis
18.
RPG rev. pos-grad ; 15(3): 186-190, jul. -set. 2008. tab, ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-543741

ABSTRACT

Tensões ao implante e ao tecido ósseo peri-implantar podem causar reabsorção e perda de componentes. A magnitude das tensões pode variar com o uso pilares intermediários entre a prótese e os implantes. Assim, o objetivo deste trabalho foi verificar as tensões induzidas aos implantes quando submetidos ao torqueamento de infraestruturas protéicas com e sem o uso de pilar intermediário. Vinte infraestruturas em titâneo (n=10) foram obtidas por fundição a partir de matriz metálica contendo dois implantes, simulando prótese fixa de três elementos. Dez peças foram confeccionadas utilizando copings calcináveis tipo UCLA diretamente sobre os implantes. Outras dez foram confeccionadas sobre pilares cônicos intermediários para construções múltiplas. As tensões foram aferidas após o torqueamento de cada estrutura mediante o uso de extensômetros calibrados. A média de tensão no grupo UCLA foi 665,35 (173,99) gf e no grupo minipilar cônico foi 580,06 (253,93) gf. O teste t de Student foi utilizado para a comparação intergrupos. Não houve diferença estatística para os valores de tensão entre os dois grupos (p > 0,3924). O uso do pilar intermediário em infraestruturas de três elementos em Ti c.p. fundido não reduziu as tensões induzidas aos implantes.


Subject(s)
Dental Prosthesis , Dental Implants , Prosthesis Failure , Bone Screws , Dental Stress Analysis , Denture, Partial, Fixed , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL