1.
Rev. chil. cardiol ; 42(2)ago. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1515092

ABSTRACT

La taquicardia ventricular polimórfica se origina en los ventrículos, cuyos complejos QRS son de morfología, amplitud y dirección variable, con frecuencias que oscilan entre 200 y 250 lpm, pudiendo ser autolimitadas o degenerar en una fibrilación ventricular. La TdP es un tipo de taquicardia ventricular polimórfica caracterizada por complejos con un eje eléctrico que gira alrededor de la línea isoeléctrica y que está asociada a QT largo. Se presenta el caso de una paciente portadora de marcapaso que presenta episodios de taquicardia ventricular polimórfica, con una morfología típica de TdP, sin documentación de QT prolongado previo ni actual, generada por la estimulación ventricular sobre onda T, de forma accidental por desplazamiento del electrodo auricular a Ventrículo Derecho (VD).


Polymorphic ventricular tachycardia is a tachycardia originating in the ventricles, where the QRS complexes have variable morphology, amplitude, and direction, with frequencies ranging between 200 and 250 bpm; it may be self-limited or degenerate into ventricular fibrillation. Torsades de Pointes (TdP) is a type of polymorphic ventricular tachycardia characterized by complexes with an electrical axis that rotates around the isoelectric line and that is associated with long QT interval. We present the case of a patient with a pacemaker who presents episodes of polymorphic ventricular tachycardia, with a typical morphology of TdP, without documentation of previous or current prolonged QT, generated by ventricular stimulation on the T wave, accidentally due to displacement of the atrial electrode to the Right Ventricle (RV).

2.
Rev. colomb. cardiol ; 29(2): 240-243, ene.-abr. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1376885

ABSTRACT

Resumen El implante percutáneo de un electrodo de estimulación ventricular izquierdo a través del seno coronario para resincronización cardiaca siempre ha implicado un reto y más aún en pacientes con anatomía venosa coronaria compleja. Este caso demuestra cómo una técnica de doble canulación del seno coronario con uso de catéter multi-snare permite la colocación exitosa de un electrodo de estimulación ventricular izquierdo mediante acceso retrógrado a una vena posterolateral estenótica.


Abstract The percutaneous implantation of a left ventricular pacing electrode through the coronary sinus for cardiac resynchronization has always been a challenge, especially in patients with a complex coronary venous anatomy. This case shows how double cannulation of the coronary sinus using a multisnare catheter allows a left ventricular pacing electrode to be placed through retrograde access to a stenotic posterolateral vein, with a good clinical outcome.

3.
Vitae (Medellín) ; 28(2): 1-9, 2021-05-18. Ilustraciones
Article in English | LILACS, COLNAL | ID: biblio-1363202

ABSTRACT

Background: Despite the high reactivity of the platinum electrode, the iodine-coated platinum electrode shows obvious inertness toward adsorption and surface processes. For that, iodine-coated platinum electrodes accommodate themselves to interesting voltammetric applications. Objectives: This study reports using the modified iodine-coated polycrystalline platinum electrode as a voltammetric sensor for ascorbic acid determination in pharmaceutical formulations. Methods: The developed voltammetric method based on recording cyclic voltammograms of ascorbic acid at iodine-coated electrode The optimized experimental parameters for the determination of ascorbic acid were using 0.1 M KCl as a supporting electrolyte with a scan rate of 50mV/s. Results: The anodic peak related to ascorbic acid oxidation was centered at nearly 0.28V. An excellent and extended linear dependence of the oxidative peak current on the concentration of ascorbic acid was observed in the range 2.84x10-3 - 5.68 mM. The limit of detection (LOD) and limit of quantitation (LOQ) were 1.0 µM and 3.01 µM, respectively, attesting to the method's sensitivity. The investigation for the effect of potential interference from multivitamin tablet ingredients (vitamins B1, B6, B12, folic acid, citric acid, sucrose, glucose, and zinc) indicated specific selectivity toward ascorbic acid and the absence of any electrochemical response toward these components. Recovery results in the range 98.93±2.78 - 99.98±5.20 for spiked standard ascorbic acid in pharmaceutical formulations further confirmed the potential applicability of the developed method for the determination of ascorbic acid in real samples. Conclusions: The developed method was successfully applied to the analysis of ascorbic acid (vitamin C), and the obtained results were in good agreement with the labeled values; besides, the statistical tests indicated no significant difference at p=0.05 with a 95% confidence level


Antecedentes: A pesar de su alta reactividad, el electrodo de platino recubierto de yodo muestra una inercia evidente hacia la adsorción y los procesos superficiales. Por ello, los electrodos de platino recubiertos de yodo se adaptan a interesantes aplicaciones voltamétricas. Objetivos: Este estudio informa sobre el uso del electrodo de platino policristalino recubierto de yodo modificado como sensor voltamétrico para la determinación del ácido ascórbico en formulaciones farmacéuticas. Métodos: El método voltamétrico desarrollado se basa en el registro de voltamperogramas cíclicos del ácido ascórbico en el electrodo recubierto de yodo Los parámetros experimentales optimizados para la determinación del ácido ascórbico fueron utilizando KCl 0,1 M como electrolito de soporte con una velocidad de barrido de 50mV/s. Resultados: El pico anódico relacionado con la oxidación del ácido ascórbico se centró en casi 0,28V. Se observó una excelente y extendida dependencia lineal de la corriente del pico oxidativo con respecto a la concentración de ácido ascórbico en el rango 2,84x10-3 - 5,68 mM. El límite de detección (LOD) y el límite de cuantificación (LOQ) fueron 1,0 µM y 3,01 µM, respectivamente, lo que demuestra la sensibilidad del método. La investigación del efecto de la interferencia potencial de los ingredientes de las tabletas multivitamínicas (vitaminas B1, B6, B12, ácido fólico, ácido cítrico, sacarosa, glucosa y zinc) indicó una selectividad específica hacia el ácido ascórbico y la ausencia de cualquier respuesta electroquímica hacia estos componentes. Los resultados de recuperación en el rango de 98,93±2,78 - 99,98±5,20 para el ácido ascórbico estándar adicionado en formulaciones farmacéuticas confirmaron además la potencial aplicabilidad del método desarrollado para la determinación del ácido ascórbico en muestras reales. Conclusiones: El método desarrollado se aplicó con éxito al análisis de ácido ascórbico (vitamina C), y los resultados obtenidos coincidieron con los valores etiquetados; además, las pruebas estadísticas no indicaron diferencias significativas a p=0,05 con un nivel de confianza del 95%


Subject(s)
Humans , Drug Compounding , Cisplatin , Electrodes , Iodine
4.
Rev. costarric. cardiol ; 20(supl.1): 19-21, oct. 2018. graf
Article in Spanish | LILACS | ID: biblio-978341

ABSTRACT

Resumen Se presenta el caso de una paciente portadora de una miocardiopatía dilatada y marcapasos epicárdico unicameral im plantado por bloqueo atrioventricular completo, quien respondió favorablemente a la terapia de resincronización cardia ca; durante el seguimiento, requirió el implante de un nuevo electrodo del ventrículo izquierdo, el cual fue implantado a través de una vena posterior.


Abstract Dysautonomia and Chagas disease We present the case of a patient with a congenital dilated myocardiopathy and a single-chamber epicardic pacemaker, implanted by a complete atrioventricular block, who had a favorable response to cardiac resinchronisation therapy; during follow-up, she required a new left ventricle electrode which was implanted through a left posterior vein.


Subject(s)
Humans , Female , Adult , Cardiomyopathy, Dilated , Costa Rica , Electrodes , Atrioventricular Block , Cardiac Resynchronization Therapy , Heart Failure
5.
Rev. colomb. cardiol ; 25(2): 154-161, mar.-abr. 2018. tab, graf
Article in Spanish | LILACS, COLNAL | ID: biblio-959966

ABSTRACT

Resumen El síndrome de la plaqueta pegajosa en un trastorno cualitativo plaquetario en el que bajas concentraciones de epinefrina y adenosina difosfato producen hiperagregabilidad plaquetaria considerable. Se ha especulado mucho sobre la etiología de este trastorno sin que sean claros sus mecanismos fisiopatológicos. Desde el punto de vista clínico, se asocia a trombosis arteriales y venosas recurrentes en pacientes jóvenes, pérdidas gestacionales, otras complicaciones obstétricas y cefalea recurrente.En la literatura se ha descrito su presentación familiar, lo que hace sospechar su comportamiento hereditario autosómico dominante; también se ha reportado un fenotipo adquirido de la enfermedad en algunas poblaciones especiales como pacientes con enfermedad renal crónica en terapia de reemplazo renal o posterior al trasplante renal y en pacientes con cuadros inflamatorios o inmunosupresión. Se expone el caso de una paciente con antecedente de cefalea de difícil manejo, síndrome hipertensivo asociado al embarazo y mortinato, con síndrome del nodo enfermo y disautonomía manejadas con implantación de marcapasos definitivo bicameral con sensor CLS, que desarrolló trombosis de la vena subclavia, asociada al electrodo de marcapasos, recurrente a pesar de anticoagulación con warfarina y rivaroxabán e incluso a pesar de antiagregación con ácido acetilsalicílico, con posterior diagnóstico de síndrome de la plaqueta pegajosa.


Abstract Sticky platelet syndrome is a qualitative platelet disorder in which low concentrations of adrenaline and adenosine diphosphate produce considerable platelet hyperaggregability. There has been much speculation on the origin of this disorder as its pathophysiological mechanisms of action are not yet clear. From a clinical point of view, it is associated with recurrent arterial and venous thrombosis in young patients, miscarriages, other obstetric complications and recurrent headaches.Its familial presentation has been described in the literature, suspecting that it is of a dominant autosomal hereditary nature. An acquired phenotype of the disease has also been reported in some particular patients, such as patients with chronic kidney disease on renal replacement therapy or after a kidney transplant, as well as in patients with inflammatory processes or immunosuppression. The case is presented of a patient with a history of difficult to manage headaches, a hypertensive syndrome associated with the pregnancy, and a foetal death. She also had sick sinus node syndrome and dysautonomia managed with a definitive dual-chamber pacemaker with a CLS sensor. There was then a thrombosis in the subclavian vein associated with the pacemaker electrode, being recurrent despite anticoagulation with warfarin and rivaroxaban, and even despite anti-aggregation treatment with acetyl salicylic acid. She was subsequently diagnosed with sticky platelet syndrome.


Subject(s)
Epinephrine , Adenosine , Platelet Aggregation , Venous Thrombosis , Thrombosis , Biological Clocks , Electrodes
6.
Article in Spanish | LILACS | ID: biblio-1000369

ABSTRACT

INTRODUCCIÓN: Los implantes cocleares son dispositivos protésicos neuronales utilizados para el tratamiento de las hipoacusias neurosensoriales severas a profundas. La activación de electrodos estimula las células del ganglio espiral y las vías nerviosas. Una estimulación más discreta de subpoblaciones neuronales se puede obtener cuando los electrodos están más cerca de las células ganglionares en la pared del modiolo. La distancia del electrodo al modiolo podría ser una de las múltiples variables que influyen en el resultado del paciente con un implante coclear. Actualmente no hay un protocolo establecido para medir esta distancia. Mediante diversas técnicas de imágenes se puede determinar la posición de la guía de electrodos dentro de la cóclea. La tomografía computada cone beam ha sido validada como una herramienta útil para evaluar la posición de los electrodos luego de la implantación. Tykocinski et al. describieron un modelo de la interfase electrodo-electrolito del implante coclear como una resistencia y un condensador en paralelo, y la resistencia del tejido circundante como una resistencia en serie. Realizando un registro detallado de la forma de la curva de voltaje, los datos pueden usarse para calcular la impedancia clínica o total, la resistencia de acceso, la impedancia de polarización y sus subcomponentes: Resistencia de polarización y capacitancia de polarización. El objetivo de este estudio es determinar si la distancia electrodo modiolar de cada uno de los electrodos podría predecirse a partir de mediciones de impedancia...


INTRODUCTION: Cochlear implants are neuronal prosthetic devices used for the treatment of severe to profound sensorineural hearing loss. The activation of electrodes stimulates spiral ganglion cells and nerve pathways. A more discrete stimulation of neuronal subpopulations can be obtained when the electrodes are closer to the ganglion cells in the modiolus wall. The distance from the electrode to the modiolus could be one of the multiple variables that influence the outcome of the patient with a cochlear implant. Currently there is no established protocol to measure this distance. By means of various imaging techniques, the position of the electrode guide inside the cochlea can be determined. Cone beam computed tomography has been validated as a useful tool to evaluate the position of the electrodes after implantation. Tykocinski et al., described a model of the electrode-electrolyte interface of the cochlear implant as a resistance and a capacitor in parallel, and the resistance of the surrounding tissue as a series resistance. By making a detailed record of the shape of the voltage curve, the data can be used to calculate the clinical or total impedance, the access resistance, the polarization impedance and its subcomponents: polarization resistance and polarization capacitance. The objective of this study is to determine if the electrode distance modiolar of each of the electrodes could be predicted from impedance measurements…


INTRODUCÃO: Os implantes cocleares são dispositivos protéticos neuronais utilizados no tratamento da perda auditiva neurossensorial severa a profunda. A ativação de eletrodos estimula as células ganglionares espirais e as vias nervosas. Uma estimulação mais discreta de subpopulações neuronais pode ser obtida quando os eletrodos estão mais próximos das células ganglionares na parede do modíolo. A distância do eletrodo ao modíolo pode ser uma das múltiplas variáveis que influenciam o resultado do paciente com implante coclear. Atualmente não há protocolo estabelecido para medir essa distância. Por meio de várias técnicas de imagem, a posição do guia do eletrodo dentro da cóclea pode ser determinada. A tomografia computadorizada por feixe cônico foi validada como uma ferramenta útil para avaliar a posição dos eletrodos após o implante. Tykocinski et al. Descreveu um modelo da interface eletrodo-eletrólito do implante coclear como uma resistência e um capacitor em paralelo, e a resistência do tecido circundante como uma resistência em série. Realizando um registo detalhado da forma da curva de tensão, os dados podem ser usados para calcular a impedância clínico ou total, a resistência de acesso, a impedância de polarização e seus subcomponentes: resistência de polarização e capacitância de polarização. O objetivo deste estudo é determinar se a distância modiolar do eletrodo de cada um dos eletrodos poderia ser prevista a partir de medidas de impedância...


Subject(s)
Humans , Acoustic Impedance Tests , Electrodes, Implanted , Tomography, X-Ray Computed , Cochlear Implantation/methods , Cochlear Implantation/rehabilitation , Dimensional Measurement Accuracy
7.
Revista Digital de Postgrado ; 7(2): 40-44, 2018. ilus
Article in Spanish | LILACS, LIVECS | ID: biblio-1095439

ABSTRACT

Se presenta un caso de Taponamiento Cardíaco como complicación por retiro de electrodo epicárdico posterior a cirugía cardiaca. Se describe el caso de un paciente masculino de 55 años sometido a cirugía de revascularización miocárdica sin circulación extracorpórea. El postoperatorio inmediato transcurrió sin incidencias, siendo extubado a las 6 horas de la llegada a la unidad de cuidados intensivos (UCI). No requirió uso de inotrópicos ni hemoderivados. Ninguna alteración electrocardiográfica. A las 72 horas se retiraron los tubos de drenaje, así como el electrodo de estimulación transitoria ventricular epicárdico. A las dos horas el paciente comenzó a inestabilizarse hemodinámicamente. Mediante ecocardiografía transtorácica se evidenció un hematoma que comprimía la cara anterior de ventrículo derecho. Requirió exploración quirúrgica, reapertura esternal encontrando sangrado activo correspondiente al área de implante del electrodo epicárdico transitorio. La evolución posterior fue satisfactoria y el paciente fue dado de alta hospitalaria a los tres días siguientes. Los electrodos transitorios de estimulación cardiaca (ETEC) como el epicárdico, son usados en exceso en cirugía cardíaca y no están exentos de graves y fatales complicaciones. La cirugía coronaria sin circulación extracorpórea podría ofrecer una oportunidad para seleccionar adecuadamente a aquellos pacientes que van a necesitar estimulación cardíaca postoperatoria. Estudios prospectivos aleatorizados son necesarios para poder precisar los pacientes que realmente se beneficiarían de usar marcapasos epicárdicos transitorios(AU)


A case of cardiac tamponade by withdrawal epicardic electrode after a cardiac surgery was presented. A 55 years old male who underwent to a coronary artery by pass whithout extracorporeal circulation. The right now post ­ surgery elapse no incidents, extubado at 6 hours after arriving in the intensive care unit., Did not receive inotropics ,nor blood products .There was not alteration electrocardiographic. At 72 hours drainage tubes was removed, as well as the electrode transient epicardial ventricular stimulation. 2 hours the patient to become unstable hemodynamically. Throug transtoracic echocardiography it was shown a bruises that compresses the anterior aspect of the right ventricle. Requiered surgical exploration,sternal reopening, finding active bleeding corresponding to the area of the transient epicardiac electrode implant. The subsequent evolution was satisfactory and the patient was discharged after 3 days . The transient electrodes of cardiac stimulation (ETEC) like the epicardical ,they are widely used in cardiac surgery and they are not exempt from serious complications. Coronary surgery without extracorporeal circulatión could offer an opportunity to select properly those patiente who are going to need postoperative cardiac stimulation. Prospective randomized studies are necessary to be able to determine the patients who would really benefit from using transien epicardial pacemakers(AU)


Subject(s)
Humans , Male , Middle Aged , Cardiac Pacing, Artificial , Cardiac Tamponade , Electrodes , Myocardial Revascularization , Arrhythmias, Cardiac , Cardiology , Electrocardiography
8.
Medisan ; 20(10)oct. 2016. ilus
Article in Spanish | LILACS, CUMED | ID: lil-797510

ABSTRACT

Se presenta el caso clínico de un paciente de 52 años de edad que, a causa de una disfunción sintomática del nódulo sinusal, portaba un marcapasos permanente unicameral ventricular desde hacía 9 años, al cual se le había sustituido el generador por agotamiento de la batería. Un mes después del cambio el paciente acudió a la consulta especializada de Arritmias y Marcapasos en el Hospital Provincial Docente Clinicoquirúrgico "Saturnino Lora Torres" de Santiago de Cuba, por presentar síntomas de cansancio fácil, disnea, mareos y síncopes; se le indicaron electrocardiogramas de superficie que mostraron una conducción retrógrada ventriculoauricular y pseudofusiones. Teniendo en cuenta las manifestaciones clínicas y los hallazgos electrocardiográficos, se diagnosticó un síndrome de marcapasos y se decidió implantar un electrodo auricular y variar la modalidad de estimulación a la de doble cámara, como terapéutica efectiva para ello. Los síntomas desaparecieron y el paciente evolucionó favorablemente hasta su egreso de la institución hospitalaria.


The case report of a 52 years patient is presented that had a ventricular unicameral permanent pacemaker for 9 years, due to a symptomatic dysfunction of the synusal nodule. The pacemaker had dead battery and the generator was substituted. A month after the change the patient went to the Arrhytmias and Pacemaker specialized service at "Saturnino Lora Torres" Teaching Clinical Surgical Provincial Hospital in Santiago de Cuba, due to symptoms of easy tireness, dyspnea, dizziness and fainting fits; surface electrocardiograms were indicated that showed a ventriculoauricular retrograde conduction and pseudofusions. Taking into account the clinical features and the electrocardiographic findings, a pacemaker syndrome was diagnosed and it was decided to implant an auricular electrode and vary the stimulation modality to that of double camera, as effective therapy for it. The symptoms disappeared and the patient had a favorable clinical course when he was discharged from the hospital institution.


Subject(s)
Pacemaker, Artificial , Pacemaker, Artificial/adverse effects
9.
Int. j. morphol ; 34(2): 561-569, June 2016. ilus
Article in English | LILACS | ID: lil-787037

ABSTRACT

Femoral neuropathy associated with lower limb is treated by surgical intervention through activation/regeneration/grafting of nerve fibers by a nerve cuff electrode implant or neuro-prosthesis. These procedures require detailed and precise knowledge of neuro-anatomical variants of the femoral nerve and its fascicular anatomy so that the nerve injury can be investigated and treated more efficiently. The aim of the study is to uncover the variations both in the femoral nerve and its branches, to classify them and to bring out corresponding fascicular anatomy using a hypothesis based on the principle of consistency, continuity and traceability of fascicles. The study was carried out in the Department of Anatomy AIIMS Rishikesh using 13 matched lower limbs (26 femoral nerves) from 13 cadavers. The femoral nerve was exposed in the femoral triangle and traced to the posterior abdominal wall. Variations in the shape, size and course of the femoral nerve and its branches were analyzed. The fascicular arrangement was also conceptualized based on the hypothesis. Seven classes, high division, trunk anomaly, semi-scattered, scattered branching pattern, pectocutaneous, lateral cutaneous nerve of thigh and nerve to sartorius anomalies were detected. The corresponding fascicular organizations were modeled. The seven classes along with corresponding fascicular pattern will be very useful for neurosurgeons, radiologists, anesthetists and anatomists in diagnosis and treatment of femoral neuropathy.


La neuropatía femoral asociada con el miembro inferior es tratada por intervención quirúrgica a través de activación, regeneración e injerto de fibras nerviosas mediante un implante de electrodo de manguito de nervios o neuro-prótesis. Estos procedimientos requieren un conocimiento detallado y preciso de las variantes neuro-anatómicas del nervio femoral y su anatomía fascicular de modo que la lesión del nervio pueda ser investigada y tratada de manera más eficiente. El objetivo del estudio fue descubrir las variaciones tanto en el nervio femoral y sus ramas y clasificarlos a partir de la anatomía fascicular utilizando una hipótesis basada en el principio de la continuidad y trazabilidad de los fascículos correspondientes. El estudio se llevó a cabo en el Departamento de Anatomía AIIMS Rishikesh utilizando 13 miembros inferiores pareados (26 nervios femorales) de 13 cadáveres. El nervio femoral se expuso en el triángulo femoral y fue trazado en la pared abdominal posterior. Se analizaron las variaciones en la forma, tamaño y trayecto del nervio femoral y sus ramas. El patrón fascicular fue conceptulizado de acuerdo a la hipótesis planteada. Se detectaron anomalías clasificadas en: siete clases, división alta, anomalías de tronco, semi-dispersos, patrón de ramificación dispersa, pectocutáneo, nervio cutáneo lateral y nervio del músculo sartorio. Las clasificaciones junto con el patrón fascicular correspondientes serán de gran utilidad para los neurocirujanos, radiólogos, anestesistas y anatomistas en el diagnóstico y tratamiento de la neuropatía femoral.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Femoral Nerve/abnormalities , Lower Extremity/innervation , Anatomic Variation , Cadaver , Femoral Nerve/anatomy & histology , Lumbosacral Plexus/anatomy & histology
10.
Rev. colomb. ciencias quim. farm ; 44(3): 311-321, Sept.-Dec. 2015. ilus, graf, mapas, tab
Article in Spanish | LILACS | ID: lil-781918

ABSTRACT

La propiedad electroactiva de hidroquinona (HQ) se estudió sobre un electrodo de carbono vítreo modificado con quitosano, nanotubos de carbono de pared múltiple (Ch-MWCNT-GCE). La HQ se depositó a un potencial controlado sobre la superficie del electrodo y la oxidación de la HQ se midió por voltametría de onda cuadrada (SWV, por sus siglas en inglés). Se observó una corriente de oxidación a 0,39 V y una corriente de reducción a 0,21 V con un ΔV de 0,18 V; ello indicó un proceso reversible. Un aumento en las corrientes de oxidación y de reducción de casi 50% se observó cuando el Ch-MWCNT-GCE se recubrió con líquido iónico (LI). El electrodo se caracterizó por voltamperometría cíclica (CV, por sus siglas en inglés) en presencia y sin la presencia de diferentes líquidos iónicos con distinto anión, siendo el más óptimo el líquido iónico (LI) 1-butil-3-metilimidazolio hexafluorofosfato (BMIMPF6). Se estudiaron las variables experimentales como pH, tiempo de adsorción (t ads) y potencial de adsorción (Eads), así como también las potenciales interferencias. Bajo las óptimas condiciones (pH 3,0; t acc 60s; Eacc 0,10 V), el pico de la corriente es proporcional a la concentración de HQ entre 4,20 * 10-6 y 30,0 * 10-6 mol L-1, con un límite de detección de 2,45 * 10-7 mol L-1. La desviación estándar relativa para una solución que contiene 1,0 * 10-4 mol L-1 de HQ, fue de 1,5% para siete medidas iguales. El método se validó con una muestra de agua dopada con HQ.


Property of the electroactive hydroquinone (HQ) was studied on a glassy carbon electrode modified chitosan, multi wall carbon nanotubes (Ch-MWCNT-GCE). HQ is deposited at a controlled potential to the electrode surface and oxidation of HQ is measured by square wave voltammetry (SWV). An oxidation current to 0.39 V and a reduction current to 0.21 V with a 0.18 ΔV indicating a reversible process were observed. An increase in the flow of oxidation and reduction of almost 50% was observed when the Ch-MWCNT-GCE was coated with ionic liquid (LI). The electrode was characterized by cyclic voltammetry (CV) in the presence and without the presence of different ionic liquids with different anion being the most optimal ionic liquid (LI) 1-butyl-3-methyllimidazolio hexafluorophosphate (BMIMPF6). Experimental variables such as pH, adsorption time (TADs) and adsorption potential (Eads), as well as potential interference, were studied. Under optimal conditions (pH 3.0; t acc 60s; Eacc 0.10 V) the peak current is proportional to the concentration of HQ between 4.20 * 10-6 and 30.0 * 10-5 mol L-1 with a detection limit of 2.45 * 10-7 mol L-1. The relative standard deviation for a solution containing 1.0 * 10-4 mol L-1 HQ was 1.5% for seven equal measures. The method was validated with a water sample doped with HQ.

11.
Insuf. card ; 8(3): 142-148, set. 2013. ilus
Article in Spanish | LILACS | ID: lil-694736

ABSTRACT

La terapia de resincronización cardíaca (TRC) es un método terapéutico bien establecido para el tratamiento de pacientes con insuficiencia cardíaca. La TRC revierte la remodelación del ventrículo izquierdo (VI) dilatado en pacientes sintomáticos con una función sistólica deprimida y complejos QRS anchos, a pesar de recibir una terapia farmacológica óptima, mejorando la clase funcional y reduciendo tanto la sintomatología como la morbilidad, la mortalidad y la hospitalización. La proporción de pacientes que no responden a la TRC se estima en alrededor del 20-40%, según algunos estudios, asociándose a una tasa de complicaciones no despreciables, como son los desplazamientos de electrodos y la estimulación diafragmática. Estudios recientes sugieren que la TRC con un electrodo cuadripolar (EC) en el VI está asociada con excelentes umbrales de estimulación, bajas tasas de desplazamiento de estimulación del nervio frénico y mejora en el gasto cardíaco, en el seguimiento a corto y mediano plazo. Por último, serán necesarios estudios randomizados comparando EC con catéteres bipolares convencionales para evaluar la eficacia, complicaciones y el costo-eficacia.


Results of patients with cardiac resynchronization therapy using a quadripolar left ventricular lead Cardiac resynchronization therapy (CRT) is a well-established therapeutic for the treatment of patients with heart failure. CRT reverses remodelling of the dilated left ventricle (LV) and reduces morbidity and mortality in patients with symptomatic heart failure, prolonged electrical delay, and impaired systolic function receiving optimal pharmacological therapy, enhancing the functional class and reducing the symptoms and morbidity, mortality and hospitalization. The proportion of patients who do not respond to CRT is estimated at about 20-40%, according to some studies associated to a not insignificant complication rate, such as dislocation and phrenic nerve stimulation (PNS). Recent studies suggest that CRT with a quadripolar left ventricular (LV) lead results in excellent pacing thresholds, low rates of dislocation, PNS and improvement in cardiac output at short-term and at medium-term follow-up. Finally, it will be necessary quadripolar LV lead randomized trials comparing conventional bipolar catheter to assess the efficacy, complications and cost-effectiveness.


Resultados de pacientes com terapia de ressincronização cardíaca utilizando um eletrodo quadripolar no ventrículo esquerdo A terapia de ressincronização cardíaca (TRC) é uma abordagem terapêutica bem estabelecida para o tratamento de pacientes com insuficiência cardíaca. A TRC reverte remodelamento do ventrículo esquerdo (VE) em pacientes sintomáticos com função sistólica deprimida dilatada e complexos QRS largos, apesar de receber tratamento medicamentoso otimizado, melhorando a classe funcional e reduzindo os sintomas e a morbidade, mortalidade e hospitalização. A proporção de pacientes que não respondem a TRC é estimada em cerca de 20-40%, de acordo com alguns estudos, associado a uma taxa de complicação não insignificante, como o deslocamento de eletrodos e estimulação do nervo frênico (ENF). Estudos recentes sugerem que a TRC com eletrodo quadripolar (EQ) no VE está associada com excelentes limiares de estimulação, baixas taxas de deslocamento, ENF e melhor monitorização do débito cardíaco, a curto e médio prazo. Finalmente, serão necessários ensaios clínicos randomizados que comparam EQ com cateter bipolar convencional para avaliar a eficácia, as complicações e custo-efetividade.

12.
Univ. salud ; 13(2)dic. 2011.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1536961

ABSTRACT

El módulo de rehabilitación diseñado es un sistema compuesto por circuitos electrónicos para automatización y control de una órtesis robótica para mano, que colabora en la rehabilitación de la extremidad superior a nivel distal derecha de pacientes hemiparéticos con ataque cerebrovascular. La intencionalidad de movimiento es detectada a través de un sistema electrónico no invasivo de electromiografía, utilizando sensores ubicados sobre la piel (electrodos de superficie) que registran la actividad eléctrica de un músculo particular. El procesamiento de las señales adquiridas se realiza con un circuito de instrumentación acondicionado para manipular señales biológicas de pequeño voltaje. Una última etapa de procesamiento digital permite identificar el movimiento realizado. Cuando el paciente mueve su mano afectada, el sistema a su salida presenta una señal electromiográfica amplificada y sin componentes de ruido, que se utiliza como señal de control de los actuadores de la órtesis robótica automatizada para la mano derecha. El dispositivo diseñado contiene ejercicios para la extensión y flexión de la mano y para la extensión y oposición del pulgar.


The designed rehabilitation moduleis a system compound by electronic circuits to automate and control a robotic orthotic for a hand. It cooperates in the upper limb rehabilitation in the right distal zone of hemiparetic stroke patients. The motion intention is detected by a noninvasive electronic electromyography system using sensors (surface electrodes) placed in skin surface to report electrical activity of a single muscle. An instrumentation circuit is designed for signal processing of acquired signals based on low voltage bio-signals treatment. A latest digital processing section identifies the kind of movement.When the patient moves his or heraffected hand, the out of the system presents an amplified electromyography signal without noise components that is used like a control signal in the actuators of automated robotic orthotics for the right hand. The designed device contains flexion and extension exercises of the right hand and extension and opposition of the thumb.

13.
Article in Spanish | LILACS | ID: lil-627542

ABSTRACT

Objetivo: Comparar in vitro la cantidad de fluoruros liberados por los principales sellantes de puntos y fisuras basados en resina comercialmente disponibles en Latinoamérica. Material y Métodos: Se evaluó la liberación de fluoruros in vitro en tres sellantes fluorados de puntos y fisuras: Helioseal F (HF), Fissurit F (FF), Clinpro (CF) y Delton (D), sin flúor como control. Se utilizaron 28 discos de 12 mm de diámetro y 2 mm de espesor (n=7 por grupo). Las muestras fueron almacenadas en 5 ml de agua ultra de-ionizada con pH neutro a 37º C por 93 días. La liberación de fluoruros fue medida mediante un electrodo iónico selectivo a los 1, 2, 3, 8, 15, 28 y 93 días. Los datos fueron analizados con el test ANOVA y Tukey (p<0.05). Resultados: El patrón de liberación de flúor fue similar para los tres sellantes fluorados: una alta liberación durante las primeras 24 horas, que disminuyó bruscamente hacia el segundo día. Luego continuó con una disminución progresiva hasta el día 93. El primer día, FF liberó significativamente más fluoruros que HF. Entre los días 2 y 15 FF y HF liberaron significativamente más fluoruros que CF. Desde el día 28 en adelante, las diferencias de liberación de flúor no fueron significativas. Conclusión: El patrón de liberación de flúor in vitro es similar para los sellantes fluorados, con una elevada liberación durante los primeros dos días y luego, una marcada disminución en todos ellos. Este resultado podría explicar la falta de diferencias en la tasa de caries en pacientes tratados con sellantes de resina fluorados y no-fluorados observada en estudios clínicos.


Aim: To compare in vitro the amount of fluoride released from the main pit and fissure sealant resin-based on commercially available in Latin America. Materials and Methods: Twenty-eight samples of 12 x 2 mm were made from three commercial fluoridated resin-based sealants: Helioseal F (HF), Fissurit F (FF), Clinpro (CF) and without fluoride Delton (D), as a control. Samples were stored in 5 ml of deionized water at 37° C and neutral pH. Fluoride releases were measured at 1, 2, 3, 8, 15, 28 and 93 days with an ion-selective electrode. Data were analyzed using ANOVA and one-way and Tukey (p<0.05). Results: Fluoride-release profiles were similar for the three fluoridated sealants: a high release rates during the first 24 hrs and then a drastic drop. Afterward, they continued with a progressive decrease until day 93. The first day, FF release significantly more fluoride than HF. Between days 2 and 15, CF release significantly less fluoride than FF and HF, and later, there was no significant differences between sealants (p>0.05). Conclusion: The fluoride-release profile is similar for the fluoridated resin-based sealants under study: a high release during the first two days and afterwards, a very slow release. These results can explain the lack of differences in caries rate between fluoridated and non-fluoridated resin-based sealants observed in clinical trials.


Subject(s)
Cariostatic Agents/chemistry , Fluorides , Resins, Synthetic/chemistry , Pit and Fissure Sealants/chemistry , Analysis of Variance , Resin Cements/chemistry , Ion-Selective Electrodes , Materials Testing , Acrylic Resins/chemistry , Composite Resins/chemistry , Time Factors
14.
Acta otorrinolaringol. cir. cabeza cuello ; 39(3): 111-157, sept. 2011.
Article in Spanish | LILACS | ID: lil-605815

ABSTRACT

Comparar los diferentes grados del trauma en las estructuras anatómicas intracocleares luego de la inserción de tres diferentes electrodos erimodeolares insertados con dos tamaños diferentes de cocleostomías. Trauma valorado fluoroscópicamente y anatómico microscópico. Diseño del estudio. Estudio experimental con dos variables. Métodos. Se realizaron cocleostomías de 1.3 y 2 mm en 15 huesos temporales de cadáver, estos fueron implantados bajo visión fluoroscopia con uno de los siguientes electrodos perimodeolares: electrodo Nucleus 24 contur (Cochlear Implant System), electrodo Hi Focus Helix (Advanced Bionics), electrodo Combi 40 + (Medel). Se efectúan microcortes en 15 cócleas con el electrodo inserto, teniendo 3 cócleas como grupo control sin implantar. Cada cóclea fue analizada con otomicroscopio a un aumento 16x, valorando cualquier posible trauma durante la inserción. Resultados: Se encontraron tres diferentes grados de alteraciones observadas durante la inserción, en algunas fue solamente observada en la visión fluoroscópica; así mismo no se encontraron diferencias estadísticamente significativas entre el tipo de electrodo y el tamaño de la colostomía. Conclusiones: La inserción de los electrodos perimodeolares crean diferentes grados de trauma histomorfológicos en la cóclea; sin embargo, este modelo aunque es efectivo no es el óptimo para documentar los grados de lesión coclear. La visión fluoroscópica de la inserción puede proveer una ubicación inicial adecuada del lugar de la lesión. Al parecer no hay una relación directa entre lo observado fluoroscópicamente y los hallazgos anatómicos cocleares luego de analizar los microcortes. Significancia clínica del estudio: El implante in vitro de huesos temporales bajo visión fluoroscópica es una poderosa herramienta académica para el entrenamiento de cirujanos en el campo de la otología.


Problem addressed. To compare the different degrees of injury in the intracochlear structures using three different perimodiolar electrode arrays inserted and two sizes of cochleostomies. Study design. Experimental study with two variables. Methods. Cochleostomies of 1.3 and 2 millimeters were used in 15 temporal bones and then were implanted under fluoroscopic vision with one of the following perimodiolar electrode arrays: electrode nucleus 24 contour (Cochlear Implant System), electrode hi focus helix (Advanced Bionics), electrode combi 40 + (MED-EL). Micro slices of the 15 study cochleae with the electrode array in place and 3 more control cochleae were studied under 16x looking for any possible trauma during insertion. Results. There were different degrees of injuries observed during insertion, as well as some resistance documented under fluoroscopic vision in some of the temporal bones. However, there were no statistical differences either with the different type of electrodes or the different sizes of cochleostomy. Conclusions. Insertion of perimodiolar electrodes assumes some degree of histological cochlear injury. Nevertheless, the study model used was not the most favorable method to document the different degrees of intracochlear lesion. The video fluoroscopy during the insertion of the electrode array showed the possible location of the commencement of a supposed lesion. There was no concurrence between the video fluoroscopic findings and the location and degrees of intracochlear damage observed in the anatomical microcuts. Clinical significance of study. The in vitro insertion of a cochlear implant assisted by a videofluoroscopy could be considered a useful tool for surgeons in training.


Subject(s)
Cochlear Diseases/complications , Cochlear Implants/classification
15.
Rev. colomb. quím. (Bogotá) ; 40(2): 165-184, mayo.-ago. 2011.
Article in English | LILACS | ID: lil-636714

ABSTRACT

The electrochemical behavior of certain 1-(Toluenyl sulfonyl)-3-amino-4-(4'-substituted aryl hydrazono)-2-pyrazolin-5-ones were studied at the dropping mercury electrode by employing DC polarography. The variables that influence the electrode process were extensively studied. All compounds under investigation gave two well-defined polarographic waves. The mechanism for the electrode process was proposed in acid as well as in basic media.


El comportamiento electroquímico de ciertos 1-(Toluenil sulfonil)3-amino-4-(aril hidrazonio)-2-pirazolin-5-onas sustituidas fueron estudiados con un electrodo de gota de mercurio empleando polarografía de corriente directa. Las variables que influyen sobre el proceso en el electrodo fueron estudiadas ampliamente. Todos los compuestos estudiados presentaron dos ondas polarográficas bien definidas. Se propone un mecanismo para las reacciones electroquímicas estudiadas tanto en medio ácido como básico.


O comportamento eletroquímico de certos 1-(Toluenil sulfonil)3-amino-4-(aril hidrazonio)-2-pirazolin-5-onas substituídas foram estudados com um eletrodo de gota de mercúrio empregando polarografia de corrente direta. As variáveis que influem sobre o processo no eletrodo foram estudadas amplamente. Todos os compostos estudados apresentaram duas ondas polarograficas bem definidas. Propõe-se um mecanismo para as reações eletroquímicas estudadas tanto em meio ácido quanto em meio básico.

16.
Medisan ; 14(9): 2158-2163, 17&nov.-31-dic. 2010.
Article in Spanish | LILACS | ID: lil-585315

ABSTRACT

Se presenta el caso clínico de un anciano de 84 años, con antecedentes de cardiopatía isquémica crónica, que fue remitido a la consulta de cardiología (para atender a los pacientes con marcapasos y arritmias) del Hospital Provincial Docente Saturnino Lora de Santiago de Cuba, donde se le diagnosticó una disfunción sinusal y se le colocó un marcapasos permanente. Un mes después comenzó a presentar fiebre y otras manifestaciones clínicas de modo que reingresó por sospecha de endocarditis infecciosa aguda en la cavidad derecha, relacionada con la implantación del dispositivo intracardíaco, lo cual fue confirmado con los resultados de los hemocultivos y ecocardiogramas efectuados. El paciente evolucionó desfavorablemente y falleció


The case report of a 84 year-old elderly is presented, with history of chronic ischemic heart disease that was referred to the cardiology visit (to assist the patients with pacemakers and arrhythmias) of Saturnino Lora Teaching Provincial Hospital in Santiago de Cuba, where he was diagnosed a sinusal dysfuntion and he was inserted a permanent pacemaker. One month later he began to present fever and other clinical manifestations so that he was readmitted due to suspicion of acute infectious endocarditis in the right cavity, related to the placing of the intracardiac device, which was confirmed with the results of the hemoculture and echocardiograms. The clinical course of the patient was unfavorable and he died


Subject(s)
Humans , Male , Aged , Endocarditis, Bacterial , Heart Valves , Myocardial Ischemia , Pacemaker, Artificial , Secondary Care
17.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 23(2): 83-88, abr.-jun. 2010. tab, graf
Article in Portuguese | LILACS | ID: lil-559910

ABSTRACT

Grande parte do sucesso e eficácia de um sistema de estimulação cardíaca artificial é, diretamente, devido a performance dos eletrodos utilizados. Os eletrodos endocárdicos são também os itens que estão mais expostos à ação deletéria do agressivo ambiente em que são instalados. Na evolução técnica desses itens, observa-se principalmente: a facilidade de uso durante o implante; a otimização dos resultados paramétricos e a busca pela máxima confiabilidade. Assim, o presente trabalho compara o desempenho de duas gerações consecutivas de eletrodos bipolares endocárdicos de fixação ativa, da empresa Biotronil GmbH: os modelos Selox SR e Setrox S. Este estudo clínico envolveu 175 Setrox S(43 VVI e 66 DDD - 66 atriais e 109 ventriculares) e 79 Selox SR (SR VVI e 22 DDD - 22 atriais e 57 eletrodos ventriculares), no período de trinta e oito meses. Além dos parâmetros elétricos dos eletrodos...


Much of the success and effectiveness of an artificial cardiac pacing system is directly due to the performance of electrodes in use. The endocardial electrodes are also items that are mostexposed to any deleterious effects from the aggressive environment in which they are installed. It is observed in the technical evolution of these items, namely: the ease of use during the implantation, the optimization of electrical parameters and search for maximum reliability. Thus, this study compares the performance of two consecutive generations of bipolar endocardial electrodes of active fixation, from the company Biotronik GmbH: the models Selox SR and Setrox S. This clinical study involving 175 Setrox S (43 VVI and 66 DDD - 66 atrial and 109 ventricular) and 79 Selox SR (35 VVI and 22 DDD - 22 atrialand 57 ventricular leads) during the thirty-eight months. In addition to the electrical parameters of electrodes...


Gran parte del éxito y la eficacia de un sistema de estimulación cardiaca artificial se debe directamente al desempeño de los electrodos utilizados. Los electrodos endocárdicos son asimismo los componentes que están más expuestos a la acción deletérea del agresivo entorno en el que se los instala.En la evolución técnica de dichos componentes se advierte especialmente: la facilidad de manejo durante el implante; la optimización de los resultados paramétricos y la búsqueda por la máxima confiabilidad. De esa manera, el presente trabajo compara el desempeño de dos generaciones consecutivas de electrodos bipolares endocárdicos de fijación activa, de la empresa Biotronik GmbH: los modelos Selox SR y SetroxS. Este estudio clínico abarcó 175 Setrox S (43 VVI y 66 DDD - 66 auriculares y 109 ventriculares) y 79Selox SR (35 VVI y 22 DDD - 22 auriculares y 57 electrodos ventriculares), en el período de treinta y ocho meses. Además de los parámetros eléctricos de los electrodos...


Subject(s)
Humans , Female , Aged , Electrodes, Implanted/standards , Endomyocardial Fibrosis/diagnosis , Pacemaker, Artificial
18.
Rev. cuba. cir ; 49(1)ene.-mar. 2010. ilus
Article in Spanish | LILACS, CUMED | ID: lil-575494

ABSTRACT

Se presenta el primer caso de terapia de resincronización cardíaca (TRC) intervenido en el Hospital Hermanos Ameijeiras mediante técnica de cirugía torácica videoasistida. El paciente es un hombre de 67 años de edad, que presenta una miocardiopatía dilatada con disfunción sistólica ventricular izquierda grave. Al ingreso presentaba cuadro clínico de insuficiencia cardíaca avanzada, por lo que se consideró la indicación de TRC. Tras el fallo de la técnica percutánea para la colocación de un electrodo en una vena epicárdica del ventrículo izquierdo, se decidió el acceso quirúrgico de mínima invasión. El implante del electrodo epicárdico mediante cirugía torácica videoasistida fue un procedimiento seguro sin complicaciones transoperatorias ni posoperatorias. Hasta donde conocemos, esta es la primera ocasión en que se utiliza la videotoracoscopia en Cirugía Cardiovascular en Cuba(AU)


This is the first case of cardiac re-synchronization therapy (CRT) operated on the Hermanos Ameijeiras Clinical Surgical Hospital using video-assisted thoracic surgery. Patient is a man aged 67 presenting with a dilated myocardiopathy with severe left ventricular systolic dysfunction. At admission he showed a clinical picture of advanced cardiac insufficiency, thus, we considered the prescription of a CRT. After the failure of the percutaneous therapy for placing a electrode in a epicardiac vein of left ventricle, we decide the minimal invasive surgical approach. The epicardiac electrode implantation by thoracic surgery was a safe procedure without transoperative and postoperative complications. We have knowledge that this is the first time that a video-thoracoscopy in Cardiovascular Surgery is performed in Cuba(AU)


Subject(s)
Humans , Male , Aged , Thoracic Surgery, Video-Assisted/methods , Cardiac Resynchronization Therapy/methods , Heart Failure/surgery
19.
Int. j. morphol ; 28(1): 227-238, Mar. 2010. ilus
Article in Spanish | LILACS | ID: lil-579307

ABSTRACT

El comportamiento nervioso a la estimulación eléctrica ha sido ampliamente estudiado desde 1840, época en la que se comienza a entender las características de la amplitud de respuesta nerviosa y velocidades de conducción en nervios de animales. La amplitud de respuesta en segmentos de nervios es producto de los potenciales de acción compuestos resultantes a la estimulación eléctrica. En esta investigación se estudió el comportamiento nervioso a potenciales evocados in vivo en humanos (nervio ulnar) e in vitro como nervio aislado en Bufus marinus. Durante la estimulación de los nervios se encontró respuesta de comportamiento cualitativo creciente y heterogéneo intra e ínter-especie. El análisis de las respuestas y mecanismos que participan en estos resultados se discuten.


Nervous behaviour by electrical stimulation has been widely studied since 1840, times that initiated the comprehension of the conduction velocity and nerve's amplitude responses in animals. The amplitude response in nerve segments electrically stimulated is generated by the result of composed action potentials. This research pretended to study the nerve responses to evoked potentials in human in vivo (ulnar nerve) and in vitro in animals (Bufus marinus) in sciatic nerve. Electrical stimulation resulted in rising responses of heterogeneous quality inter and intra-species. Mechanisms involved in each response are examined.


Subject(s)
Humans , Animals , Bufo marinus/physiology , Humans/physiology , Ulnar Nerve/physiology , Reaction Time , Neural Conduction/physiology , Electric Stimulation , Electrodes
20.
Bol. méd. Hosp. Infant. Méx ; 62(1): 19-24, ene.-feb. 2005. tab
Article in English | LILACS | ID: lil-700739

ABSTRACT

Introduction. The most widely used method for applying fluoride (F-) topically is the fluoridated toothpaste. Its early use in large quantities is a risk factor for dental fluorosis. Objective: to determine the actual concentration of F in toothpastes sold in the Mexican market. Material and methods. Sixty-five different commercial toothpastes were analysed using the F ion-specific electrode technique. Results. The range of the F content was from 0 to 2 053 ppm. Of them, 16.92% were toothpastes for infant use (range= 0-1153 ppmF-). Mexican toothpastes had a mean of 879 ± 599.2 ppmF and imported toothpastes have a mean of 619.7 ppmF-; 54.5% of the infantile toothpastes presented F concentrations above 730 ppm and in 40% of the analyzed products, annotation on F content was found. Conclusions. Our results showed a wide variation in F concentration and suggest the need to implement policies to regulate the F concentration in these products. It is important that all the manufactured dentifrices show in the label and package the total F content of the product and the recommended doses will be printed, in order to prevent dental fluorosis.


Introducción. El método más usado para la aplicación tópica de flúor (F-)es la pasta dental fluorada. Su uso temprano en grandes cantidades es un factor de riesgo de fluorosis dental. Objetivo: conocer la concentración de P en las pastas dentales que se venden en México. Material y métodos. Se analizaron 65 pastas dentales usando la técnica del electrodo específico para fluoruros. Resultados. El contenido de fluoruro en la muestra analizada varió de 0-2053 ppm. De ellas, 16.92% fueron pastas para uso infantil (límite =0 -1153 ppmF-). Las pastas fabricadas en México tuvieron un promedio de 879 ± 599.2 ppmF-. Las pastas de origen extranjero tenían un promedio de 619.7 ppmF-; 54.5% de las pastas para niños presentaron valores de P superiores a 730 ppmF-. Solamente 40% de los productos analizados tenían impresa la concentración de P en las envolturas. Conclusiones. Nuestros resultados mostraron una amplia variación en la concentración de P. Esto sugiere que es necesario implementar medidas que regulen su concentración en dichos productos. Es importante que, para prevenir lesiones de fluorosis dental, los fabricantes de pastas dentales impriman en la etiqueta el contenido total de fluoruro y las dosis recomendadas.