Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Entramado ; 16(1): 230-238, ene.-jun. 2020. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1124738

RESUMO

Resumen Se evaluó estadísticamente la validez de cuatro métodos para determinar la Velocidad de Eritrosedimentación Globular (VSG) alternos al de Westergren, el que se tomó como "gold standard". Los métodos evaluados fueron Wintrobe (WB), Wintrobe inclinado (WI) a 45° y dos micrométodos capilares, uno vertical (MM) y otro inclinado a 45° (MMI). Se procesaron 419 muestras por los cinco métodos. Se evaluó la concordancia (C), la sensibilidad (S), especificidad (E), valor predictivo positivo (VPP) y valor predictivo negativo (VPN). Los resultados de S, E, VPP, VPN y C fueron: 93,8%, 93,6, 98,8%, 72,8% y 71% en el de WB; 86,3%, 85,7%, 97,2%, 52,4% y 54% en el de WI; 94,6%, 66,6%, 94,1%, 71,4% y 54% para MM y 91,9%, 72,4%, 94,8%, 60,8% y 55% para MMI. El índice kappa mostró una concordancia "buena" entre el método de Westergren y el método de Wintrobe y "moderada" con los métodos de WBI, MM y MMI. Los resultados del presente estudio muestran que el método de Wintrobe es confiable para su uso en el laboratorio clínico comparado con el de Westergreen.


Abstract Four methods were statistically evaluated for their validity to determine the alternative Erythrocyte sedimentation rate to that of Westergren, which was taken as the "gold standard". The methods evaluated were Wintrobe (WB), Wintrobe inclined (WI) at 45° and two capillary micromethods, one vertical (MM) and one inclined at 45° (MMI). A total of 419 samples were processed by the five methods. Concordance (C), sensitivity (S), specificity (E), positive predictive value (PPV) and negative predictive value (NPV) were evaluated. The results for S, E, PPV, NPV and C were: 93.8%, 93.6, 98.8%, 72.8% and 71% for WB; 86.3%, 85.7%, 97.2%, 52.4% and 54% for WI; 94.6%, 66.6%, 94.1%, 71.4% and 54% for MM and 91.9%, 72.4%, 94.8%, 60.8% and 55% for MMI. The kappa index showed "good" agreement between the Westergren method and the Wintrobe method and "moderate" agreement with the WBI, MM and MMI methods. The results of the present study show that the Wintrobe method is reliable for use in the clinical laboratory compared to the Westergren method.


Resumo Neste trabalho, foi avaliada estatisticamente a validez de quatro métodos para determinar a Velocidade de Eritrosedimentação Globular (VSG) alternos ao Westergren, que foi considerado como o "Método Padrão". Os métodos avaliados foram Wintrobe (WB), Wintrobe inclinado a 45° (WI) e dois micro-métodos capilares, um vertical (MM) e outro inclinado a 45° (MMI). 419 amostras foram processadas pelos cinco métodos. Envalou-se a concordância (C), sensibilidade (S), especificidade (E), assim como os valores preditivos positivos (VPP) e negativos (VPN). Os resultados de S, E, VPN e VPP foram: 93.8%, 93.6%, 98.8%, 72.8% e 71% com o WB; 86.3%, 85.7%, 97.2%, 52.4% e 54% com o WI; 94.6%, 66.6%, 94.1%, 71.4% e 54% para MM e 91.9%, 72.4%, 94.8%, 60.8% e 55% para o MMI. O índice kappa apresentou "boa" concordância entre os métodos de Westergren e Wintrobe, enquanto teve concordância "moderada" com os métodos WBI, MMe MMI. Os resultados deste estudo revelaram que o método de Wintrobe é confiável para seu uso no laboratório clínico comparado com o método de Westergren.

2.
R. bras. Parasitol. Vet. ; 29(4): e018020, out. 2020. tab
Artigo em Inglês | VETINDEX | ID: vti-29820

RESUMO

Canine leishmaniasis (CanL) is a disease caused by Leishmania infantum. Serological methods are the most common diagnostic techniques used for the diagnosis of the CanL. The objective of our study was to estimate the sensitivity and specificity of one in-house ELISA kit (ELISA UNIZAR) and three commercially available serological tests (MEGACOR Diagnostik GmbH) including an immunochromatographic rapid test (FASTest LEISH®), an immunofluorescent antibody test (MegaFLUO LEISH®) and an enzyme-linked immunosorbent assay (MegaELISA LEISH®), using latent class models in a Bayesian analysis. Two hundred fifteen serum samples were included. The highest sensitivity was achieved for FASTest LEISH® (99.38%), ELISA UNIZAR (99.37%), MegaFLUO LEISH® (99.36%) followed by MegaELISA LEISH® (98.49%). The best specificity was obtained by FASTest LEISH® (98.43%), followed by ELISA UNIZAR (97.50%), whilst MegaFLUO LEISH® and MegaELISA LEISH® obtained the lower specificity (91.94% and 91.93%, respectively). The results of present study indicate that the immunochromatographic rapid test evaluated FASTest LEISH® show similar levels of sensitivity and specificity to the quantitative commercial tests. Among quantitative serological tests, sensitivity and specificity were similar considering ELISA or IFAT techniques.(AU)


A leishmaniose canina (Lcan) é uma causada pela Leishmania infantum. Os métodos sorológicos são as técnicas diagnósticas mais utilizadas para o diagnóstico da leishmaniose canina. O objetivo do nosso estudo foi estimar a sensibilidade e a especificidade de um kit ELISA interno (ELISA UNIZAR) e de três testes sorológicos disponíveis comercialmente, feitos pelo mesmo fabricante (MEGACOR Diagnostik GmbH), incluindo um teste rápido imunocromatográfico (FASTest LEISH®), um teste de anticorpos imunofluorescentes (Megafluo LEISH®) e um ensaio de imunoabsorção enzimática (Megaelisa LEISH®), utilizando-se modelos de classe latentes numa análise bayesiana. Foram incluídas duzentas e quinze amostras de soro. A maior sensibilidade foi alcançada para Fastest LEISH® (99,38%), ELISA UNIZAR (99,37%), Megafluo LEISH® (99,36%) seguida por Megaelisa LEISH® (98,49%). A melhor especificidade foi obtida por FASTest LEISH® (98,43%), seguida por ELISA UNIZAR (97,50%), enquanto Megafluo LEISH® e Megaelisa LEISH® obtiveram a menor especificidade (91,94% e 91,93%, respectivamente). Os resultados do presente estudo indicam que o teste rápido imunocromatográfico, avaliado por FASTest LEISH® mostra níveis similares de sensibilidade e especificidade aos testes comerciais quantitativos incluídos. Entre os testes sorológicos quantitativos, a sensibilidade e a especificidade foram semelhantes, considerando-se as técnicas de ELISA ou IFI.(AU)


Assuntos
Animais , Cães , Sorologia , Leishmaniose/diagnóstico , Cães/microbiologia , Teorema de Bayes
3.
Rev. bras. parasitol. vet ; 29(4): e018020, 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1144232

RESUMO

Abstract Canine leishmaniasis (CanL) is a disease caused by Leishmania infantum. Serological methods are the most common diagnostic techniques used for the diagnosis of the CanL. The objective of our study was to estimate the sensitivity and specificity of one in-house ELISA kit (ELISA UNIZAR) and three commercially available serological tests (MEGACOR Diagnostik GmbH) including an immunochromatographic rapid test (FASTest LEISH®), an immunofluorescent antibody test (MegaFLUO LEISH®) and an enzyme-linked immunosorbent assay (MegaELISA LEISH®), using latent class models in a Bayesian analysis. Two hundred fifteen serum samples were included. The highest sensitivity was achieved for FASTest LEISH® (99.38%), ELISA UNIZAR (99.37%), MegaFLUO LEISH® (99.36%) followed by MegaELISA LEISH® (98.49%). The best specificity was obtained by FASTest LEISH® (98.43%), followed by ELISA UNIZAR (97.50%), whilst MegaFLUO LEISH® and MegaELISA LEISH® obtained the lower specificity (91.94% and 91.93%, respectively). The results of present study indicate that the immunochromatographic rapid test evaluated FASTest LEISH® show similar levels of sensitivity and specificity to the quantitative commercial tests. Among quantitative serological tests, sensitivity and specificity were similar considering ELISA or IFAT techniques.


Resumo A leishmaniose canina (Lcan) é uma causada pela Leishmania infantum. Os métodos sorológicos são as técnicas diagnósticas mais utilizadas para o diagnóstico da leishmaniose canina. O objetivo do nosso estudo foi estimar a sensibilidade e a especificidade de um kit ELISA interno (ELISA UNIZAR) e de três testes sorológicos disponíveis comercialmente, feitos pelo mesmo fabricante (MEGACOR Diagnostik GmbH), incluindo um teste rápido imunocromatográfico (FASTest LEISH®), um teste de anticorpos imunofluorescentes (Megafluo LEISH®) e um ensaio de imunoabsorção enzimática (Megaelisa LEISH®), utilizando-se modelos de classe latentes numa análise bayesiana. Foram incluídas duzentas e quinze amostras de soro. A maior sensibilidade foi alcançada para Fastest LEISH® (99,38%), ELISA UNIZAR (99,37%), Megafluo LEISH® (99,36%) seguida por Megaelisa LEISH® (98,49%). A melhor especificidade foi obtida por FASTest LEISH® (98,43%), seguida por ELISA UNIZAR (97,50%), enquanto Megafluo LEISH® e Megaelisa LEISH® obtiveram a menor especificidade (91,94% e 91,93%, respectivamente). Os resultados do presente estudo indicam que o teste rápido imunocromatográfico, avaliado por FASTest LEISH® mostra níveis similares de sensibilidade e especificidade aos testes comerciais quantitativos incluídos. Entre os testes sorológicos quantitativos, a sensibilidade e a especificidade foram semelhantes, considerando-se as técnicas de ELISA ou IFI.


Assuntos
Animais , Cães , Testes Sorológicos/normas , Leishmaniose/diagnóstico , Leishmaniose/veterinária , Leishmania infantum/imunologia , Doenças do Cão/diagnóstico , Análise de Classes Latentes , Ensaio de Imunoadsorção Enzimática/normas , Ensaio de Imunoadsorção Enzimática/veterinária , Testes Sorológicos/veterinária , Anticorpos Antiprotozoários/sangue , Teorema de Bayes
4.
Braz. dent. sci ; 22(2): 178-189, 2019. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-996378

RESUMO

Objective: The present study aimed to explore the existence of golden proportion (GP) between the widths of maxillary anterior teeth and golden standard (GS) for width to height ratio of maxillary central incisor in individuals with attractive and non-attractive smiles. Material and Methods: A total 82 females were recruited and divided into 2 groups: attractive smile (n=41) and non-attractive smile (n=41). Frontal photographs were taken, scanned, and saved in a personal computer. The apparent mesiodistal width of each anterior tooth was measured. The data were analyzed using the appropriate statistical tests at a P-value of 0.05). Conclusion: Frequency of the golden proportion was very low among the study population. Smile attractiveness was not greatly related to the proportions between the teeth. (AU)


Objetivo: O presente estudo teve como objetivo explorar a existência de proporção áurea (GP) entre as larguras dos dentes anteriores superiores e padrão-ouro (GS) para a relação largura-altura do incisivo central superior em indivíduos com sorrisos atraentes e não atraentes. Material e Métodos: Foram recrutadas 82 mulheres, divididas em 2 grupos: sorriso atraente (n = 41) e sorriso não atraente (n = 41). Fotografias frontais foram tiradas, digitalizadas e salvas em um computador pessoal. A largura aparente mesiodistal de cada dente anterior foi medida. Os dados foram analisados por meio dos testes estatísticos apropriados, com valor de p 0,05). Conclusão: A frequência da proporção áurea foi muito baixa na população estudada. Atratividade de sorriso não foi fortemente relacionada com as proporções entre os dentes. (AU)


Assuntos
Humanos , Feminino , Sorriso , Dente , Estética Dentária
5.
Rio de Janeiro; s.n; 2017. 81 p.
Tese em Português | LILACS, Coleciona SUS | ID: biblio-1151981

RESUMO

The prediction of meniscus reparability is quite useful for surgeons to optimize surgical planning. The main objective of this study was to evaluate the ability of magnetic resonance imaging (MRI) to predict the suture of meniscal lesions. This was an unicentric retrospective study that included 104 patients who underwent knee joint ligament reconstruction and / or arthroscopy for the treatment of meniscal injury at knee joint level. The MRI images of the meniscus were evaluated and later the arthroscopic findings were used as the gold standard. After the operative procedure, the cases were allocated into two groups according to the necessity of meniscus suture: Sutured Group "MSu" (n = 58) and Non sutured Group "MNSu" (n = 150). Considering the lesion detection capacity in the medial meniscus, the sensitivity, specificity and accuracy of MR were 85.3%, 63.9% and 77.9%, respectively. The positive predictive value (PPV) was 81.7% and the negative predictive value (NPV) was 69.7%. The agreement between MRI and arthroscopy was moderate. For the lateral meniscus, sensitivity, specificity and accuracy of MRI were 80.6%, 89.0% and 86.5%, respectively, with PPV of 75.7% and NPV of 91.5% and a substantial agreement. Regarding suture predictability, the sensitivity, specificity and accuracy were respectively 60.3%, 66.7% and 64.9% with PPV of 41.2% and NPV of 81.3%, with weak agreement. According to the arthroscopy, the 58 meniscal lesions of the MSu group were more frequent in the posterior horn, had the longitudinal pattern and were located in the red-red vascular zone. In our study, MRI was not a good predictor of meniscal suture, although it is an useful tool for the diagnosis of medial and lateral meniscal lesions


Assuntos
Meniscos Tibiais/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética
6.
J. health inform ; 8(supl.I): 1031-1040, 2016. ilus
Artigo em Português | LILACS | ID: biblio-906773

RESUMO

A utilização de técnicas de Processamento de Linguagem Natural (PLN) em textos clínicos é amplamente dependente de grandes quantidades de dados textuais anotados, denominados corpus ou padrão ouro. Sendo essenciais para a modelagem da linguagem durante a fase de treinamento de diversos algoritmos de PLN. Porém, para a criação de um padrão ouro é necessário um extenso e custoso trabalho manual de anotação, que demanda um grande esforço de especialistas. OBJETIVO: Realizar uma revisão da literatura, visando o estudo de metodologias e ferramentas utilizadas em procedimentos de anotação de textos. MÉTODO: Levantamento em bases científicas referentes à elaboração de corpus morfológicos, sintáticos e morfossintáticos foi realizado, analisando 32 estudos de anotação e mais 12 ferramentas. RESULTADOS: Foram levantados os principais aspectos nos processos de anotação, bem como realizada uma avaliação dentre critérios pré-definidos de cada das ferramentas de suporte encontradas.


The use of natural language processing techniques (NLP) in clinical texts is dependent on large amounts of annotated text data, called corpus or gold standard. Are essential for the modelling language during the training phase of NLP algorithms. However, for the creation of a gold standard is required extensive and costly manual annotation task, that demands a great deal of experts. OBJECTIVES: To review the literature to identify methodologies and tools applied to text annotation. METHODS: Scientifics databases search regarding the development of morphological, syntactic and morphosyntactic corpus was performed by analyzing 32 annotation studies and 12 tools. RESULTS: Main aspects of the annotation process description, as well as an assessment from pre-defined criteria for each one of the annotation tools identified.


Assuntos
Humanos , Processamento de Linguagem Natural , Software , Armazenamento e Recuperação da Informação , Congressos como Assunto
7.
Natal; s.n; dez. 2013. 78 p. (BR).
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-866712

RESUMO

As disfunções temporomandibulares (DTM) representam a maior causa de dor não dentária da região orofacial. Dada sua alta prevalência na população em geral e a existência de inúmeros instrumentos diagnósticos não padronizados, buscou-se elaborar e validar um questionário simples, de acessibilidade ampla e aplicação prática, com vistas a contribuir para o diagnóstico e o estudo epidemiológico das mesmas. A estratégia utilizada na montagem do instrumento foi estabelecida com base na avaliação criteriosa de questionários já existentes na literatura, validação de expertos na área de DTM, validação fatorial, de face (na primeira fase do estudo) e, frente ao padrão ouro (RDC/TMD), na segunda fase do estudo. Na primeira fase, participaram 160 indivíduos. A consistência interna resultou num Coeficiente Alfa de Cronbach de 0,752 para o questionário com sete itens; enquanto que para o questionário com cinco itens, este resultado foi de 0,694, não sendo o mesmo, considerado baixo por avaliar apenas cinco questões e ainda, em razão do tema central da pesquisa ser bastante subjetivo. A análise fatorial confirmatória apontou para uma variância total dos fatores extraídos do questionário com sete itens, de 58,2 % e do questionário com cinco itens de 70,04%. Portanto, o questionário com cinco questões, apresentou resultados estatísticos superiores ao de sete questões. Na validação frente ao padrão ouro (RDC/TMD), foram avaliados 99 indivíduos tendo sido testados os dois questionários, com sete e com cinco questões. Na estrutura com sete questões, ao se categorizar as mesmas por totais de pontos obtidos, em quatro condições, obteve-se o melhor resultado quando se considerou com DTM a faixa entre 10 e 21 pontos, sendo 85,1% positivos também no RDC/TMD, com acurácia de 90,1% e Kappa 0,817. Nesta condição, a sensibilidade encontrada foi de 95% (IC 95%, 91 a 99), especificidade de 87% (IC 95%, 81 a 93), VPP 85%, VPN 96%, LR+ 7,3 e LR- 17,4. Quando os dados foram avaliados para o questionário com cinco questões (QST/DTM), pode-se observar que o melhor ponto de corte foi quando se considerou como portadores de DTM, os indivíduos na faixa entre 7 e 15 pontos, com acurácia de 85,8% e Kappa 0,817. Nesta condição, a sensibilidade foi 88% (IC 95%, 81,6 a 94,4), especificidade 84% (IC 95%, 76,8 a 91,2), VPP 80%, VPN 90,5%, LR+ 5,5 e LR- 7,0. A simplicidade do presente questionário (QST/DTM) com apenas cinco questões, possibilita seu uso como elemento de triagem inicial na área da dor orofacial em disfunção temporomandibular, com boa compreensibilidade, confiabilidade, reprodutibilidade e possibilidade de aplicação em pesquisas epidemiológicas. Concluiu-se que o questionário aqui validado, permite sua aplicação de forma simples tanto por profissionais e pesquisadores da Odontologia como de outras áreas da saúde. (AU)


Temporomandibular disorders (TMD) represent the biggest cause of non-dental pain in the orofacial region. In reason of its high prevalence in the general population and the existence of numerous non-standardized diagnostic tools, it was sought to develop and validate a simple questionnaire, with wide accessibility and practical application, in order to contribute to the diagnosis and epidemiological study of the same. The strategy used in the assembly of the instrument was based on careful evaluation of existing questionnaires in the literature, validation of experts in the field of TMD, face and factorial validity (at the first moment of the study) and validation against the gold standard (RDC/TMD), at the second moment of the study. At the first stage, participated 160 individuals. The internal consistency resulted in a Cronbach alpha of 0,752 for the questionnaire with seven items, while for the questionnaire with five items, this result was 0,694, not being the same considered a low value since it evaluated only five questions and yet, in reason of the subjectivity of the main theme of the research. Confirmatory factor analysis indicated a total variance of the factors extracted from the questionnaire with seven items of 58,2% and for the questionnaire with five items of 70,04%. Therefore, the questionnaire with five questions presented better statistical results them the one with seven questions. In the validation against the gold standard (RDC/TMD), 99 individuals were evaluated, being tested both questionnaires, with five and seven questions. In the structure with seven issues, when categorizing them by total points earned, on four conditions, we obtained the best result when considering with TMD the range between 10 and 21 points, being 85,1% positive also in the RDC/TMD, with an accuracy of 90,1% and Kappa 0,817. In this condition, the sensitivity was 95% (CI 95%, 91 to 99), specificity of 87% (CI 95%, 81 to 93), PPV 85%, NPV 96%, LR+ 7,3 and LR- 17,4. When the data were evaluated for the questionnaire with five questions (QST/DTM), one can observe that the best cutoff point was when considered as with TMD the individuals aged between 7 and 15 points, with an accuracy of 85,8% and 0,817 Kappa. In this condition, the sensitivity was 88% (CI 95%, 81,6 to 94,4), specificity 84% (CI, 95%, 76,8 to 91,2), PPV 80%, NPV 90,5%, LR+ 5,5 and LR- 7,0. The simplicity of this questionnaire (QST/DTM) with only five issues permits its use as an initial screening in the area of orofacial pain in temporomandibular disorders, with good responsiveness, reliability, reproducibility and possibility of application in epidemiologic researches. It was concluded that the questionnaire here validated, enables its application in a simple manner by both practitioners and researchers of Dentistry as in other areas of health. (AU)


Assuntos
Articulação Temporomandibular/patologia , Medição da Dor , Inquéritos e Questionários/normas , Transtornos da Articulação Temporomandibular/diagnóstico , Transtornos da Articulação Temporomandibular , Estudos Observacionais como Assunto , Tomografia Computadorizada por Raios X
8.
J. pediatr. (Rio J.) ; J. pediatr. (Rio J.);85(1): 84-86, jan.-fev. 2009. tab
Artigo em Inglês, Português | LILACS | ID: lil-507704

RESUMO

OBJETIVO: O monitoramento do pH esofágico é considerado o método mais confiável para diagnosticar o refluxo gastroesofágico. No entanto, a interpretação do mesmo estudo de pH pode diferir entre observadores. Neste estudo, investigamos as causas e o grau de variabilidade entre observadores. MÉTODOS: Este estudo retrospectivo incluiu todas as crianças (n = 72) que realizaram monitoramento de pH durante 1 ano no Maxima Medical Centre, em Veldhoven, Holanda. RESULTADOS: Foi encontrada uma variabilidade de 18 por cento entre observadores. A variabilidade foi causada por diferenças de opinião sobre a duração do registro, dúvidas sobre a posição da sonda, artefatos e flutuação do pH de base. CONCLUSÕES: A maioria desses problemas pode ser eliminada por avaliação da posição do eletrodo de pH e calibração pós-teste. No entanto, ainda falta uma definição clara dos artefatos de monitoramento. Este estudo mostra que a concordância mútua na interpretação dos estudos de pH foi regular (coeficiente kappa de 0,70).


OBJECTIVE: To investigate the causes and degree of interobserver variability in esophageal pH monitoring for the diagnosis of gastroesophageal reflux. METHODS: This retrospective study included all children (n = 72) who underwent pH monitoring during 1 year at Maxima Medical Centre in Veldhoven, the Netherlands. RESULTS: An interobserver variability of 18 percent was found. Variability was caused by differences in opinion about the duration of registration, doubts about probe position, artifacts and drift of baseline pH. CONCLUSIONS: Most of these problems can be eliminated by posttest calibration and assessment of the pH electrode position. However, a clear definition of monitoring artifacts is lacking. This study shows that mutual agreement in the interpretation of pH studies was fair (kappa coefficient of 0.70).


Assuntos
Feminino , Humanos , Lactente , Masculino , Monitoramento do pH Esofágico/estatística & dados numéricos , Refluxo Gastroesofágico/diagnóstico , Calibragem/normas , Eletrodos Implantados/normas , Variações Dependentes do Observador , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA